![Desco Combo Tester X3 Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/desco/combo-tester-x3/combo-tester-x3_installation-operation-and-maintenance-manual_2486605002.webp)
TB-3066
Page 2 of 8
© 2017 DESCO INDUSTRIES, INC.
Employee Owned
DESCO WEST
- 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178
DESCO EAST
- One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Website:
Desco.com
“Compliance verification should be performed prior to
each use (daily, shift change, etc.). The accumulation
of insulative materials may increase the foot grounder
system resistance. If foot grounders are worn outside
the ESD protected area testing for functionality
before reentry to the ESD protected area should be
considered.” (ESD SP9.2 APPENDIX B - Foot Grounder
Usage Guidance)
“Compliance verification records shall be established
and maintained to provide evidence of conformity to the
technical requirements.” (ANSI/ESD S20.20 section 7.3)
Packaging
19278 COMBO TESTER X3
1 Combo Tester X3
1 Dual Foot Plate
1 Power Adapter, 12VDC, with interchangeable plugs
(North America, UK/Asia, Europe)
1 Foot Plate Cord, 6'
1 Ground Cord
1 Certificate of Calibration
19255 STAND, FOR COMBO TESTER X3
1 Pedestal
1 Baseplate
2 Socket Head Screws, 1/4-20 x 3/4"
2 Pan Head Screws, 10-32 x 5/8"
2 Nuts, 10-32
4 Pan Head Screws, #4 x 3/4"
Features and Components
Figure 2. Dual Combination Tester features and
components
B
D
H I
1 2 3
A
C
G
F
E
J K
A. Test Limit DIP Switch:
Use this DIP switch to
configure the resistance limits of the tester. See the
section titled “Tester Configuration” for more information.
B. Footwear Status LEDs
: Displays the footwear test
results.
C. 12VDC Power Jack:
Connect the included power
adapter here to power the Combo Tester X3.
D. Steady-State Test Switch:
Place and hold your
finger here to begin the test.
E. Single-Wire Wrist Strap Jack:
Insert your
single-wire wrist cord here to test your wrist strap.
F. Dual-Wire Wrist Strap Jack:
Insert your dual-wire
wrist cord here to test your wrist strap.
G. Wrist Strap Status LEDs:
Displays the wrist strap
test results.
H. Relay Terminal:
Can be integrated with electronic
door locks, lights, buzzers, etc. It is capable of switching
up to 1A @ 30VDC or .5A @ 125VAC.
Terminals 1 & 2 = Normally Closed
Terminals 2 & 3 = Normally Open
NOTE: All tests must pass in order for the relay to
activate.
I. Ground Jack:
Insert the banana plug end of the
included ground cord to this jack. Connect the ring
terminal end of the cord to equipment ground. This
connection will remove any static charge from the user
before the test.
NOTE: Failure to correctly ground the
Combo Tester X3 may result in damage not covered
under warranty.
J. Foot Plate Jack:
Connect one end of the foot plate
cable cord and the other end to the dual foot plate.
K. Buzzer Volume Adjustment:
Turn the trimpot
clockwise to increase the buzzer volume and
counter-clockwise to decrease the volume.