Desoutter 6151657310 Скачать руководство пользователя страница 13

EN

Operation

06/2020

13 / 24

How to read the tightening report

LED color

Description

Action to do

Green

Accept report

None

Yellow

Incomplete rundown

Tighten again.

Yellow and red (orange)

Reject report

Loosen and tighten again.

Red

Above max. limits

Remove and replace the fastener.

How to reverse the rotation

1

Run reverse button

Press this button.

Red and green LEDs are blinking alternatively.

Apply the tool to the fastener and press the trigger.

How to smooth the tool stop

The "Ergostop" function must be disabled for tightening tests or certification on tightening benches.

Ergostop allows a smoother tool stop to reduce the torque reaction on the operator.
When delivered, this function is disabled.

Go to the main screen.

Press this button during 2 seconds.

Go to 

Ergostop

. Use the buttons to enable or disable the function, save and validate.

How to wake up EAB tools

The tool display switches off automatically after 2 minutes of inactivity.

Press the trigger.

The tool powers off after 30 minutes of inactivity.
Long press the reverse button.

Refer to "Power off" configurable on the tool display.

Unplug and plug the battery pack.

Results monitoring

Connect the tool to a PC by using the eDOCK device.

Содержание 6151657310

Страница 1: ...6151657340 EAB 50 450 6151657350 EAB 60 370 6151657360 EAB 75 300 6151657370 EAB 95 240 6151657380 Download the latest version of this document at http www desouttertools com info 6159929380_EN WARNING Read all safety warnings and instructions Failure to follow the safety warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future...

Страница 2: ...g Instructions 11 How to use the tool 11 Results monitoring 13 Service 15 Firmware version on tool display 15 Tool information from tool display 15 Tool test with CVIMONITOR 15 Tool identification with CVIMONITOR 15 Maintenance Instructions 15 Instructions for transducerized tools 15 Read before maintenance 15 Preventive Maintenance 16 Service alarm on tool display 16 Calibration via tool display ...

Страница 3: ... operation hours or otherwise The product warranty relies on the correct use maintenance and repair of the tool and its component parts Damage to parts that occurs as a result of inadequate maintenance or performed by parties other than Desoutter or their Certified Service Partners during the warranty period is not covered by the warranty To avoid damage or destruction of tool parts service the to...

Страница 4: ... product see the Dimensional drawings archive https www desouttertools com resource centre Overview General overview EAB tools are cordless angle head nutrunners They are hand held by the operator and powered by a Desoutter battery pack On delivery the tool display is protected by a password Tools are delivered with 1 Pset The target torque is configurable from the tool display The last 100 result...

Страница 5: ...EABA EABC Torque range Nm Model Min Nominal Max EABx 15 900 5 13 15 EABx 26 560 5 24 26 EABx 32 410 7 30 32 EABx 45 330 9 40 45 EABx 50 450 9 45 50 EABx 60 370 10 55 60 EABx 75 300 12 70 75 EABx 95 240 19 90 95 EABx stands for EAB EABA EABC Torque range ft lb Model Min Nominal Max EABx 15 900 3 69 9 59 11 06 EABx 26 560 3 69 17 70 19 18 EABx 32 410 5 16 22 13 23 60 EABx 45 330 6 64 29 50 33 19 EAB...

Страница 6: ...EABx 75 300 2 94 6 48 EABx 95 240 2 98 6 57 EABx stands for EAB EABA The weight is given without the battery pack Storage and use conditions Storage temperature 20 to 70 C 4 to 158 F Operating temperature 0 to 45 C 32 to 113 F Storage humidity 0 95 RH non condensing Operating humidity 0 90 RH non condensing Altitude up to 2000 m 6562 feet Usable in Pollution degree 2 environment Indoor use only Ac...

Страница 7: ...re a longer service life of the battery pack Unplug the battery pack when the tool is not used Do not leave the battery pack on the charger when the charger power supply is off How to connect the tool to CVIMONITOR Plug a battery pack to the tool Connect eDOCK to the tool and to the USB port of the computer Respect the connection order Launch CVIMONITOR from the computer desktop Click Tool in the ...

Страница 8: ...Additional icons and buttons Reverse mode once The tool will run in reverse once only To run the tool in reverse again the operator will have to press the Re verse button Reverse mode alternate The tool will run in reverse until the operator presses the Reverse button again This icon blinks when the tool memory is full New results will overwrite the oldest results How to disable the passwords On d...

Страница 9: ...uration Go to Set password then Pset password use the buttons to enter a figure from 0 to 999 save and validate Setting the password to 0 will disable all password protections The procedure is the same to set up a new Maintenance password Sound torque unit Sound The tool can emit sounds to alert the operator in case of problems or events that may happen during the tightening operation Sounds can b...

Страница 10: ... If no action is done the display returns to the main screen after 15 seconds and the changes will not be saved Pressing the trigger at that stage will cancel all modifications done Parameter Description Thread Selection of the thread direction of the screw CW when operating in forward the tool rotates clockwise CCW when operating in forward the tool rotates counter clockwise Target torque The tor...

Страница 11: ...torque 3 Downshift torque Torque value where the speed moves from Rundown speed to Downshift speed 4 Downshift speed Speed applied from Downshift torque to the motor stop Operating Instructions How to use the tool Starting the tool Fit the tool with a suitable socket Select the appropriate Pset Hold the tool by means of the handle and apply to the fastener to be tightened WARNING Risk Of Injury As...

Страница 12: ...et start torque 6 Angle start 7 Min angle 8 Max angle Examples Both torque and angle within tolerances will lead to a green LED reporting Torque within tolerances and angle below tolerances will lead to red yellow status red LED For tools running in severe applications it may happen that reports are null when the battery is low Reporting LEDs 1 Red 2 Green 3 Yellow ...

Страница 13: ...must be disabled for tightening tests or certification on tightening benches Ergostop allows a smoother tool stop to reduce the torque reaction on the operator When delivered this function is disabled Go to the main screen Press this button during 2 seconds Go to Ergostop Use the buttons to enable or disable the function save and validate How to wake up EAB tools The tool display switches off auto...

Страница 14: ...Operation EN 14 24 06 2020 Launch CVI MONITOR to collect and display the last 100 results Refer to the user manual of CVIMONITOR available at https www desouttertools com resource centre ...

Страница 15: ...udio test The tool emits a sound The green tick displayed indicates the function is working properly Tool identification with CVIMONITOR Click this icon Click Tool identification Go to the bottom of the screen and click Read tool A green tick indicates the reading is successful Maintenance Instructions Instructions for transducerized tools Do not damage the wires when pulling out the connectors Do...

Страница 16: ...s refer to the table below depending on which occurs sooner Maintenance frequency 500 000 tightenings Service alarm on tool display An alarm can be displayed when service is required This icon is displayed One of the service levels is displayed see below When no service is required none is displayed A sound is heard It is possible to set 3 service levels Level Number of tightenings Service level 1...

Страница 17: ...ble drift of the tool torque or after any change of tool element In the manual mode the standard procedure is executed Measurements and values are typed manually by the operator The equipment required is as follows Tool equipped with a torque transducer in line CVIMONITOR Delta measuring unit Click this icon Click Tool calibration The standard procedure is as follows 1 Select the Pset to execute 2...

Страница 18: ...run during around 1 minute and will stop automatically Click Stop motor align to stop the process before the end Release the trigger Declaring fixed accessories A fixed accessory mounted on a tool must be declared in this screen Click this icon Click Tool identification Select the type of accessory and fill in the parameters Click Write to tool It is mandatory to calibrate the tool equipped with t...

Страница 19: ...ection 1 Change the direction of the rotary selector 2 Verify that the rotary selector is in correct position or not damaged I205 Torque settings 1 Invalid Torque setting torque is greater than tool characteristics 2 Check Pset settings with the tool characteristics I206 Speed settings 1 Invalid speed setting speed is greater than tool characteristics 2 Check Pset settings with the tool maximum sp...

Страница 20: ... problem occurs again contact your Desoutter representative for sup port E018 Torque out of range 1 The target torque value is above the tool maximum torque 2 Check Pset settings with tool characteristics E029 The battery is empty 1 The battery back is discharged The tool cannot tighten 2 Recharge the battery pack E031 Battery error 1 Abnormal battery voltage The tool cannot tighten 2 Recharge the...

Страница 21: ...outter representative for support E227 Motor stalled 1 Motor stalled could be missing phase wrong motor tune or power electronics failure 2 Try once again 3 If the problem occurs again contact your Desoutter representative for support E228 Drive error 1 Software failure 2 Restart the system 3 If the problem occurs again contact your Desoutter representative for support ...

Страница 22: ......

Страница 23: ......

Страница 24: ...icles Off Road General Industry Desoutter offers a comprehensive range of Solutions tools service and projects to meet the specific demands of local and global customers in over 170 countries The company designs develops and delivers innovative quality industrial tool solutions including Air and Electric Screwdrivers Advanced Assembly Tools Advanced Drilling Units Air Motors and Torque Measurement...