Desco 19249 Скачать руководство пользователя страница 2

DESCO WEST 

- 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178

DESCO EAST 

- One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Website: 

Desco.com

TB-3070

 Page 2 of 3

© 2015 DESCO INDUSTRIES, INC.

Employee Owned

E. Low Battery LED:

 LED illuminates when the battery 

needs to be replaced.

F. 6 Foot Coiled Cord: 

Insulation black color PVC

G. Banana Plug:

 Industrial Standard .175" (4.4 mm) 

Banana Plug, fits banana jack ≥ .157".

Operation

USING THE TESTER

1.  Use the slide switch to select a test range. 
2.  Connect the coil cord banana plug end to known 

ground.  Use adapters where needed.  NOTE: The 

Desco Low Resistance Tester may be used with an 

outlet polarity checker such as the Desco 

19219

 to 

determine a known ground. 

3.  Connect or touch the tester end to a banana jack or 

other equipment that is being tested for resistance 

to ground. 

4.  Press and hold the test button. 
5.  An audio and visual indication will activate for a 

PASS condition. 

6.  A FAIL condition is indicated when the buzzer does 

not sound and the PASS does not illuminate.

Figure 3.  Testing ground points with the 

19249

 tester

Example of Test Range Uses

<1 OHM Range 
  ESD Technical element Grounding Conductors: 

  Banana Jacks, Grounding Blocks, Mat Ground Cords  

 

ANSI/ESD S6.1 Grounding, sections 6.4 Technical 

  Elements,

 6.4.1, 6.4.2 and 6.4.3

 

 

New AC Powered Hand Tools

 

ESD Handbook ESD TR20.20 section 5.5.2.2

  Electrical Hand Tools 

<2 OHM
  Soldering Irons

 

ESD Handbook ESD TR20.20 section 5.5.2.2

  Electrical Hand Tools

 

 

Other AC Powered Hand Tools

 

ESD Handbook ESD TR20.20 section 5.5.2.2

  Electrical Hand Tools

<10 OHM
  Soldering iron verification

  ESD Handbook ESD TR20.20 section 5.5.2.2 

  Electrical Hand Tools

 

  Auxiliary grounds (ground rods)

  ANSI/ESD S20.20*

*ANSI/ESD S20.20 requires <25 ohms from the 

Auxiliary Ground to the Equipment Grounding 

Conductor.  The Desco Low Resistance Tester only 

tests to <10 ohms.  In cases of a no pass result with 

the Low Resistance Tester when testing an Auxiliary 

Ground, an Ohm meter should used to determine the 

actual resistance from the Auxiliary Ground to the 

Equipment Grounding Conductor.

Figure 4.  Testing a soldering iron with the 

19249

 tester

Figure 5.  Testing auxiliary ground with the 

19249

 tester

Отзывы: