background image

TB-3035 Page 2 of 3      

 

 

 

 

 

 

 

 

 

                  Revision May 2009

 

 

 

 

 

 

 

 

 

 

 

                                               © 2009 DESCO INDUSTRIES INC.

 

 

 

 

 

 

 

 

 

 

 

 

 

                       Employee Owned

DESCO WEST - 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178 • Fax (909) 627-7449 

DESCO EAST - One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Fax (781) 575-0172 • Website: 

Desco.com

Testing High Circuit

 – If the tester’s high range is 

35Meg. Set the knob on model 

19259

 to “35M PASS”, 

touch the TEST contact on the tester and you should 
get a green LED for the left and right feet. Set the 

knob on model 

19259

 to “35M HIGH”, touch the TEST 

contact on the tester and you should get a yellow LED 

for both the left and right feet. If the limit is set to 1Gig 

on the tester, test at 1Gig on model 

19259

, same for 

10Meg and 100Meg. Disregard the test result for the 
wrist strap, if the wrist strap circuit is on.
 

 
 
 

Testing Wrist Strap Circuit, refer to figure 2

To complete the wrist strap test, you will need to test 
the low and high limits. Refer to the dipswitch setting 
on the left side of the testers for wrist strap test ranges. 
Manufacturer’s suggested default test range is 750K 
low and 10Meg high for the US and 750K to 35Meg for 
Europe.

Do not power down the tester. Using the 2 banana 

leads included with model 

19259

. Attach 1 of the 

banana leads to the right side banana jack on model 

19259

 and connect the other end to the ground 

symbol jack on the tester. Connect the last banana jack 

to the left banana jack of model 

19259

 and the other 

end to the “SINGLE – WIRE” banana jack. Note be sure 

FOOTPLATE lead is removed.

Testing Low Circuit

 - If the tester’s low range is set to 

750K. Set the knob on model 

19259

 to the “750K LOW” 

position. Touch the TEST contact down on the tester 

and you should get a red LED for the Wrist strap. 

Disregard the test result for the footwear. Set the knob 

on model 

19259

 to “750K Pass”, touch the TEST 

contact on the tester and you should get a green LED 
for the wrist strap.

Testing High Circuit – 

If the tester’s high range is 

10Meg. Set the knob on model 

19259

 to “10M PASS,” 

touch the TEST contact on the tester and you should 

get a green LED for the wrist strap. Set the knob on 

model 

19259

 to “10M HIGH”, touch the TEST contact 

on the tester and you should get a yellow LED for the 
wrist strap. If the limit is set to 35Meg on the tester, test 
at 35Meg on model 

19259

. Disregard the test result for 

the footwear.

SPECIFICATIONS AND DIMENSIONS

 

Charge Detection

When the operator is connected to the remote and 

accumulates a voltage greater than ± 1.25 volts, the 

CHARGE LED (red) will display in its respective OP

-

ERATOR section (for charge detection data out, see 

the Data Output section on Page 8).  To disable charge 

detection on the display, shunt jumper JP6 inside the 

unit (See Page 7).  If a charge is detected while using 

this configuration, the display will remain in its previous 

state until the charge is no longer detected.

Testers limit comparator will calibrate:

19276

 - Combo X3 Tester, Data Output, w/ Dual Plate 

19277

 - Combo X3 Tester, Data Output, Programmable,  

 

w/ Stand 

CALIBRATION

There are no user adjustments on model 

19259

. Each 

value is a fixed resistor load, any model 

19259

 that falls 

out of specification will need to be sent to factory for 

repair. Using a DVM (digital voltmeter), set the meter 

to read ohms. The limit that the knob is set on can be 

measured using the DVM connected between Banana 

1 to Banana 2 and connected between Conductor 1 

and Conductor 2. Refer to figure 3.

TB-3045

 Page 2 of 3

© 2010 DESCO INDUSTRIES INC.

Employee Owned

Footwear Low Fail

Footwear Low and 

High Pass

Footwear High Fail

Wrist Strap Low Fail

Wrist Strap Low and 

High Pass

Wrist Strap High Fail

Figure 3a. Footwear status LEDs

Figure 4a. Wrist Strap status LEDs

Figure 4. Wrist Strap Test Setup

Weight: 

   0.197 Ib

Dimensions:  3.76 x 2.41 x 1.52 in 

                      9.55 x 6.12 x 4.52 cm

3.76”

9.55cm

1.52”

3.86cm

0.93”

2.36cm

2.41”

6.12cm

Figure 5. Limit Comparator specifications and 

dimensions

Отзывы: