1.  Safety Precautions: 

Read this instruction manual before  installation, wiring, operation, or maintenance  of  the product in order to achieve 
maximum performance. Improper use of this product may cause an accident resulting in injury or death, or may lead to a 
malfunction of this product. Our company will not be held liable for any usage outside this product Specifications or any 
accident caused by noncompliance with the Safety Precautions. 

 

Danger 

Failure to follow instructions may lead to death or serious injury. 

Warning 

Failure to follow instructions may lead to injury. 

Caution 

Failure to follow instructions may lead to product damage (product malfunctions, etc.). 

 

2.  Precautions for CE Marking: 

This product complies with the following EU Directives and EN standards: 

  EMC Directives: EN61000-6-2 / EN61000-6-4 

  Low-voltage Directive: EN61010-1 

  Overvoltage Category (Installation Category): I 

  Pollution Degree: 2 

  When selecting a power supply for use with this product, always use a power supply that has been certified 

by an  EU Notified Body (as a Limited  Power Source as defined in  IEC/EN60950-1 or IEC/EN61010-1)  or 
optional AC adapter. 

  Use only the power supply and signal cable included with the product to connect this product to the power 

supply. 

  Install  this product  in accordance with the installation and wiring instructions described in this  instruction 

manual. 

 

3.  Operation: 

This IONIZER consists of the following parts: The 966-II, optional nozzles, an electrode, and a high-voltage transformer. 
The ionizer displays a warning when there are abnormal conditions. It applies high-frequency-high-voltage from the high-
voltage transformer to the discharge needle inside, giving off alternating current corona discharges toward the optional 
nozzle, and produces positive and negative air ions. It transfers the air ions through the air. The ionized air neutralizes the 
static of charged objects located nearby, and removes dust that is on charged objects. One benefit of this ionizer is that it 
can transfer ionized air by using the optional air tube, in addition to air blowing directly through the air nozzle. The nozzle 
can fit the main unit. 

Appearance: 

 

 

Содержание SCS 966-II

Страница 1: ...losion proof Type Do not use this unit at a location or an atmosphere in which combustible gas or solvent is handled or else ignition or explosion may occur A high voltage is applied to the discharge needle Do not allow any conductive material including your finger any part of your body wire or any tool to get close to the needle or an electrical shock accident or a malfunction of the Unit may occ...

Страница 2: ...for use with this product always use a power supply that has been certified by an EU Notified Body as a Limited Power Source as defined in IEC EN60950 1 or IEC EN61010 1 or optional AC adapter Use only the power supply and signal cable included with the product to connect this product to the power supply Install this product in accordance with the installation and wiring instructions described in ...

Страница 3: ...stop signal HV OFF input Discharge OFF Short circuited to 0V Discharge ON Open Residual voltage 0 5V or less Ozone 0 05 ppm or less Measured Distance 300mm Ion balance 15 V or less Material Enclosure ABS Cover Stainless Discharge needle Tungsten Accessories Instruction manual Power supply and signal cable Caution label English 2 1 The applicable pressure range depends on the nozzle to be used Chec...

Страница 4: ...affected by exposure to ozone Installation Install it at a designated place by using fixing holes 3 φ3 4 The 966 II does not work well in a vertical position Please always mount it horizontal or pointing down Tightening torque on housing to the main body should be 20 N cm or less Wiring Attach wire to power supply and signal cable as follows Color Signal Name I O Description Red DC 24V Power suppl...

Страница 5: ...o the air supply Air compressor Supply cleaned air not containing water or oil to the Ionizer 6 Operation Caution Always use air when supplying power to the ionizer Otherwise the ozone concentrations inside the Ionizer will increase due to electric discharge which may cause detrimental effect on the main body and its surroundings 1 Install the equipment at a designated place and perform power supp...

Страница 6: ...ent is recommended after 20 000 hours If regular maintenance is not performed the life span of the 966 II will decrease The maintenance is very important Position the unit at a place where it is free from water and oil etc It gets wet dry it with a clean cloth Attachment of contamination to the tip of the discharge needle will deteriorate the static and elimination effect If deterioration of the s...

Страница 7: ... Check the housing of the discharge needle to confirm that it is correctly installed and securely locked Short circuited Check that the discharge needle is free from conductive materials Internal circuit is broken Turn off the power and then turn the power back on Cleaning Check indicator C C Lights up Dirt on discharge needle C C indicator remains lit even after the discharge needle has been clea...

Страница 8: ...plied After turning the Ionizer OFF wait 1 second or more before turning it ON again Do not use power supply and signal cable provided with the products for a moving section Otherwise they may break down Avoid scratching the cords of the sensor switch lead wires etc Letting the cords be subject to scratching excessive bending pulling rolling up or being placed under heavy objects or squeezed betwe...