background image

www.fmiproducts.com

125079-01B

22

MAIN

IN

OUT

PILOT

ADJ

PILOT

OPerAtiOn

FOR YOUR SAFETY  

READ BEFORE LIGHTING

 WARNING: If you do not fol-

low  these  instructions  exactly, 

a  fire  or  explosion  may  result 

causing property damage, per

-

sonal injury or loss of life.

A.  This appliance is equipped with an igni

-

tion device which automatically lights 
the pilot. Do not light pilot by hand.

B.  BEFORE  LIGHTING  smell  all  around 

the appliance area for gas. Be sure to 
smell next to the floor because some 
gas is heavier than air and will settle 
on the floor.

 

WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.
• Do not touch any electric switch; do 

not use any phone in your building.

• Immediately  call  your  gas  supplier 

from a neighbor's phone. Follow the 
gas supplier's instructions.

C.  Do  not  use  this  appliance  if  any  part 

has been under water. Immediately call 
a qualified service technician to inspect 
the appliance and to replace any part of 
the control system and any gas control 
which has been under water.

LIGHTING 

INSTRUCTIONS

NOTICE: During initial operation 

of  new  fireplace,  burning  logs 

will  give  off  a  paper-burning 

smell.  Orange  flame  will  also 

be  present.  Open  damper  or 

window to vent smell. This will 

only last a few hours.

Figure 31 - Turning Equipment Shutoff Valve to the OFF Position

Equipment 
Shutoff Valve

1.  STOP!  Read  the  safety  information  in 

column 1.

2.  Turn off all electric power to fireplace.
3.  Turn  safety  shutoff  switch  to  the  OFF 

position.

4.  Remove center brick/control cover.
5.  Turn  equipment  shutoff  valve  clockwise 

  to  the  OFF  position  (see  Figure 

31). Do not force.

6.  Wait five (5) minutes to clear out any gas. 

Then  smell  for  gas,  including  near  the 
floor. If you smell gas, STOP! Follow “B” 
in the safety information page 22. If you 
don't smell gas, go to the next step.

7.  Turn  equipment  shutoff  valve  counter

-

clockwise 

 to the ON position. Do 

not force.

8.  Replace center brick/control cover.
9.  Turn on all electric power to appliance.
10. Turn  safety  shutoff  switch  to  the  ON 

position.

11. Visually locate pilot. Ignitor should begin 

to  spark  and  main  burner  should  ignite 
once flame appears at pilot.
• If lighting appliance for the first time each 

season,  it  may  take  several  attempts 
before  supply  gas  can  reach  pilot  and 
main burners.

• If appliance will not stay lit after several 

attempts,  follow  instructions  under 

To 

Turn Off Gas To Appliance

 and call your 

service technician or gas supplier.

TO TURN OFF GAS 

TO AppLIANCE

1.  Turn off safety shutoff switch.
2.  Turn off all electric power to appliance if 

service is to be performed.

3.  Remove center brick/control cover.
4.  Turn  equipment  shutoff  valve  clockwise 

 to OFF. Do not force.

5.  Replace center brick/control cover.

Incoming 

Gas Line

Содержание DVF-36NH-D

Страница 1: ... your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a quali fied installer service agency or the gas supplier INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference Direct vent FIREPLACE OWNER S O...

Страница 2: ... DANGER Carbonmonoxide poisoning may lead to death This vented gas fireplace is a sealed combus tion gas fireplace designed for residential ap plications This fireplace must be installed with FMI PRODUCTS LLC vent pipe components and terminations This fireplace complies with the National Safety Standards and is listed and tested by PFS Corporation to ANSI Z21 50 CSA 2 22 standard as vented gas fir...

Страница 3: ...vicingmustbereplacedprior to operating fireplace WARNING Donotuseablow er insert heat exchanger insert orotheraccessorynotapproved for use with this fireplace WARNING This appliance is only for use with the type of gasindicatedontheratingplate Thisapplianceisnotconvertible for use with other gases unless a certified kit is used Safety Continued WARNING Donotallowfans toblowdirectlyintothefireplace...

Страница 4: ...t from carpeting bedding material etc Turn off the gas valve and pilot light before cleaning fireplace Safety Continued 6 Have venting system inspected annually by a qualified service person If needed have venting system cleaned or repaired See Cleaning and Maintenance page 24 7 Do not use any solid fuels wood coal paper cardboard etc in this fireplace Use only the gas type indicated on fire place...

Страница 5: ...installation is very important to allow for proper operation You must follow the venting instructions very carefully for either vertical or horizontal applications This fireplace may be installed in any room of your house provided all local codes and these installation instructions are followed Each time you turn on your fireplace you may notice some amount of condensation on the inside of the fir...

Страница 6: ... on carpeting vinyl tile or any combustible mate rial other than wood it must be installed on a metal or wood panel extending the full width and depth of the fireplace see Figure 3 If standoff spacers are attached to your fireplace these spacers can be placed directly against wall or framing material See framing details page 7 When locating termination cap it is impor tant to observe the minimum c...

Страница 7: ...al heating system you may run system s circulat ingblowerwhileusingfireplace This will help circulate the heat throughout the house Framing and finishing Figure 4 shows typical framing of this fireplace Figure 5 shows framing for corner installation All minimum clearances must be met If you are using a separate combustible man tel piece refer to Figure 6 for proper instal lation height You can ins...

Страница 8: ...in US if greater than 50 000 36 91 cm in Canada if greater than 100 000 K clearance to a mechanical air supply inlet In Canada 6 ft 1 83m minimum In US 3 ft 91 cm above if within 10 ft 3 m horizontally L clearance above paved side walk or a paved driveway located on public property 84 213 3 cm minimum M clearance under veranda porch deck 12 30 5 cm minimum N clearance above a roof shall extend a m...

Страница 9: ...ctly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than 1 2 in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon inspection the inspecto...

Страница 10: ...ipe components and terminations The venting system must terminate on the outside of the structure and can not be at tached to a chimney or flue system serving a separate solid fuel or gas burning appliance A direct vent appliance must have its own venting system DO NOT common vent this appliance These models are approved to be vented either horizontally through an outside wall or vertically throug...

Страница 11: ...dentations These lugs will slide straight into match ing slots on male ends of adjacent pipes Push pipe sections together and twist one section clockwise approximately one quarter turn until sections are fully locked see Figure 8 Note Horizontal runs of vent must be sup ported every three feet Use wall straps for this purpose 3 Assemble desired combination of pipe and elbows to fireplace flue coll...

Страница 12: ... Siding standoff must sit flush against exterior fascia material 6 Connecting Vent Cap with Horizontal Vent Pipe Slide wall firestop over vent pipe before connecting horizontal run to vent cap see Figure 12 Figure 10 Installing Horizontal Vent Cap Noncombustible Exterior Wood Screw Vent Cap Figure 11 Installing Siding Standoff Combustible Exterior Wall Cut Siding Away to Fit Standoff Wood Screw Sc...

Страница 13: ...ury property damage or loss of life GROUND FLOOR INSTALLATION Recommended Applications Through the wall using round or square termination NOT FOR CORNER INSTALLATION Figure 14 Horizontal Termination Using One 90 Elbow Vertical Termination Installation Note Vertical restrictor must be installed in all vertical installations 1 Determine route your vertical venting will take If ceiling joists roof ra...

Страница 14: ...re must be a 1 clearance from vent pipe to combustible materials Frame opening as shown in Figure 9 page 11 4 Connect a section of pipe and extend up through hole Note If an offset is needed to avoid obstructions you must support vent pipe every 3 feet Use wall straps for this pur pose see Figure 15 Whenever possible use 45 elbows instead of 90 elbows The 45 elbow offers less restriction to the fl...

Страница 15: ...ble Wall Pipe Galvanized P58 48 48 Section Double Wall Pipe Galvanized PA58 712 Adjustable 7 12 Section Double Wall Pipe Galvanized E58 45 45 Elbow Galvanized E58 90 90 Elbow Galvanized HTS 58 Horizontal Square Termination Galvanized HHT 58 High Wind Round Termination Galvanized VT 58 Vertical Round Termination Galvanized SC 58 Storm Collar Galvanized WF 58 Wall Firestop Galvanized RF 58 6 Roof Fl...

Страница 16: ...nt shutoff valve with 1 8 NPT tap is an acceptable alternative to test gauge connection Purchase the equipment shutoff valve from your retailer For propane LP connection only the installer must supply an external regulator The exter nal regulator will reduce incoming gas pres sure You must reduce incoming gas pressure to between 11 and 14 of w c pressure If you do not reduce incoming gas pressure ...

Страница 17: ... in Figure 19 Locate sediment trap drip leg where it is within reach for cleaning Install in piping sys tem between fuel supply and fireplace Locate sediment trap drip leg where trapped matter is not likely to freeze A sediment trap traps moisture and contaminants This keeps them from going into fireplace gas controls If sedi ment trap drip leg is not installed or is installed wrong fireplace may ...

Страница 18: ...fluid to all joints Bubbles forming show a leak Correct all leaks at once 5 Reconnect fireplace and equipment shutoff valve to gas supply Check recon nected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1 Close equipment shutoff valve see Fig ure 21 2 Pressurize supply piping system by either opening propane LP supply tank valve for propane LP gas fireplace or opening ma...

Страница 19: ... removing broken glass Do not remove if glass is hot Keep children and pets away from glass WARNING If fireplace has been running turn off fireplace Let cool before removing glass doors Figure 24 Removing Replacing Door Removing Glass Door If replacement of glass is necessary the entire frame assembly must be replaced Gloves must be worn when removing replacing glass door If glass is broken tape r...

Страница 20: ...sary to use all of the glowing ember material provided 4 Place lava rock around base of burner Make sure burner ports are not covered see Figure 26 5 Place ember flakes around front and sides of burner and on burner ports see Figure 27 This will create the glowing ember ap pearance as the flame touches the ember flakes Do not block burner ports or pilot ports by overlapping ember flakes in one are...

Страница 21: ...as line and control valve see Figure 29 page 21 2 After connecting gas line to control valve always test for leaks Removing Logset Burner Module WARNING Never use an open flame to check for a leak Apply noncorrosive leak de tection fluid to joints Bubbles forming show a leak Correct leaks at once CAUTION The gas supply shall be shut off prior to discon necting the electrical power if any before pr...

Страница 22: ...ing Equipment Shutoff Valve to the OFF Position Equipment Shutoff Valve 1 STOP Read the safety information in column 1 2 Turn off all electric power to fireplace 3 Turn safety shutoff switch to the OFF position 4 Remove center brick control cover 5 Turn equipment shutoff valve clockwise to the OFF position see Figure 31 Do not force 6 Wait five 5 minutes to clear out any gas Then smell for gas inc...

Страница 23: ...Pilot Off On Switch Remote Off Switch ADJ S Pilot Connection I Pilot Connection AF 4000 MOD Module Rt Side Figure 32 Gas Module Right Side 1 There is a switch located on the right side of the module that reads REMOTE OFF Figure 33 2 When the remote off switch is in the OFF position the burner will operate from the rocker switch or wall switch connected to the two BROWN wires on the module 3 When t...

Страница 24: ...sembly The pilot assembly is factory preset for the proper flame Alterations may have occurred during shipping and handling The pilot is located on right hand side of burner The flame must envelope 1 4 of top of the ignitor sensor and grounding stem If your pilot assembly does not meet these requirements Turn the adjustment screw marked PILOT clockwise to decrease or counterclockwise to increase t...

Страница 25: ...place see Replacement Parts page 30 for detail on ordering No substitutions may be made See Removing Replacing Glass Door page 19 for instructions for re placing glass doors Cleaning and Maintenance Continued WARNING Do not operate fireplace with glass door un latched removed cracked or broken Pilot and burners Remove material before cleaning burners and replace when cleaning is complete Burner an...

Страница 26: ...l valve is not opening 7 No power to unit or ignition module REMEDY 1 Checktoseeifyouhavegas supply and that equipment shutoff valve is opened 2 Repeat lighting procedure several times to purge all air out of lines If after re peated attempts appliance does not light call for quali fied service and repair 3 Remove debris and dirt inspect and clean any other possible obstructions 4 Contact your gas...

Страница 27: ...lights Check the two plastic connectors that plug in the face of the gas control valve Confirm the gas control valve is properly grounded to the module 1 Check electrical connec tions 1 Clean and adjust pilot flame for maximum flame im pingement on thermopile 2 Have vent system inspect ed including termination cap Remove any restriction or obstruction 1 This is normal with most fireplaces If noise...

Страница 28: ...s blocked 3 Improper venting or exces sive blockage 4 Excessive amounts of em bers and pan material OBSERVED PROBLEM Gas odor even when gas control valve is off Gas odor during combustion Glass soots Dark residue on logs or inside of fireplace REMEDY 1 Locate and correct all leaks see Checking Gas Con nections page 18 2 Replace control valve 1 Take apart gas tubing and remove foreign matter 2 Loca...

Страница 29: ...H d DVF 36PSR d DVF 36PHR d Rating 47 000 28 000 Btu hr Gas Type Propane LP Gas Only Ignition Electronic Manifold Pressure 10 w c Minimum Inlet Supply Pressure 11 w c Maximum Inlet Supply Pressure 13 w c Front Orifice 53 Rear Orifice 53 DVF 42PS d DVF 42PH D DVF 42PSR d DVF 42PHR D Rating 53 000 28 000 Btu hr Gas Type Propane LP Gas Only Ignition Electronic Manifold Pressure 10 0 w c Minimum Inlet...

Страница 30: ...36nh d dvf 36ph d dvf 42ns d dvf 42ps d dvf 42nh d dvf 42ph d dvf 36nsR d dvf 36psR d dvf 36nhR d dvf 36phR d dvf 42nsR d dvf 42psR d dvf 42nhR d and dvf 42phR d 1 2 3 8 32 32 33 36 32 42 8 9 10 11 17 22 25 26 27 7 4 5 12 16 18 19 20 29 31 30 23 24 28 21 13 14 15 6 34 35 36 ...

Страница 31: ...23210 01 Grate 36 1 123210 02 Grate 42 1 8 122652 01 Door Latch 2 9 Firebox Leg 4 10 Firebox Bottom 1 11 121431 01 Gasket 36 1 111913 02 Gasket 42 1 12 122919 01 Draft Diverter 1 13 Air Exchange 1 14 5 Gasket 1 15 5 Inner Connector 1 16 A E Insulation 1 17 Firebox Surround 1 18 Firebox Top 1 19 Relief Assembly 2 20 Relief Bracket 4 21 Top Plenum 1 22 Rear Plenum 1 23 5 Gasket 1 24 Connector 8 x 3 ...

Страница 32: ...11 12 13 14 15 16 18 19 17 20 13 13 21 22 23 25 26 27 28 29 29 Parts Models dvf 36ns d dvf 36ps d dvf 36nh d dvf 36ph d dvf 42ns d dvf 42ps d dvf 42nh d dvf 42ph d dvf 36nsR d dvf 36psR d dvf 36nhR d dvf 36phR d dvf 42nsR d dvf 42psR d dvf 42nhR d and dvf 42phR d ...

Страница 33: ...Dia x 24 1 16 Pilot Bracket 1 17 125063 01 Gas Valve NG 1 125063 02 Gas Valve LP 1 18 111800 01 Screw 10 24 x 0 375 Self Thread 2 19 125064 01 Control Module 1 20 125067 01 Power Module 1 21 14396 Connector 3 8 Tube x 3 8 MPT 1 22 116786 01 Brass Fitting 1 2 Flare x 3 8 MPT 1 23 125061 01 Valve Module Bracket 1 24 Log Assembly 36 1 Log Assembly 42 1 25 125062 01 Valve Bracket 1 26 125068 01 Batter...

Страница 34: ...www fmiproducts com 125079 01B 34 Parts Refractory parts 1 2 4 5 6 3 Herringbone Brick Shown ...

Страница 35: ...3 Right Front Refractory 36 Ivory Tan 1 PARTS This list contains replaceable parts used in your fireplace When ordering parts follow the instructions listed under Replacement Parts on page 29 of this manual D V F 4 2 N P H R D D V F 3 6 N P H R D D V F 4 2 N P S R D D V F 3 6 N P S R D KEY NO PART NO DESCRIPTION QTY 1 125124 02 Rear Refractory Herringbone 42 Warm Red 1 125088 02 Rear Refractory He...

Страница 36: ...sually we will ask you to return the part to the factory Service Hints When Gas Pressure Is Too Low pilot will not stay lit burners will have delayed ignition fireplace will not produce specified heat propane LP gas supply might be low pro pane LP units only You may feel your gas pressure is too low If so contact your local gas supplier Accessories Purchase these accessories from your local dealer...

Страница 37: ..._______________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________...

Страница 38: ..._______________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________...

Страница 39: ..._______________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________...

Страница 40: ...is product and or FMI PRODUCTS LLC who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty Travel handling transportation diagnostic material labor and incidental costs associated with warranty repairs unless expressly covered by this warranty are not reimbursable under this warranty and are the responsibility of the owner Excluded ...

Отзывы: