Resistance Pro Meter Kit
Installation, Operation and Maintenance
Figure 1. SCS-73627 Resistance Pro Meter Kit
Description
The SCS-73627 Resistance Pro Meter Kit is
an instrument designed to measure resistance
point-to-point (Rtt) or surface to ground (Rtg).
Its test functions include:
l
Resistance measurement accuracy of
±
10%
(
±
20% accuracy for 1 x 10
12
ohms and greater)
l
Resistance range of <1 x 10
3
ohms to >1 x 10
12
ohms
l
Under load voltages of 10 and 100 volts
±
5%
l
Electrification period of approximately 15 seconds
The Resistance Pro Meter also measures ambient
temperature and relative humidity. Up to 100
measurements may be stored and recalled from the
meter's internal memory. This includes the resistance
value, temperature, relative humidity and test voltage
at the time of the measurement.
SCS
- 926 JR Industrial Drive, Sanford, NC 27332
East: (919) 718-0000 | West: (909) 627-9634
•
Website:
StaticControl.com
TB-9092
Page 1 of 8 December 2019
©
2019 DESCO INDUSTRIES INC
Employee Owned
The Surface Resistance Meter is referenced and
designed to be used to make measurements in
accordance with the test procedures in:
l
Compliance Verification-ESD TR53-Resistance
Measurements
l
Worksurfaces-ANSI/ESD S4.1 Worksurfaces
l
Floors-ANSI/ESD S7.1-Resistive-
Characterization of Materials Floor Materials
l
Foot Grounders-ESD SP9.2-Foot Grounders
Resistive Characterization
l
Garments-ANSI/ESD STM2.1 Garments
Seating-ANSI/ESD STM12.1-Seating-Resistive
Measurement
l
Floor/Footwear-ANSI/ESD STM97.1-Floor
Materials and Footwear- Resistance
Measurement in Combination with a Person
“
A Compliance Verification Plan shall be established
to ensure the Organization
’
s fulfillment of the
technical requirements of the ESD Control Program
Plan. Process monitoring (measurements) shall be
conducted in accordance with a Compliance
Verification Plan that identifies the technical
requirements to be verified, the measurement limits
and the frequency at which those verifications shall
occur. The Compliance Verification Plan shall
document the test methods and equipment used for
process monitoring and measurements. If the test
methods used by the Organization differ from any of
the standards referenced in this document, then
there must be a tailoring statement that is
documented as part of the ESD Control Program
Plan. Compliance verification records shall be
established and maintained to provide evidence of
conformity to the technical requirements. The test
equipment selected shall be capable of making the
measurements defined in the Compliance
Verification Plan.
”
(ANSI/ESD S20.20 section 7.3)
SCS
USER GUIDE TB-9092
Made in the
United States of America