![Desmi PVLB Series Скачать руководство пользователя страница 5](http://html.mh-extra.com/html/desmi/pvlb-series/pvlb-series_operation-and-maintenance-instructions_2487041005.webp)
______________________________________________________________________________
DESMI Pumping Technology A/S
P a g e
| 3
9400 Nørresundby – Denmark
Tel: +45 96 32 81 11 Fax: +45 98 17 54 99
E-mail:
When using the pump for other media the operator is responsible for checking that the specified
materials in the pumps are in order. In case of doubt, contact the supplier.
The noise level for the airborne noise appears from the following list. The values indicated are
measured as middle values at a distance of l m from the machine surface in free field approx. 1.5 m
above the base plate. The sound pressure levels are general directional values which cannot be
regarded as guarantee values for each individual pump, as the sound level of a pump is to a large
extent dependent on the installation method and the operating conditions. The measuring comprise
the pump including the motor.
Sound pressure level for the PVLN-pumps:
PVLN Type
dB(a)
PVLN Type
dB(a)
1050.81
40
1100.41
71
1050.61
47
2100.61
64
1050.27
70
2100.41
72
1050.22
78
2125.62
68
1050.21
80
2125.44
74
1065.61
47
2125.43
76
1065.42
53
2125.42
77
1065.41
55
2125.41
78
2065.23
81
2150.82
69
2065.22
83
2150.62
73
1065.21
84
2150.61
74
0080.61
52
2150.43
78
0080.42
56
2150.42
79
0080.41
57
2150.41
80
0080.22
80
2200.82
70
0080.21
81
2200.81
71
2080.42
58
2200.62
74
2080.41
62
2200.61
76
2080.23
40
2200.44
79
2080.22
84
2200.43
80
2080.21
84
2200.42
81
1100.61
58
2200.41
82
Environment
:
The pumps are as a standard equipped with motors with protection class IP54, which
means that the motor is protected against penetrating dust and that water without pressure does not
damage the motor. The motors are dimensioned for an ambient temperature of 40°C. Pumps installed
in explosive areas must be equipped with explosion-proof motors. The pump capacity is stamped on
the name plate.