where index "calc" is the values calculated by the user.
At the same time none of the forces or moments may exceed the indicated figure multiplied by 1.4.
3.
INSTALLATION
3.1
MOUNTING/FASTENING
The pump should be mounted and fastened on a solid base plate or wall mounted frame so distortion
is avoided.
The max. permissible loads on the flanges stated in paragraph 2.2 are to be observed.
At installations pumping hot or very cold liquids, the operator must be aware that it is
dangerous to touch the pump surface and, consequently, he must take the necessary
safety measures.
3.2
WIRING
Wiring to be carried out by authorised skilled workmen according to the rules and
regulations in force.
4.
TRANSPORT/STORAGE
The weights of the pumps in A and D combination (without motor) are stated in the following table,
and the pumps are to be lifted as shown below.
Pump size
Weight in kg
A16 / D16
Pump size
Weight in kg
A16 / D16
65-215
176 / 191
125-330
306 / 312
65-265
184 / 201
125-415
414 / 434
80-215
187 / 204
150-265
256 / 289
80-265
185 / 202
150-330
369 / 359
80-330
276 / 281
150-415
459 / 479
100-215
198 / 213
200-265
335 / 375
100-265
203 / 224
200-330
439 / 424
100-330
291 / 297
200-415
554 / 574
100-415
379 / 399
250-330
519 / 509
125-215
217 / 241
250-415
634 / 639
125-265
221 / 246
300-415
734 / 734
The pump is to be stored in a dry area.
Before shipment the pump is to be fastened securely on pallets or the like.
The pumps are to be lifted in the following way: