LOCAL DIMMING CONTROL

 

This function is to LOCALLY DIM THE LED INTENSITY from 0 to 100% 
(Product is delivered with default setting of the Dimmer at 0) 
he right knob is doing the dimming action and it goes with a fine tuning in 
normal condition, or a fast dimming when rotating KNOB 2 while keeping 
KNOB 1 pressed in. 

 

 

 

 

 

When the DISPLAY is in STAND BY Mode, please rotate 
KNOB 2 to act on 

the LIGHT INTENSITY Dimming…Clock 

Wise  to  increase  the  level  and  Counter  Clock  Wise  to 
decrease it. Fine control: 

 

1 full TURN of the KNOB 2 = 5% Dimming Variation

 

For faster Dimming Control keep KNOB 1 pressed 
and rotate KNOB 2:  
1 full TURN of the KNOB 2 = 40% Dimming 
Variation 

 

1 full TURN of the KNOB 2 = 5% Dimming Variation

 

LOCAL CORRELATED COLOR TEMPERATURE 
CONTROL

 

This function is to LOCALLY ADJUST the CORRELATED 
COLOR TEMPERATURE from 2.750°K to 6.900°K (Product 
is delivered with default setting of the CCT at 2750°K) 
 
The rotation of KNOB 1 will determine CCT increments 
according to the following table (STEP MODE) 
 
If a continuous CCT Adjustment is required (LINEAR 
MODE) it is necessary to operate through a DMX Console: 
please see DMX parameters above 

 

 

 

 

 

 

LOCAL OR REMOTE CONTROL SETTINGS

 

The LED Fresnel has the facility to block the LOCAL DIMMING and CCT 
SETTINGS and maintain it when the POWER is turned off and than on again.  
This allows for the LIGHT to be TUNED and FOCUSED locally and its dimming 
plus CCT level can be blocked, so that for instance a system lighting a SET can be 
operated by a remote switch or simple brakers by TURNING POWER ON. 
The machine is set to Auto save OFF as default: in this condition the Fixture can 
be controlled locally until a DMX device is connected to it. Once the Console will 
be acting it will take priority over any local control.  
To turn the Auto sve ON please follow these instructions: 
- rotate KNOB 2 and select Auto save OFF 
- press KNOB 2 to highlight the status of Auto save, in this case OFF 
- rotate KNOB 2 to turn the status of Auto save to ON and press it 
- leave the settings in this condition; the light will ignore any DMX Control. In this 
mode any local dimming setting will be maintained and will be automatically 
recalled after power off, when turnig the power on again.  
 

 
 

 

 

CHANNEL SETTING (RESOLUTION & FUNCTION)

 

This function is to SET THE DIMMING RESOLUTION either at 8 bits or at 16 bits.  
Select DMX resol by rotating and pushing KNOB2, the following choices are 
available: 
- 8 bits resolution (the display will show 8 bit). The fixture utilizes 1 DMX Circuit for 
the Light Dimming, which is the BASE CIRCUIT set in the ADDRESS. 
- 16 bits: 16 bits resolution (the disply will show 16 bit and this is the default 
setting). 
The fixture utilizes 2 DMX Circuits: 
The Base Circuit set in the address is the Coarse Dimming, the second Circuit 
(Base +1) is the Fine Dimming.  
Of course the benefit of the 16 bits function the corresponding circuits on the DMX 
Lighting Board shall also beset at 16 bits.  
The DMX channels Base +2 and Base +3 are dedicated to the CCT Variation 
Control as described previously. 
 

 

 

 

 

 

Содержание SUPER LED F14

Страница 1: ...ns you can depend upon the quality of this product The SUPER LED F14 is a compact highly efficient Fresnel lens spotlight using a LED ARRAY combined with the DE SISTI Patented optical system to optimi...

Страница 2: ...AND PERFORMANCE DATA DESCRIPTION VALUE DESCRIPTION VALUE LED Power 400 W Protection Type IP22 Power Consumption 490 W 230V 50 60 Hz Max Housing temperature 70 C 490 W 120V 50 60 Hz DMX Data Link USIT...

Страница 3: ...ected to the connection point marked with the letter L or colored in red Working conditions Working Position Lighting fixture max tilting 90 from horizontal Ambient temperature ta at the place of inst...

Страница 4: ...of 0 1m 4 in around fans and air vents Shields lenses safety or dichroic glasses shall be changed if they have become visibly damaged to such an extent that their effectiveness is impaired for example...

Страница 5: ...l go in STAND BY Mode It will go ON again anytime a KNOB is activated KNOB 2 It is as a DEFAULT the DIMMING Variation Knob By rotating it clockwise the Dimming of the Light Changes from 0up to Full Li...

Страница 6: ...again This allows for the LIGHT to be TUNED and FOCUSED locally and its dimming plus CCT level can be blocked so that for instance a system lighting a SET can be operated by a remote switch or simple...

Страница 7: ...it INFORMATION PROVIDED ON THE DISPLAY 8 DIMENSIONS Dimensions Black mm Red inches Dimensions Black mm Red inches Display of Correlated Colour Temperature Display of LED Case TEMPERATURE Display of D...

Страница 8: ...D with Isopropyl alcohol 3 Clean the lenses with a soft damp cloth 4 Check the condition of the safety shield see chapter Installation Instructions before every use 5 Check Power supply cable and DMX...

Отзывы: