Desco 19784 Скачать руководство пользователя страница 2

DESCO WEST

 - 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178

DESCO EAST

 - One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Website: 

Desco.com

TB-3046

 Page 2 of 4

© 2016 DESCO INDUSTRIES, INC.

Employee Owned

Features and Components

4.  Use one 5 pound electrode on the other test lead 

and place it at the center of the surface.

5.  Set the Test Voltage Button to AUTO.  Press and 

hold the the TEST button until the measurement is 

displayed (see Figure 3).

6.  Perform additional measurements by placing the 

electrode on the most commonly used or worn 

areas.

CAUTION: If there is a current limiting resistor in the 

worksurface and the worksurface resistance is lower, 

the measurement will primarily be the resistance of the 

resistor.  It is recommended to measure RTT particularly 

if the material color is black.

A. Analog Display:

 Displays surface resistance 

measurements from 1 x 10

3

 - 1 x 10

13

 ohms.

B. Resistance Property LEDs:

 Color-coded LEDs that 

provide quick-check resistance indicators.

C. Test Button:

 Hold this button down to operate the 

Analog Surface Resistance meter.

D. Low Battery LED:

 Illuminates when the battery 

power drops to 4.0V (±0.1V).

E. Test Voltage Button:

 Test voltage will automatically 

switch from 10V to 100V when set to AUTO.  Test 

voltage will stay at 10V HOLD when set to 10V.

Operation

Compliance Verification Test Procedure Guideline

The ESD Association lists test procedures and 

troubleshooting tips in Compliance Verification ESD 

TR53.

NOTE: The test kit can be used to measure RTG and 

RTT of shelves, garments, floor and cart worksurfaces 

using test procedures similar to worksurfaces and foot 

grounders.

MEASURE WORKSURFACE RESISTANCE TO 

GROUND (RTG)

1.  Do not clean the surface.

2.  Remove all ESD sensitive items from the surface 

and items that might interfere with the test.

3.  Connect one lead banana plug to ground.

Figure 2. Analog Surface Resistance Meter features and 

components

A

B

E

D

C

Figure 3. Using the test leads and one 5 pound electrode 

to measure RTG

MEASURE WORKSURFACE RESISTANCE POINT-TO-

POINT ON THE SURFACE (RTT)

1.  Do not clean the surface.

2.  Remove all ESD sensitive items from the surface 

and items that might interfere with the test.

3.  Use two 5 pound electrodes and place them 10" 

apart on the most frequently used area of the 

surface (2" from any edge, 3" from any groundable 

point).

4. 

If the most used area of the surface is not obvious, 

use two points near the center of the surface.

5.  Set the Test Voltage Button to AUTO.  Press and 

hold the TEST button until the measurement is 

displayed (see Figure 4).

Содержание 19784

Страница 1: ...irements to be verified the measurement limits and the frequency at which those verifications shall occur The Compliance Verification Plan shall document the test methods and equipment used for process monitoring and measurements If the test methods used by the Organization differ from any of the standards referenced in the document then there must be a tailoring statement that is documented as pa...

Страница 2: ...tage will automatically switch from 10V to 100V when set to AUTO Test voltage will stay at 10V HOLD when set to 10V Operation Compliance Verification Test Procedure Guideline The ESD Association lists test procedures and troubleshooting tips in Compliance Verification ESD TR53 NOTE The test kit can be used to measure RTG and RTT of shelves garments floor and cart worksurfaces using test procedures...

Страница 3: ...d be a good starting point Per ANSI ESD S4 1 Clean the electrodes with a minimum 70 isopropanol water solu tion Make sure conductive pads are dry prior to use The Analog Surface Resistance Meter requires little maintenance and there are no user serviceable parts If your unit requires service beyond cleaning the electrodes or replacing the batteries please contact Desco Customer Service RECOMMENDED...

Страница 4: ...3 to 1 x 1013 ohms 10 Volts complies with ANSI ESD S4 1 1 x 106 to 1 x 1013 ohms 100 Volts complies with ANSI ESD S4 1 Accuracy 1 2 decade Power Supply 9V alkaline battery Operating Temperature 41ºF to 85ºF 5ºC to 30ºC Environmental Requirements Indoor use only at altitudes less than 6500 ft 2 km Maximum relative humidity of 80 up to 85 F 30 C Meter Dimensions 4 5 x 2 8 x 2 1 11 cm x 7 cm x 5 cm M...