www.desatech.com
119677-01G
5
PRODUCT IDENTIFICATION
Figure 1 - Product Identification
Base Assembly
Control Knob Cover Log
Ignitor
UNPACkING
Log Set
LOCAL CODES
VUL18NV/PV and VUL24NV/PV
Base
Assembly
Ignitor
Log Set
Ignitor
Cover Log
Control Knob
VUL36NV/PV
Install and use heater with care. Follow all
local codes. In the absence of local codes,
use the latest edition of
The National Fuel
Gas Code, ANSI Z223.1/NFPA 54
*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
State of Massachusetts: The installation
must be made by a licensed plumber
or gas fitter in the Commonwealth of
Massachusetts.
Sellers of unvented propane or natural
gas-fired supplemental room heaters shall
provide to each purchaser a copy of 527
CMR 30 upon sale of the unit.
Vent-free gas products are prohibited for
bedroom and bathroom installation in the
Commonwealth of Massachusetts.
CAUTION: Do not remove data
plates from grate assembly. Data
plates contain important war-
ranty and safety information.
1. Remove logs and heater base assembly
from carton.
Note: Do not pick up heater base assem-
bly by burners. This could damage heater.
Always handle base assembly by grate.
2. Remove all protective packaging applied
to logs and heater for shipment.
3. Check heater for any shipping damage. If
heater is damaged call DESA Heating, LLC
at 1-866-672-6040 for replacement parts
before returning to dealer.
PRODUCT FEATURES
OPERATION
This heater is clean burning. It requires no
outside venting. There is no heat loss out a
vent or up a chimney. Heat is generated by
both realistic flames and glowing coals. This
heater is designed for vent-free operation with
flue damper closed. It has been tested and ap
-
proved to ANSI Z21.11.2 standard for unvented
heaters. State and local codes in some areas
prohibit the use of vent-free heaters. This heater
may also be operated as a vented decorative
(ANSI Z21.60) product by opening the flue
damper (Non-Thermostat Models Only).
SAFETY DEVICE
This heater has a pilot with an Oxygen Deple-
tion Sensing (ODS) safety shutoff system. The
ODS/pilot is a required feature for vent-free
room heaters. The ODS/pilot shuts off the
heater if there is not enough fresh air.
ELECTRONIC IGNITION SYSTEM
This heater has an electronic ignitor to light
pilot.