Features and Components
Multi-Mount Continuous Monitor, 220VAC
1 Multi-Mount Continuous Monitor
1 24VDC Power Adapter without Power Cord
1
1 6' Mat Monitor Cord (Black)
1 6' Mat Ground Cord (Green and Yellow)
2 Push and Clinch Snaps
2 Mounting Screws
2 Countersink Washers
1 Set of Hook and Loop Fasteners
1 Zip Tie
1 Certificate of Calibration
NOTE: The power cord must be purchased separately
. See
the following EMIT items for available power cords:
Item
Power Cord Type
Europe
United Kingdom
Figure 2. 220VAC power adapter included with the
Desco
and
Multi-Mount Continuous
Monintors. Power cord sold separately.
A
B
I
H
G
C
D
E
Figure 3. Multi-Mount Continuous Monitor features and
components
F
A. Status LEDs:
When the green LED is illuminated,
the operator is properly grounded. When the red LED is
illuminated, the operator is not properly grounded.
B. Monitored Operator Jack:
Where the operator
inserts the wrist cord banana plug.
C. Worksurface Ground LEDs:
When the green LED
is illuminated, the worksurface mat is properly grounded.
When the red LED is illuminated, the worksurface mat is
not properly grounded.
D. Operator Ground LEDs:
When the green LED is
illuminated, the operator is properly grounded. When
the red LED is illuminated, the operator is not properly
grounded.
E. 4mm Parking Snap:
When touched by the operator,
this snap will deactivate the alarm for six seconds. This
allows time for the operator to disconnect the coil cord
from the wrist band and park it on this snap. While
parked, the coil cord disables the alarm, allowing the
operator to leave the workstation. The OPERATOR
GROUND LED will remain off while the cord is parked.
Upon returning and removing the coil cord from the
parking snap, the operator has six seconds to hook up
to the wrist band before the alarm sounds.
F. Cable Tie Mount:
Pair with the included zip tie to
secure the nearby power adapter cord and reduce strain
on its plug.
G. Power Jack:
Connect the power adapter here.
H. Mat Connection:
Monitors worksurface mat.
NOTE: To disable worksurface monitoring, shunt this
terminal to the neighboring GND terminal with bus wire.
I. Mat Ground:
Grounds worksurface mat.