Viper Ion Gun

Installation, Operation and Maintenance

Description

The Desco Viper Ion Gun is a point-of-use ionizer 

used for neutralizing electrostatic charges to eliminate 

attraction, visual imperfections and contamination 

issues by dislodging charged dust and debris.  It uses 

compressed clean dry air (CDA), or a special nozzle 

(

19596

) may be purchased separately for use with 

nitrogen.  Fast discharge times with ±15 volt offset 

voltage meet the required limits of ANSI/ESD S20.20 

and ESD TR53.  A high frequency piezo AC power 

supply is located Inside of hand piece to maintain 

consistent ionization performance with longer hose 

lengths (standard 6' hose included) and eliminate the 

need for a remote console. The light weight of the Viper 

Ion Gun (less than ½ pound; 200 grams) allows for 

comfortable extended use by operators.  The Viper Ion 

Gun is designed with slotted tips to meet the OSHA 

requirement for pressure relief.  A green LED on the 

back of the hand piece illuminates when the trigger is 

depressed to indicate that the gun is outputting ionized 

air. A red LED indicates abnormal output.  Normal 

power consumption is approximately 2.5 Watts.
The Viper Ion Gun and its accessories are available in 

the following item numbers:

Item

Description

19595

Viper Ion Gun

19596

Nitrogen Nozzle Tip

19597

Emitter Replacement Kit

19598

Clean Dry Air Nozzle Tip

July 2018

Figure 1.  Desco 

19595

 Viper Ion Gun

“There is sometimes a need to provide static control 

in a small defined area or location. This may be done 

to provide static control within production equipment, 

in mini-environments, or to facilitate particle removal 

from part of a product. Ionizers used for this purpose 

may be blow-off guns or nozzles that work with a 

supply of compressed air or nitrogen. They may use 

either nuclear, soft x-ray or any of the previously 

described types of corona ionization technology. It will 

be important to choose a method of ionization and 

cleanliness of the gas supply that is appropriate to the 

work area.”  (ESD handbook ESD TR20.20 section 

5.3.6.5.2.4 Point-Of-Use Ionization)
“Necessary non-conductors in the environment cannot 

lose their electrostatic charge by attachment to ground. 

Ionization systems provide neutralization of charges on 

these necessary non-conductive items (circuit board 

materials and some device packages are examples 

of necessary non-conductors). Assessment of the 

ESD hazard created by electrostatic charges on the 

necessary nonconductors in the work place is required 

to ensure that appropriate actions are implemented, 

commensurate with risk to ESDS [ESD sensitive] items”. 

(ANSI/ESD S20.20 Foreword)

Packaging

1  Viper Ion Gun

1  Power Adapter, 24VDC, with interchangeable plugs 

 (North America, UK/Asia, Europe)

1  Air Tube, 6' Length

1  Certificate of Calibration

  TECHNICAL BULLETIN TB-3065 

Made in the

United States of America

Содержание Viper Ion Gun 19595

Страница 1: ...item numbers Item Description 19595 Viper Ion Gun 19596 Nitrogen Nozzle Tip 19597 Emitter Replacement Kit 19598 Clean Dry Air Nozzle Tip July 2018 Figure 1 Desco 19595 Viper Ion Gun There is sometimes a need to provide static control in a small defined area or location This may be done to provide static control within production equipment in mini environments or to facilitate particle removal from...

Страница 2: ...er is depressed Use the Desco 19596 Nitrogen Nozzle Tip when using nitrogen as the air supply B Hanging Hook Use to hang the hand piece when not in use The hook may be rotated 90 degrees C Power LED Illuminates green when the trigger is depressed and ionized air blows out the nozzle D Alarm LED The red LED will illuminate during the following conditions the high frequency transformer breaks down a...

Страница 3: ...leaning the Emitter Point To maintain optimum neutralization efficiency and operation cleaning should be performed on a regular basis Use the Desco 60506 Emitter Point Cleaners or a swab dampened with isopropyl alcohol to clean the ion gun s emitter point 1 Disconnect the ion gun from its power supply and air supply 2 Remove the nozzle 3 Gently clean the emitter point using a swab dampened with Is...

Страница 4: ... Output Voltage 24 VDC Operating Temperature 32ºF to 104ºF 0 to 40ºC Dimensions 6 5 x 5 4 x 1 0 165 mm x 136 mm x 25 mm Weight 0 4 lbs 0 2 kg Balance 15 V Ozone 0 04 ppm Supply Pressure 7 psi to 87 psi Minimum Airflow 13 CFM Gas Input Clean Dry Air CDA or Nitrogen Gas Connection 6 mm port Enclosure Gun PBT polymer Nozzle PPS polymer Limited Warranty Warranty Exclusions Limit of Liability and RMA R...