www.desatech.com
116746-01A
20
OPERATING FIREPLACE
Continued
Note:
If pilot does not stay lit, contact a
qualified service person or gas supplier for
repairs. Until repairs are made, light pilot
with match. To light pilot with match, see
Manual Lighting Procedure
.
7. Keep control knob pressed in for 30 seconds
after lighting pilot. After 30 seconds, release
control knob.
Note:
If pilot goes out, repeat steps 3
through 7. This fireplace has a safety inter-
lock system. Wait one (1) minute for system
to reset before lighting pilot again.
• If control knob does not pop out when
released, contact a qualified service person
or gas supplier for repairs.
8. Turn control knob counterclockwise
to desired heating level. The burners should
light. Set control knob to any heat level
between HI and LO.
CAUTION: Do not try to ad-
just heating levels by using the
equipment shutoff valve.
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Fireplace
Turn control knob clockwise
to the OFF
position.
Shutting Off Burners Only (pilot stays lit)
Turn control knob clockwise
to the
PILOT position.
Figure 28 - Pilot
Ignitor Electrode
Pilot Burner
THERMOSTAT CONTROL
OPERATION
You can set the thermostat control knob to any
comfort level between HI and LO. The thermo-
stat will gradually modulate the heat output
and flame height from higher to lower settings
or pilot, in order to maintain the comfort level
you select. The ideal comfort setting will vary
by household depending upon the amount of
space to be heated, the output of the central
heating system, etc.
Note:
Selecting the HI setting will cause the
burner to remain on without modulating down
in most cases.
MANUAL LIGHTING
PROCEDURE
1. Follow steps 1 through 5 under
Lighting
Instructions
, page 19.
2. Depress control knob and light pilot with
match.
3. Keep control knob pressed in for 30 seconds
after lighting pilot. After 30 seconds, release
control knob. Now follow step 8 under
Lighting Instructions
, column 1.
REMOTE CONTROL MODELS
FOR YOUR SAFETY
READ BEFORE LIGHTING
WARNING: If you do not fol-
low these instructions exactly,
a fire or explosion may result
causing property damage, per-
sonal injury or loss of life.
A. This appliance has a pilot which must be
lighted by hand. When lighting the pilot,
follow these instructions exactly.
B. BEFORE LIGHTING smell all around the
appliance area for gas. Be sure to smell next
to the floor because some gas is heavier than
air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not
use any phone in your building.
• Immediately call your gas supplier from
a neighborʼs phone. Follow the gas
supplierʼs instructions.
• If you cannot reach your gas supplier, call
the fire department.