Desco 19258 Скачать руководство пользователя страница 6

TB-3072

 Page 6 of 6

© 2018 DESCO INDUSTRIES INC

Employee Owned

DESCO WEST 

- 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178

DESCO EAST 

- One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Website: 

Desco.com

Specifications

Input Voltage and 

Frequency

(External Adapter)

AC/DC Power Adapter
Power Input: 

100-240VAC, 50/60 Hz
Power Output: 

24VDC @ 150mA
Cable Length: 

5 ft. (1.5 m)

Operating Temperature 50 to 95°F (10 to 35°C)
Environmental 

Requirements

Indoor use only at altitudes 

less than 6500 ft. (2 km)
Maximum relative humidity 

of 80% up to 85°F (30°C) 

decreasing linearly to 50% @ 

85°F (30°C)

Dimensions

2.77" L x 2.08" W x .90" H

(70 mm x 53 mm x 23 mm)

Weight

0.1 lbs. (0.05 kg)

Operator Test Range* 500 kilohms to 10 megohms 

impedance

Worksurface Test 

Limit**

500 megohms (±20%)

Operator Test Voltage 1.2V peak-to-peak @ 1.2µA, 

open circuit

Worksurface Test 

Voltage

5 to 7.5V, open circuit

Alarm Response Time <50 ms
Country of Origin

United States of America

*This cannot be verified with standard DC test 

equipment.  The continuous monitor is an impedance 

sensing device, and the limits are determined by the 

magnitude and angle of the impedance.
**The worksurface mat must have a conductive 

layer such as Dual Layer Rubber or Dissipative 

3-Layer Vinyl with conductive buried layers.  Desco 

workstation monitors are not recommended for use with 

homogeneous matting.
ANSI/ESD S20.20 requires the use of a surface 

resistance meter for periodic verification of a 

worksurface's resistance-to-ground (Rtg). Constant 

monitors may not be used as a substitute for this 

requirement.

Limited Warranty, Warranty Exclusions, Limit 

of Liability and RMA Request Instructions

See the Desco Warranty - 

Desco.com/Limited-Warranty.aspx

Содержание 19258

Страница 1: ...he continuous or constant monitor The test voltage creates a sine wave that the monitor circuit compares to established patterns By monitoring the distortions or shape of the sine wave Wave Distortion Technology determines if the monitored circuit is complete the operator is in the circuit and the total equivalent DC resistance is within specifications Wave Distortion Technology produces a very fa...

Страница 2: ...ashers 2 Flat Head Screw 6 32 x 1 4 1 Power Adapter 24VDC North America Plug 1 Certificate of Calibration 19243 Mini Monitor Universal Power Adapter 1 Mini Monitor 2 Countersunk Washers 2 Flat Head Screw 6 32 x 1 4 1 10mm Interchangeable Park Snap 1 10mm Operator Jack Adapter 1 Power Adapter 24VDC IEC Inlet 1 Certificate of Calibration Figure 2 North American power adapter included with the 19239 ...

Страница 3: ...park a wrist strap when leaving the workstation without creating a false alarm Touch the park snap and the monitor s audible alarm will disable for approximately 10 seconds Use this time to disconnect the wrist cord from the wristband and attach it to the park snap or remove the banana plug from the jack Upon returning to the workstation and disconnecting the wrist cord from the park snap the oper...

Страница 4: ...ark snap and 10mm banana jack adapter for operators who use wrist cords with 10mm terminations Use the park snaps knurled rims to unscrew the 4mm park snap from the monitor and install the 10mm park snap to the monitor Plug the 10mm operator jack adapter into the monitor s operator jack Installation 1 Remove the Mini Monitor from the carton and inspect for damage 2 Locate an appropriate AC outlet ...

Страница 5: ... 2 Snap the wrist cord to the wristband 3 Plug the wrist cord into the operator jack The green operator LED will illuminate This indicates that the operator is properly grounded 4 If this does not happen examine the wrist cord for continuity or damage and the wristband to ensure that it fits securely If you have dry skin apply an approved dissipative hand lotion such as Menda Reztore ESD Hand Loti...

Страница 6: ... megohms 20 Operator Test Voltage 1 2V peak to peak 1 2µA open circuit Worksurface Test Voltage 5 to 7 5V open circuit Alarm Response Time 50 ms Country of Origin United States of America This cannot be verified with standard DC test equipment The continuous monitor is an impedance sensing device and the limits are determined by the magnitude and angle of the impedance The worksurface mat must hav...