Desco 19587 Скачать руководство пользователя страница 2

TB-2079

 Page 2 of 4

DESCO WEST

 - 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178 • Fax (909) 627-7449 

DESCO EAST

 - One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Fax (781) 575-0172 • Web Site: 

Desco.com

IMPORTANT NOTE: User should exercise caution when using 

any compressed air device.

Figure 2. Connecting the optional filter. (Available as item #60355)

Electrical Requirements

The Ion Python and Neutralizing Hand Gun must be connected to 

a properly grounded receptacle for the units to operate properly. It 

is recommended that the AC outlet be checked for proper wiring 

and grounding.

Do not under any circumstances remove the ground pin from 

the plug of these units.
NOTE:  Grounding of these units is necessary not only 

to ensure that they operate properly, but to eliminate the 

possibility of an electrical shock

.

Operation

Turn on unit with switch on the front panel. The green light 

indicates that the air nozzle is ready for use. Point nozzle at object 

to be cleaned or neutralized. 

For the Neutralizing Hand Gun, push button on the nozzle body 

to initiate the flow of air and neutralizing ions. Best results are 

normally obtained when holding the nozzle within 2 or 3 feet of the 

item being neutralized; hold the nozzle closer when required.

NOTE: Unit is not designed for continuous duty.

A needle valve is located on the back of the unit for fine 

adjustments to the air flow, or for shutting off the air to the nozzle. 

Airflow on the unit can be adjusted from a gentle blow to a strong 

blast, allowing for use in most applications. Do not obstruct the 

air jet with fingers or other objects.  Do not force any object into 

the air jet hole; this action can easily damage the emitter pin and 

prevent the controller from producing the ionization necessary for 

neutraliz ing static charges.
The ion balance is affected by many fac tors, such as distance, air 

flow, humidity, and emitter contamination. Therefore, before using 

this device around components and assemblies which are highly 

sensitive to ESD, it is recom mended that the user thoroughly 

evaluate the application prior to its use. Avoid sharply bending or 

crushing the black convoluted tubing under feet, rolling chairs or 

other furniture.

 

IMPORTANT NOTE: These air nozzles are not explosion proof. 

Do not use in environments where volatile materials are 

present.

Desco solid-state electronic equipment is compact and rugged but 

should be treated as sensitive electronic equipment. With proper 

installation and a continued preventive maintenance program you 

will ensure the proper performance of the unit.

Theory of Operation

The Ion Python and Neutralizing Hand gun employ high voltage 

AC to create a balanced ion field. AC systems utilize emitters 

that are switched rapidly between positive and negative high 

voltage, usually at the power line frequency (50/60 Hz). The 

emitter is located at the end of the nozzle. This emitter pro duces 

large amounts of positive and negative ions, which mix with the 

air supply and create a highly effective neutralizing field.  Any 

material within this field will be neutralized rapidly. The air nozzles 

also eliminate contamination by dislodging dust and debris 

which is attracted to a material’s surface by static charges. Once 

static charges are neutralized, dust particles and other forms of 

contamination are freed and carried away by the air stream. Desco 

ionizers meet the ANSI/ESD S20.20 minimum recommended 

technical requirement range of less than ±50 volts voltage offset 

tested in accordance with ANSI EOS/ESD S3.1.  Air Nozzle 

Ionizers provide ±20 volt balance.

Maintenance

“As with all ionizers, periodic maintenance will be needed to 

provide optimum performance.” (Reference: IEC 61340-5-2:1 

paragraph 5.2.9).

The frequency of monitoring ionizers really depends on how and 

where they are used.  Since the majority of them use a fan to 

transport the ions to the working area, the cleanliness of the air 

directly affects their performance over time and how often the 

emitters should be cleaned.
EIA-625 recommends checking ionizers every 6 months, but 

this may not be suitable for many programs particularly since an 

out-of-balance may exist for months before it is checked again. 

ANSI/ESD S20.20 paragraph 6.1.3.1 Compliance Verification 

Plan Requirement states: “Test equipment shall be selected to 

make measurements of appropriate properties of the technical 

requirements that are incorporated into the ESD 

program plan.”  

And paragraph 6.1.3.2. Compliance Verification Plan Guidance 

states: “In addition to internal audits, external audits (Organization 

and supplier of ESDS items) should be performed to ensure 

compliance with planned requirements. Verifications should 

include routine checks of the Technical Requirements in the Plan.  

The frequency of verification checks should be based on the 

control item usage, its durability and associated risk of failure.”

Under normal conditions, the ionizer will attract dirt and dust 

(especially on the emitter electrodes). To maintain optimum 

performance, cleaning 

must 

be performed on a regular basis. The 

electrodes should be cleaned at least every six months. However, 

more frequent cleaning may be required if used in environments 

with more contaminants.

Air supply

conection

Needle 

valve

Figure 3.  Airflow adjustment valve.

© 2010 DESCO INDUSTRIES INC.

Employee Owned

Filter (when used)

Содержание 19587

Страница 1: ...rge control on conductors or people Reference IEC 61340 5 2 1 paragraph 5 2 9 The Ion Python Neutralizing Hand Gun is NIST calibrated They come equipped with universal IEC cord connectors Neutralizing Ion Python Hand Gun Operation and Maintenance NOTE These units are not recommended for continuous use IONIZER SELECTION ANSI ESD S20 20 paragraph 6 1 1 2 ESD Control Program Plan Guidance states The ...

Страница 2: ...heory of Operation The Ion Python and Neutralizing Hand gun employ high voltage AC to create a balanced ion field AC systems utilize emitters that are switched rapidly between positive and negative high voltage usually at the power line frequency 50 60 Hz The emitter is located at the end of the nozzle This emitter pro duces large amounts of positive and negative ions which mix with the air supply...

Страница 3: ...er to maintain the optimum performance of your unit the following maintenance procedures must be performed on a regular basis Make sure that the air supply is clean and free of contamination and moisture Drain compressor tank and filters periodically The filters may require draining several times daily depending on your compressed air system The fuse may be replaced by removing the power cord at t...

Страница 4: ...emperature 5 C to 40 C Maximum relative humidity 80 for temperatures up to 31 C decreasing linearly to 50 relative humidity at 40 C Mains supply voltage fluctuations up to 10 of the nominal voltage Transient overvoltages typically present on the mains supply Applicable rated pollution degree is 2 Degree of ingress protection is IP10 Adjustment screw 2010 DESCO INDUSTRIES INC Employee Owned MFG Spe...

Страница 5: ... 401 Building No 5 JiuGe Business Center Lane 2301 Yishan Rd Minhang District Shanghai China Sales Direct 86 21 6401 6692 Email amall ameya360 com QQ 800077892 Skype ameyasales1 ameyasales2 Customer Service Email service ameya360 com Partnership Tel 86 21 64016692 8333 Email mkt ameya360 com ...

Отзывы: