10.
TRANSPORTATION
AND
STORAGE
10.1
TRANSPORTATION
1. Transport the pump to the tray or the position specified on
the package.
2. Make sure that the pump is stable.
3. If any, please follow the instructions on the package.
Warning
The pump must be lifted as per the current lifting
guideline. Only qualified personnel are allowed to lift the
pump.
Warning
Do not lift the pump with the frequency converter (if
provided with a frequency converter), electric appliance parts
or motor cover. Make sure that the pump keeps balanced
when it is lifted.
Warning
The pump may be inclined when it is lifted. Before
correct placement and installation, do not dismantle the lifting
device on the pump.
Warning
All pump motors are provided with lifting-eye bolts. If such bolts cannot
withstand the weight of the whole pump, the water pump with a standard motor
shall be lifted at the pump head via steel belts or in a similar method.
10.2
STORAGE
It is suggested that ethylene glycol is filled into the pump chamber during pump storage so
as to avoid frost.
Storage
Ambient temperature (°C)
-10 / +40
Maximum humidity
Less than 80% and no condensation
occurs to the pump at 20°C
11.
TROUBLE