Installation
1. Locate and appropriate AC outlet near the
Dual-Wire Dual Operator Monitor, and test it for
proper wiring and grounding prior to use. The Desco
AC Outlet Analyzer or similar test equipment may
be used to verify the outlet’s functionality.
2. Determine the mounting locations of the operator
remotes. Be sure to install the remotes at a distance
that enables the 10 foot leads to reach the back of
the monitor.
3. Install tinned wire ends of the mat (must be
grounded seperately) cords to their appropriate
screw terminal block located at the back of the
monitor.
4. Install the tinned wire end of the green and yellow
moniitor ground cord to the ground terminal located
at the back of the monitor. Install its ring terminal
to an appropriate ground point. Be sure to use a
different ground point than the one used for the
mats. The face plate screw of a grounded AC wall
outlet may provide a convenient connection point.
5. Route the mat cords from the back of the monitor to
the snaps on the worksurface mats.
6. Insert the operator remote cables into their
appropriate jacks located at the back of the monitor.
The white cable is for operator #1. The black cable
is for operator #2.
7. Connect the power adapter to the power jack
located at the back of the monitor. Plug the power
adapter into a proper AC power outlet. The monitor
is now powered.
Operation
1. Monitoring of the operators will remain in the
STANDBY condition until a wrist cord is plugged
into the operator remote. STANDBY mode is
indicated by a blinking yellow operator LED.
2. Plug a wrist strap cord, not attached to the
wristband, into the monitored jack labeled WRIST
STRAP MONITOR located on the remote. This
automatically activates the selected operator
channel. The corresponding operator LED should
illuminate red and the alarm should sound on the
monitor.
3. Remove the charges from your body by making
contact with a properly grounded ESD worksurface.
4. Snap the cord to the wristband, and fit it snugly
onto your wrist. This should silence the audible
alarm and cause the corresponding operator LED
to switch from red to green. If this does not happen,
examine the wrist cord for continuity or damage and
your wrist band to ensure that it is securely fit. If you
have dry skin, apply an approved dissipative hand
Menda Reztore® ESD Hand Lotion
.
5. The AUX GND jack located on the operator remote
is a grounded and unmonitored connection for
guests, or other equipment grounds. It must be used
with a single-wire Banana plug style cord.
10mm snap needs to pierce
and clinch bottom side of
mat. Snap needs to be at
least 12" apart or 72" max.
10mm snap needs to pierce
and clinch bottom side of
mat. Snap needs to be at
least 12" apart or 72" max.
OPERATOR 1
WORKSURFACE
OPERATOR 2
WORKSURFACE
10mm PUSH &
CLINCH SNAP
10mm PUSH &
CLINCH SNAP
BENCH
GROUND
MAT 1 WIRING
WHITE CABLE
MAT 2 WIRING
BLACK CABLE
WRIST
STRAP
MONITOR
WRIST
STRAP
MONITOR
ELECTRIC
GROUND
Screw allows ground cord to
be bolted to mat; keeps cord
from disconnecting.
Figure 3. Installing the Dual-Wire Dual Operator Monitor
or
or
OPERATOR 2
REMOTE JACK
BLACK CABLE
OPERATOR 2
REMOTE JACK
WHITE CABLE
Figure 4. Using the Dual-Wire Dual Operator Monitor