1.  PRODUCT DESCRIPTION 

 
These operation and maintenance instructions apply to the DESMI MODULAR H Monobloc pump 
series. The pumps are available in sizes ranging from 40 to 80 mm on the pressure flange. The 
suction flange is bigger than the pressure flange. DESMI H is a single-stage centrifugal pump with 
stainless  steel  shaft,  mechanical  shaft  seal,  and  closed  impeller.  The  pump  is  suitable  for  the 
pumping of clean and polluted liquids with temperatures between 0 and 80°C. With special shaft 
seal  and ball bearing up to 120°C. Max. number of revolutions: 3600 RPM. 
 
The pump has horizontal inlet on the centre line and vertical outlet at the top. The back of the 
impeller  is  equipped  with  relief  blades  to  reduce  the  load  on  the  bearings.  Relief  holes  in  the 
impeller ensure circulation of liquid for the shaft seal and prevent overheating of the shaft seal 
during normal operation. 
 
The pump is particularly suitable for the pumping of water in connection with washing plants, air 
conditioning, cooling systems, and sanitary systems, etc. Furthermore, in the majority of cases 
where the transport of liquid is required within industry. 
 

1.1 DELIVERY 
 

-

 

Check on delivery that the shipment is complete and undamaged. 

-

 

Defects  and  damages,  if  any,  to  be  reported  to  the  carrier  and  the  supplier 
immediately in order that a claim can be advanced. 

 

2. TECHNICAL DATA 

 
The  pumps  are  manufactured  in  various  material  combinations,  which  appear  from  the  type 
number on the nameplate. See below. 
 

2.1 EXPLANATION OF THE TYPE NUMBER 
 
All the H-pumps are provided with a nameplate. The type number indicated on the nameplate is 
built up as follows: 
 
H-XX-YYY-MR 
XX.YYY: Pump size 
M:  The material combination of the pump.  
R:  The assembly combination of the pump. 
 
M may be the following: 
A:  Standard. Casing: GG20. Impeller:AlBz.  
C:  All cast iron. 
D:  Casing: RG5, Impeller: AlBz. 
E:  Casing and shaft seal cover:  NiAlBz and bronze alloy. Impeller and sealing rings: NiAlBz. 
 
 
 
 
 

Содержание H-40-160

Страница 1: ...NANCE INSTRUCTIONS DESMI centrifugal pump MODULAR H Monobloc DESMI PUMPING TECHNOLOGY A S Tagholm l DK 9400 N rresundby Tel 45 96 32 81 11 Fax 45 98 17 54 99 Manual T1351 Language English Revision H 1...

Страница 2: ...ING RING IN PUMP CASING 7 6 2 FITTING BEARING 7 6 3 FITTING WATER DEFLECTOR 7 6 4 FITTING SHAFT SEAL 7 6 5 FITTING IMPELLER 8 6 6 FITTING BEARING COVER AND SHAFT SEAL COVER 8 6 7 SHAFT 8 6 8 FITTING C...

Страница 3: ...in the impeller ensure circulation of liquid for the shaft seal and prevent overheating of the shaft seal during normal operation The pump is particularly suitable for the pumping of water in connect...

Страница 4: ...lowering etc Pumps in material combinations A and C are primarily used for fresh water Pumps in material combination D are primarily used for seawater If the pumps are designed for special purposes th...

Страница 5: ...F F yout Fxout F yin Fxin 2 2 2 2 t M M zout M yout M xout M zin M yin M xin 2 2 2 2 2 2 2 2 2 t M calc M F calc F where indices in is suction branch out is pressure branch and calc are the values ca...

Страница 6: ...rely on pallets or the like The pump is to be lifted in the following way The lifting straps must not bear against sharp edges and corners 5 DISMANTLING 5 1 ACCESS TO IMPELLER Remove guards 28 Remove...

Страница 7: ...e the bearing If the coupling is removed after dismantling the pump fix the shaft at the thread on the opposite shaft end while the coupling is pulled off 6 ASSEMBLING 6 1 FITTING SEALING RING IN PUMP...

Страница 8: ...R AND SHAFT SEAL COVER Place the gasket between pump casing and shaft seal cover on the shaft seal cover where it can be held with a little grease Fit and fasten bearing cover and shaft seal cover Che...

Страница 9: ...the direction is correct i e in the direction of the arrow the pump may be started 10 SYSTEM BALANCING It is often difficult to calculate a manometric delivery head in advance It is however decisivel...

Страница 10: ...phases Insert orifice plate or check valve contact DESMI Contact DESMI Dismantle the pump remove the cause Check fuses cable connection and cable The pump makes noise 1 Cavitation in pump Suction lif...

Страница 11: ...RPM H 40 160 175 0 8 1 3 5 7 9 4 8 0 11 0 18 0 22 26 30 50 68 4 0 7 0 20 28 9 0 13 0 37 53 H 40 160 165 0 6 1 1 4 8 8 7 0 8 0 15 0 19 25 30 45 57 3 5 5 5 17 0 23 8 4 12 0 34 47 H 40 160 155 0 5 0 9 4...

Страница 12: ...1998 A1 2009 Pumps and pump units for liquids Common safety requirements EN12162 2001 A1 2009 Liquid pumps Safety requirements Procedure for hydrostatic testing EN 60204 1 2006 A1 2009 Safety of machi...

Страница 13: ...desmi desmi com www desmi com 15 INFORMATION RELEVANT FOR DISASSEMBLY OR DISPOSAL AT END OF LIFE No damage materials are used in DESMI pumps please refer to DESMI Green Passport can be sent on request...

Страница 14: ...casing 15 Bearing cover 75 INSEX screw 2 Pipe plug 16 Allen screw 76 Sunk key 3 Pipe plug 17 Shaft 80 Sealing washer 4 Sealing ring 18 Shaft seal cover 81 Sealing washer 5 Impeller 19 Coupling 82 Seal...

Страница 15: ...212 265 50 12 14 160 200 4x18 H 65 160 95 125 212 280 65 12 14 160 200 8x18 H 65 200 95 125 250 320 65 12 14 180 225 8x18 H 80 200 95 125 280 345 65 14 14 180 250 8x18 Type l2 g A f Dn1 K1 D2 Dn2 K2 Q...

Отзывы: