www.desatech.com
122274-01F
14
Figure 13 - Installing Gas Line and
Equipment Shutoff Valve (Model May
Vary From Illustration)
Gas Line Hole
Equipment
Shutoff Valves
(Install One)
INSTALLING GAS LINE
WARNING: A qualified ser-
vice person must connect heater
to gas supply. Follow all local
codes.
IMPORTANT:
See
Connecting to Gas Supply
in your log set owner’s manual for details on
gas hookup.
You may run the gas line from either side of
the firebox (see Figure 13). Decide which side
you want to run the gas line from.
Note: This is one option for installing shutoff
valve. Check local codes for equipment shut-
off valve location requirements.
BRICK PANEL INSTALLATION
IMPORTANT: Installation of brick
should be done after the fire-
place is placed in a permanent
location.
The brick housings are already installed on
the panels. When installing brick housing
panels into fireplace, wear gloves as edges
may be sharp.
1. Beginning with left side panel, place
panel, bottom edge first, at an angle into
fireplace. Secure to bottom of fireplace
with screws provided.
2. Install right side as left side in step 1 using
screws provided.
3. Install back panel and secure back to
sides and bottom of firebox with screws
provided.
4. Using self-tapping screws and a drill, place
screws into large holes in back and side
panels (see
Parts
, page 32), through wire
mesh and into firebox wrapper to secure.
Figure 14 - Hole in Side Panel to Attach
to Firebox Wrapper
Hole in
Side Panel
Figure 15 - Installing Bricks into Brick
Housings
INsTAllATIoN
Continued
BRICK INSTALLATION
Each brick housing is stamped with a number
(full size bricks are not stamped). These num-
bers will help identify the brick when installing.
It is important to install these bricks exactly as
instructed. Press brick firmly into brick housing
until it snaps. Groove line on side of brick will
come in contact with flange on the brick hous
-
ing. This secures brick into housing (see Figure
15). Smaller bricks may require a small portion
of furnace cement applied to back of brick to
secure it until grouting has been completed.
Bricks are packaged in separate boxes. The
brick matrixes on pages 15 through 27 show
how bricks are packaged and placed for each
size fireplace and the number of bricks per
box. There are 2 extra full bricks included in
Hearth Brick package.
Install bricks one section at a time starting with
hearth panel followed by the rear panel, left
panel and right panel. It is important to install
the bricks in sequence. Please note, full size
bricks are NOT stamped.