background image

TB-3028

 Page 4 of 4

© 2011 DESCO INDUSTRIES INC.

Employee Owned

WORK SURFACE CHANNEL

The Multi-Mount Continuous Monitor monitoring circuitry is 

sufficiently sensitive to detect extremely low current when 

used with a worksurface with a conductive layer.

Specifications

Test range of monitored circuit  500K - 10M ohms†

Operating Voltage 

 

  

19226

 

120 VAC, 50/60 Hz

  

19227

 

220 VAC, 50/60 Hz

Work Surface Range 

10 Megohms

Wrist strap open circuit voltage  1.2 volts peak to peak @  
 

1-2 MicroAmps

Mat test open circuit voltage 

5 to 7.5 volts

Response time to alarm 

<50 ms

Operating Temperature 

0 - 40°C

Size  

3.86"L x 2.10"W x .910"H

† This cannot be verified with standard DC test equipment. 
The continuous monitor is an impedance sensing device 
and the limits are determined by the magnitude and angle 
of the impedance.

Figure 5. Using the Multi-Mount Continuous Monitor

Note: Work surface must have a conductive layer such 
as Dual Layer Rubber or Dissipative 3-Layer Vinyl or 
Micastat® Dissipative Laminate with conductive buried 
layers. Desco Continuous Monitors are not recommended 
for use with homogeneous matting.

DESCO WEST

 - 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178 • Fax (909) 627-7449 

DESCO EAST

 - One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Fax (781) 575-0172 • Web Site: 

Desco.com

Limited Warranty

Desco expressly warrants that for a period of one (1) year from the 

date of purchase Desco Continuous Monitors will be free of defects in 
material (parts) and workmanship (labor).  Within the warranty period, 
a credit for purchase of replacement Desco Continuous Monitors, 
or, at Desco’s option, the Continuous Monitor will be repaired or 
replaced free of charge.  If product credit is issued, the amount will 

be calculated by multiplying the unused portion of the expected one 

year life times the original unit purchase price. Call our Customer 

Service Department at 909-627-8178 (Chino, CA) or 781-821-8370 

(Canton, MA) for a Return Material Authorization (RMA) and proper 
shipping instructions and address. Please include a copy of your 
original packing slip, invoice, or other proof of date of purchase. Any 
unit under warranty should be shipped prepaid to the Desco factory. 

Warranty replacements will take approximately two weeks.

If your unit is out of warranty, call our Customer Service Department 

at 909-627-8178 (Chino, CA) or 781-821-8370 (Canton, MA) for a 

Return Material Authorization (RMA) and proper shipping instructions 
and address. Desco will quote repair charges necessary to bring your 
unit up to factory standards.

Warranty Exclusions

THE FOREGOING EXPRESS WARRANTY IS MADE IN LIEU 
OF ALL OTHER PRODUCT WARRANTIES, EXPRESSED AND 
IMPLIED, INCLUDING MERCHANTABILITY AND FITNESS 
FOR A PARTICULAR PURPOSE WHICH ARE SPECIFICALLY 

DISCLAIMED. The express warranty will not apply to defects or 

damage due to accidents, neglect, misuse, alterations, operator error, 
or failure to properly maintain, clean or repair products.

Limit of Liability

In no event will Desco or any seller be responsible or liable for any 
injury, loss or damage, direct or consequential, arising out of the 
use of or the inability to use the product. Before using, users shall 
determine the suitability of the product for their intended use, and 
users assume all risk and liability whatsoever in connection therewith

.

Maintenance and Calibration

The Multi-Mount Continuous Monitor is solid state and 
designed to be maintenance free. The 

19226 

19227

 is 

calibrated to NIST traceable standards. There are no user 
adjustments neccesary. Because of the wave distortion 
sensing nature of the test circuit, special equipment is 
required for calibration. We recommend that calibration 
be performed using the Desco 

98220

 Continuous 

Monitor Calibration Unit. The Calibration Unit is a most 
important product which allows the customer to perform 
NIST traceable calibration on continuous monitors. The 

98220

 is designed to be used on the shop floor at the 

workstation, virtually eliminating downtime, verifying that 
the continuous monitor is operating within tolerances.  Per 
ANSI/ESD S20.20 Paragraph 6.2.2.2 Personnel Grounding 
Guidance, “Personnel should check constant monitoring 
devices (when used) to ensure that they are functional and 
operating before ESDS products are handled. In addition, 
constant monitoring devices should be functionally checked 
periodically to ensure that they are operating as designed.”

Отзывы: