3.
INSTALLATION
3.1
MOUNTING/FASTENING
The pump should be mounted and fastened on a solid base plate or wall mounted frame so
distortion is avoided.
When installing the pump check that it is earthed to avoid an electrical potential in the pump.
The max. permissible loads on the flanges stated in paragraph 2.2 are to be observed.
At installations pumping hot or very cold liquids, the operator must be aware
that it is dangerous to touch the pump surface and, consequently, he must take
the necessary safety measures.
3.2
WIRING
Wiring to be carried out by authorised skilled workmen according to the rules and
regulations in force.
4.
TRANSPORT/STORAGE
The weights of the pumps in standard combination (without motor) are stated in the following
table, and the pumps are to be lifted as shown below.
Pump
Weight in kg
without motor & base plate
ESLH 25-180
40
The pump is to be stored in a dry area.
Before shipment the pump is to be fastened securely on pallets or the like.
The pump is to be lifted in the following way:
The lifting straps must not bear against sharp edges and corners.