background image

6

Step 2. (Fig. 13) Motor to Receiver Electrical 
Connections:  Connect  the  black  wire  
from the fan to black wire marked "TO 
MOTOR L". Connect  the  white  wire  from  
the  fan to the white wire marked "TO 
MOTOR N" from the receiver.  Connect  the 
blue wire from the fan to the blue wire 
marked "For Light" from the receiver. 
Secure the wire connections with the 
plastic wire nuts provided.

Step 3. (Fig. 13) Receiver to House Supply 
Wires Electrical Connections:  Connect the 
black (hot) wire from the ceiling to the 
black wire marked "AC in L" from the 
receiver. Connect the white(neutral) wire 
from the ceiling to the white wire marked 
"AC in N" from the Receiver. Secure the 
wire connections with the plastic wire nuts 
provided.

Note: Fan must be installed at a maximum 
distance of 30 feet from the transmitting 
unit for proper signal transmission 
between the transmitting unit and the 
fan's receiving unit.  

7. FINISHING THE 

INSTALLATION

Step 1. Tuck connections neatly into 
ceiling outlet box.

Step 2. Slide  the  canopy up to ceiling 
and over the two screws on hanger 
bracket. Rotate canopy clockwise, next, 
while holding the canopy with one hand, 
slide the canopy cover over the screws 
and rotate clockwise until tight. Note: 
adjust the canopy screws as necessary 
until the canopy and canopy cover are 
snug. (Fig.14)

Warning: Make sure tab at bottom of 
hanger bracket is properly seated in 
groove of hanger ball before attaching 
canopy to bracket. Failure to properly seat 
tab in groove could cause damage to 
electrical wiring.

Figure 13

Figure 14

White (neutral)

White (neutral)

Green or bare
copper (ground)

White ("AC IN N")

White ("to motor  N")

Ground
(green)

(Connect to
ground wire on
hanger bracket
if no house
ground wire 
exists.)

Outlet box

Black (hot)

Black ("AC IN L")

Black ("to motor  L")

Receiver

Blue (for  light)

Blue (for  light)

Black (motor)

Outlet box

Hanger
bracket

Canopy

Canopy cover

Screws

Содержание 52LA2L5-AVW

Страница 1: ...NG AC 120V 60Hz UL LISTED MODEL AC 523OD MODEL 52LA2L5 AVW CEILING FAN OWNER S MANUAL Distinctive Lighting and Ceiling Fans READ AND SAVE THESE INSTRUCTIONS FOR CEILING FAN PARTS AND SERVICE CALL 1 877 902 5588 ...

Страница 2: ...reverse function on this fan press the reverse button while the fan is running 9 Avoid placing objects in the path of the blades 10 To avoid personal injury or damage to the fan and other items be cautious when working around or cleaning the fan 11 Do not use water or detergents when cleaning the fan or fan blades A dry dust cloth or lightly dampened cloth will be suitable for most cleaning 12 Aft...

Страница 3: ...ts l Wall transmitter incl 2 mounting screws m Wall plate w 2 mounting screws n 12V MN21 A23 battery o Package hardware 1 Mounting hardware screws 2 lock washers 2 star washers 2 wire nuts 3 wood screws 2 washers 2 2 Blade attachment hardware screws 16 fiber washers 16 3 Balance Kit Philips screw driver Blade screw driver 11 mm wrench Step ladder Wire cutters 2 2 TOOLS AND MATERIALS REQUIRED WARNI...

Страница 4: ...eight of the fan at least 50 lbs Do not use plastic outlet boxes Figures 1 2 and 3 are examples of different ways to mount the outlet box Note You may need a longer downrod to maintain proper blade clearance when installing on a steep sloped ceiling Fig 3 To hang your fan where there is an existing fixture but no ceiling joist you may need an installation hanger bar as shown in Figure 4 Outlet box...

Страница 5: ...en through the ball downrod Fig 7 NOTE Do not install the coupling cover if you plan to use the 4 downrod Step 7 Align the holes at the bottom of the downrod with the holes in the collar on top of the motor housing Fig 7 Carefully insert the hitch pin through the holes in the collar and downrod Be careful not to jam the pin against the wiring inside the downrod Insert the locking pin through the h...

Страница 6: ... Fig 11 Step 1 Fig 12 Insert the receiver into the mounting bracket with the flat side of the receiver facing the ceiling Figure 10 Figure 9 Figure 11 Figure 12 Receiver Hanger bracket CHANGING THE DOWNROD OPTIONAL NOTE Your fan comes with a 6 downrod attached to the hanger ball In addition you have been provided with a 4 downrod to use if desired If you choose to use the 4 downrod perform the fol...

Страница 7: ...between the transmitting unit and the fan s receiving unit 7 FINISHING THE INSTALLATION Step 1 Tuck connections neatly into ceiling outlet box Step 2 Slide the canopy up to ceiling and over the two screws on hanger bracket Rotate canopy clockwise next while holding the canopy with one hand slide the canopy cover over the screws and rotate clockwise until tight Note adjust the canopy screws as nece...

Страница 8: ...Fig 15 Figure 15 Figure 16 Screws Screws Rubber washers Blade bracket Blade 9 INSTALLING THE MOUNTING PLATE 1 Remove the 1 of 4 screws from the mounting ring and loosen the other 3 screws Do not remove 2 Place the key holes on the mounting plate over the 3 screws previously loosened from the mounting ring turn mounting plate until it locks in place at the narrow section of the key holes Secure by ...

Страница 9: ...nnectors Fig 17 2 Carefully push all wires back into the mounting plate then install the light kit onto the mounting plate with 3 screws provided Be sure to tighten all screws Fig 17 11 INSTALLING THE LIGHT BULBS GLASS SHADE 1 Install 3 x 40w candelabra bulbs not included Fig 18 2 Remove the decorative nut and metal nut from the light kit Place glass shade over the light kit stem secure with the m...

Страница 10: ... time it was turned off D The REV button is used to set the fan forward or reverse press the button forward for warm weather or reverse for cool weather Speed settings for warm or cool weather depend on factors such as the room size Ceiling height number of fans and so on NOTE To operate the reverse function on this fan press the reverse button while the fan is running Warm weather Forward A downw...

Страница 11: ...e fan with wall mounted variable speed control s 7 Make sure the upper canopy is a short distance from the ceiling It should not touch the ceiling 1 Do not connect the fan with wall mounted variable speed control s 2 Make sure the dip switches are set correctly 1 Check that all blade and blade arm screws are secure 2 Most fan wobbling problems are caused when blade levels are unequal Check this le...