Desa VV42ENA1 Series Скачать руководство пользователя страница 17

111907-01A

For more information, visit www.desatech.com

For more information, visit www.desatech.com

17

17

Va

ria

ble

Fa

n S

wi

tch

 

W

hite

W

hit

e

Bla

ck

Gr

ee

n

On

11

0/1

15

 

V.

A.

C.

Blower

Motor

Bla

ck

Bla

ck

Bla

ck

Of

f

 CAUTION: Never touch the blower wheel while in

operation.

4.

Be certain that all wire terminals are securely attached to ter-
minals on blower motor and that the screw retaining the green
ground wire is tight.

5.

Mount speed control box to switch bracket by placing the plastic
control shaft forward through the opening in the switch bracket
(see Figure 26).

6.

While supporting speed control, secure control shaft with lock
nut by pushing and turning lock nut with pliers clockwise until it
is tight against front panel. Place control knob provided on shaft.

7.

Turn on power to duplex outlet if previously turned off per the
warning in column 2, page 16.

8.

Plug in blower power cord.
a. If your firebox is installed as a freestanding unit with an

accessory mantel, determine whether the power cord will
exit the left side or the right side of the firebox. Route power
cord through exit hole and plug the power cord into a wall
receptacle near the firebox.

b. If your firebox installation is recessed and/or pre-wired,

plug the power cord into the duplex outlet provided. Refer
to your firebox owner’s manual for instructions on wiring
the duplex outlet.

9.

Check to make sure that the power cord is completely clear of the
blower wheel and that there are no other foreign objects in blower
wheel. Turn blower on and check for operation. Turn blower off
by turning knob fully counterclockwise before continuing.

10. Peel off the backing paper and stick the supplied wiring dia-

gram decal on the firebox bottom approximately 12" in front
of the blower (see Figure 27).

Figure 25 - Blower Model BK

Magnetic Strips

Exhaust
Port

Screw

Green
Ground Wire

Spade Terminals

Figure 26 - Attaching Speed Control to Firebox

Side View

Lower Firebox
Cavity

Blower
Location

Figure 27 - Location of Wiring Diagram Decal (Model May Vary
From Illustration)

Wiring Diagram Decal
12" in Front of Blower

FIREPLACE INSTALLATION

Installing Optional Blower Accessory (Cont.)

FIREPLACE INSTALLATION

Continued

Speed Control

Control
Shaft

Locknut

Control
Knob

Switch
Bracket

Blower
Plug-In

Duplex Outlet
(Located underneath
firebox floor against
lower right outside wall)

Содержание VV42ENA1 Series

Страница 1: ...ent alteration service or maintenance can cause injury orpropertydamage Refertothis manual for correct installation and operational procedures For assistance or additional infor mation consult a quali...

Страница 2: ...tem Itbringsinfreshairforcombustionthroughtheouterpipeand combustion gases are exhausted through the inner pipe If the glass door assembly and venting pipe are not properly seated connected and sealed...

Страница 3: ...se this fireplace to cook food or burn paper or other objects 13 Do not use any solid fuels wood coal paper cardboard etc in this fireplace Use only the gas type indicated on fireplace nameplate 14 Th...

Страница 4: ...he location of your fireplace follow these rules Do not connect this fireplace venting to a chimney flue serving a separate solid fuel burning fireplace or appliance Due to high temperatures do not lo...

Страница 5: ...s tible mantels may discolor PRE INSTALLATION PREPARATION Continued NOTICE This fireplace is intended for use as supple mental heat Use this fireplace along with your pri mary heating system Do not in...

Страница 6: ...inlet 72 inches 1829mm minimum L clearance above paved side walk or a paved driveway located on public property 84 inches 2133mm minimum M clearance under veranda porch deck 12 inches 305mm minimum N...

Страница 7: ...ing ceilings or attic spaces Install horizontal venting with a 1 4 rise for every 12 of run toward the termination VENTING INSTALLATION INSTRUCTIONS NOTICE Read these instructions completely be fore a...

Страница 8: ...f adjacent pipes Push pipe sections together and twist one section clockwise approxi mately one quarter turn until the sections are fully locked see Figure 8 Note Horizontal runs of vent must be sup p...

Страница 9: ...off Position the standoff cap assembly in the center of the 10 3 4 square hole and attach to exterior wall with wood screws provided see Figure 11 The siding standoff must sit flush against the exteri...

Страница 10: ...chart with critical minimum and maximum dimensions which MUST be met IMPORTANT Rememberthatahorizontalrunofventingmust have a 1 4 rise for every 12 of run toward the termination Figure 13 Typical Hori...

Страница 11: ...throughwall over 12 horizontal pipe Basement installation where one foot clearance from ground to termination is possible SNORKEL TERMINATION INSTALLATION Recommended Applications Installations requir...

Страница 12: ...max 12 max 7 min 6 max 18 max 8 min 8 max 20 max 20 max 8 max 20 max 45 Elbow Figure 18 Horizontal Termination Configuration for Venting Using Two 90 Elbows with Termination at 90 with Fireplace Figu...

Страница 13: ...a above is a room install firestop above framed hole 2 Assemble the desired lengths of pipe and elbows necessary to reach from the fireplace flue up through the firestop Be sure all pipe and elbow con...

Страница 14: ...wo90 Elbows Vertical Round High Wind Termination Shown VENTING INSTALLATION INSTRUCTIONS Installation for Vertical Termination Cont Venting with Two 90 Elbows Vertical V Horizontal H1 Horizontal H2 5...

Страница 15: ...s for V42 and VV42 Series Note Install restrictor into inner collar of fireplace as shown 45 Elbow PARTS LISTS FOR VENTING KITS AND COMPONENTS FOR V42 AND VV42 SERIES DESA 5 8 Pipe Vent Kits Number De...

Страница 16: ...1 01798 Vertical Round High Wind Termination 1 FIREPLACE INSTALLATION VENTING INSTALLATION INSTRUCTIONS Parts Lists for Venting Kits and Components for V42 and VV42 Series Cont Parts Lists for Venting...

Страница 17: ...ide of the firebox Route power cord through exit hole and plug the power cord into a wall receptacle near the firebox b If your firebox installation is recessed and or pre wired plug the power cord in...

Страница 18: ...til it clicks off If the blower is ON and has been running with the fireplace operating the blower will continue to run for a short time after the fireplace has been turned off As the thermal switch c...

Страница 19: ...n must include an equipment shutoff valve union and plugged 1 8 NPT tap Locate NPT tap within reach for test gauge hook up NPT tap must be upstream from fireplace see Figure 31 IMPORTANT Install main...

Страница 20: ...t provided 1 Open lower louver door panel by gently pulling forward 2 Route flexible gas line provided by installer from equipment shutoff valve to fireplace Route flexible gas supply line through one...

Страница 21: ...louvers outward To install or replace items removed simply reverse the procedures above Figure 36 Removing Louver Panel Louver Panel CAUTION Wear gloves and safety glasses while handling or removing...

Страница 22: ...et cool before installing brick liner This brick liner kit is optional You may purchase brick liner from your local retailer or see Accessories page 37 CAUTION Always handle brick panels with two hand...

Страница 23: ...erly 8 Place lava rock along sides and front of firebox bottom in ar eas that are visible only It is not necessary to use all of the lava rock provided NOTICE Do not put lava rock on burner or under b...

Страница 24: ...eady to use 5 Close lower louver panel Figure 47 Installing the WRC Remote Receiver Fireplace Receptacle Remote Control Receiver Extension Cord Ignition Module Plug Figure 48 Installing Battery into B...

Страница 25: ...flame appears at pilot If lighting the appliance for the first time each season it may take several attempts before the supply gas can reach the pilot and main burners If the appliance will not stay l...

Страница 26: ...ve any dust dirt or other obstructions that will hinder the flow of air BURNER FLAME PATTERN Burner flames will be steady not lifting or floating Flame patterns will be different from unit to unit and...

Страница 27: ...be used CLEANING AND MAINTENANCE CAUTION Wear gloves and safety glasses while handling or removing broken glass Do not remove if glass is hot Keep children and pets away from glass WARNING Donotopera...

Страница 28: ...d repair 3 Remove debris and dirt inspect and clean any other possible obstructions 4 Contact your gas supplier to check pressure 5 Have a qualified technician replace pi lot line 6 Replace control va...

Страница 29: ...ial OBSERVED PROBLEM Fireplace produces a clicking ticking noise just after burner is lit or shut off Slightsmokeorodorduringinitialoperation Gas odor even when control knob is in OFF position Gas odo...

Страница 30: ...ILLUSTRATED PARTS BREAKDOWN Models V V42ENA 1 V V42ENSA 1 V V42ENHA 1 V V42EPA 1 V V42EPSA 1 V V42EPHA 1 ILLUSTRATED PARTS BREAKDOWN MODELS V V42ENA 1 V V42ENSA 1 V V42ENHA 1 V V42EPA 1 V V42EPSA 1 V...

Страница 31: ...nel Louver Assy 1 6 Fireplace Top 1 7 Fireplace Top Insulation 1 8 Fireplace Surround 1 9 109082 02 109082 02 109082 02 Heat Shield 1 10 108778 01 108778 01 108778 01 Log Set 1 10 1 109396 01 109396 0...

Страница 32: ...BREAKDOWN Models V V42ENA 1 V V42ENSA 1 V V42ENHA 1 V V42EPA 1 V V42EPSA 1 V V42EPHA 1 ILLUSTRATED PARTS BREAKDOWN BURNER ASSEMBLY FOR MODELS V V42ENA 1 V V42ENSA 1 V V42ENHA 1 V V42EPA 1 V V42EPSA 1...

Страница 33: ...07 Screw 10 32 x 1 4 PPH Zinc 4 16 26808 Valve Bracket 1 17 26827 Switch Bracket 1 18 11147 Screw 10 24 x 1 2 PPH Zinc 2 19 11186 Screw 8 32 x 1 Zinc 4 20 14115 Spade Tongue Connector 1 21 14120 Spade...

Страница 34: ...al gas supplier TECHNICAL SERVICE You may have further questions about installation operation or troubleshooting If so contact DESA s Customer Service Depart mentat1 866 672 6040 Whencalling pleasehav...

Страница 35: ...Completed College Completed Graduate School 13 Age of Purchaser Under 20 20 29 30 39 40 49 50 59 60 or Over 14 Buyer s total annual household income Under 15 000 15 000 to 19 999 20 000 to 34 999 35...

Страница 36: ...111907 01A For more information visit www desatech com For more information visit www desatech com 36 2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004 Postage Required TAPE TAPE...

Страница 37: ...ss FPD42P Filligree Panel Kit Platinum FPD42PB Filligree Panel Kit Polished Brass LOUVER TRIM KIT Rolled Louvers Only Not Shown LT42B Rolled Louver Trim Kit Brushed Brass LT42P Rolled Louver Trim Kit...

Страница 38: ...ansportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE...

Отзывы: