Wrist Straps
Grounding, Testing and Maintenance

Wrist Straps per ANSI/ESD S20.20
“All personnel shall be bonded or electrically connected to 
the grounding / equipotential bonding system when handling 
ESDS [ESD sensitive] items.”  “When personnel are seated 
at ESD protective workstations, they shall be connected to 
the grounding/equipotential bonding system via a wrist strap 
system.” [ANSI/ESDS20.20-2007 sections 8.1 and 8.2]

Location of Wrist Strap Ground Point

Wrist straps, ESD worksurfaces, and floor mats are to be 

grounded to remove electrostatic charges connected to a 

common point ground.

 

The common point ground should 

be connected with one ground cord to the “green wire” 

equipment ground.

March 2014

This may be accomplished in a variety of ways utilizing a 

common point ground block, a ground bus, or connecting 

directly to the nearest AC “green wire” equipment ground 

point. In a properly wired building, the nearest reliable 

equipment ground point will be ground or the center screw of 

the standard 110 VAC electrical outlet.

Each ESD workstation must be individually grounded to the 

ground bus or “green wire” equipment ground. Do not wire 

worksurfaces or other ESD devices in series or “daisychain” 

them. This can create unknown higher resistance to ground.

For a more detailed discussion of ESD grounding see Desco 

technical bulletin 

TB-2007

. For instructions on grounding 

Desco worksurface mats see technical bulletin 

TB-2000

.

  TECHNICAL BULLETIN TB-2005 

Test The Ground Before You Use It And Periodically 

Thereafter

Do not assume that any AC electrical outlet is properly 

wired. Even if it was originally wired correctly it can become 

ungrounded due to corrosion and wear. Test the ground you 

intend to use before you hook up. We suggest using Desco’s 

item 

98132

 AC Outlet Analyzer and Wrist Strap Tester.

A Banana Jack Is Recommended

Almost all wrist strap manufacturers terminate wrist ground 

cords with banana plugs. This is because the banana plug 

and jack have proven to be a fast and reliable way to attach 

to ground. If you must use another method such as snaps or 

alligator clips, due to your particular environment, be sure to 

test the connections often.

Note: Many wrist strap users clip the wrist cord to the edge 

of an ESD  mat. This process is not recommended as it can 

increase the total system resistance to ground to over the 

35 megohm required limit of ANSI/ESD S20.20. “Wrist strap 

ground cords must be connected to a groundable point or an 

equipotential bonding point. Do not connect to a snap on a 

dissipative mat unless it is the groundable point for the mat. 

Do not clip a wrist strap to the edge of a dissipative mat.” 

[ESD Handbook TR20.20 section 5.3.2.7]  Best industry 

practice is that ESD Ground Connections should be firm 

fitting connecting devices such as metallic crimps, snaps 

and banana plugs shall be connected to designated ground 

points. Use of alligator clips is not recommended.

Compliance Verification of the Ground System

Set up a schedule to be sure that all ESD grounds are 

inspected and tested periodically, every six months for 

example.

Testing the Wrist Strap

The best test of the wrist strap system is while it is worn. This 

includes all three components: the wrist band, the ground 

cord (including current limiting resistor), and the interface 

with the wearer’s skin.

BENCH MAT

WRIST STRAP

WITH COIL CORD

COMMON POINT 

GROUND #09826

FLOOR MAT

FLOOR MAT 

GROUND #09814

Figure 1. Common point ground for each workstation

Figure 2. “Green wire” equipment ground

NO

WARNING!

DO NOT

DAISY CHAIN

THE WRIST STRAP!

GREEN

WIRE

EQUIPMENT

GROUND

09740

09835/09836

Figure 3. Desco’s 

09740

 / 

09741

 dual bench mount and 

09835

 / 

09836

 quad common point ground cord are two easy 

ways to provide multiple banana jacks at any workstation.