background image

24

103280

IGNITOR

LIGHTING INSTRUCTIONS

Figure 30 - Control Knob and Ignitor Button Location

WARNING ICON

G 001

 WARNING

You must operate this fireplace with the fireplace screen in place.
Make sure fireplace screen is installed before running fireplace.

NOTICE

During initial operation of new fireplace, burning logs will give off
a paper-burning smell. Orange flame will also be present. Open
window to vent smell. Operate fireplace on HI position to burn off
odor. This will only last a few hours.

1. STOP! Read the safety information on above.
2. Make sure manual shutoff valve is fully open.

3. Turn control knob clockwise 

Clockwise

 to the OFF position.

Ignitor Button

Control Knob

OPERATING

FIREPLACE

Manually-Controlled

Models

A. This appliance has a pilot which must be lighted by hand. When lighting the pilot,

follow these instructions exactly.

B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell

next to the floor because some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas

supplier’s instructions.

• If you cannot reach your gas supplier, call the fire department.

C. Use only your hand to push in or turn the gas control knob. Never use tools. If the

knob will not push in or turn by hand, don’t try to repair it, call a qualified service
technician or gas supplier. Force or attempted repair may result in a fire or
explosion.

D. Do not use this appliance if any part has been under water. Immediately call a

qualified service technician to inspect the appliance and to replace any part of the
control system and any gas control which has been under water.

WARNING ICON

G 001

 WARNING

If you do not follow these instructions exactly, a fire or explosion may
result causing property damage, personal injury or loss of life.

FOR YOUR SAFETY READ BEFORE LIGHTING

4. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the

floor. If you smell gas, STOP! Follow “B” in the safety information above. If you
don’t smell gas, go to the next step.

5. Slightly depress and turn control knob counterclockwise 

C-clockwise

 to the PILOT

position. Press in control knob for five (5) seconds (see Figure 30, above).

Note:

 If running fireplace for first time, there will be air in gas line. You may

need to press in control knob for 30 seconds or longer. This will allow air to
bleed from the gas system.

Содержание VSGF28PTA

Страница 1: ...ice must be performed by a qualified installer service agency or the gas supplier WARNING Improperinstallation adjustment alteration service or maintenance can cause injury orpropertydamage Refertothis manual for correct installation and operational procedures For assistance or additional infor mation consult a qualified in staller service agency or the gas supplier WARNING This is an unvented gas...

Страница 2: ... gas The odor helps you detect a gas leak However the odor added to the gas can fade Gas may be present even though no odor exists Make certain you read and understand all Warnings Keep this manual for reference It is your guide to safe and proper operation of this fireplace Safety Information continues on next page Safety Information 2 Product Identification 4 Local Codes 5 Unpacking 5 Product Fe...

Страница 3: ...ur due to log curing and fireplace burning manufacturing residues 10 Do not allow fans to blow directly into the fireplace Avoid any drafts that alter burner flame patterns Ceiling fans can create drafts that alter burner flame patterns Altered burner patterns can cause sooting 11 Do not use a blower insert heat exchanger insert or other accessory not approved for use with this heater 12 This fire...

Страница 4: ...2 Fireplace Top Louver Assembly Firebox Hood Bottom Louver Assembly Screen Assembly Top Outer Casing Firebox Support Side Access Door Rear Access Door Left Front Branch Rear Log Base Assembly Front Burner Rear Burner Crossover Log Top Middle Log Bottom Middle Log Right Front Branch ...

Страница 5: ...ck up heat Safety Device This fireplace has a pilot with an Oxygen Depletion Sensor Shutoff System ODS The ODS pilot is a required feature for vent free room heaters The ODS system shuts off the fireplace if there is not enough fresh air Piezo Ignition System This fireplace has a piezo ignitor This system requires no matches batteries or other sources to light fireplace Blower Assembly This firepl...

Страница 6: ...92 Section 5 3 defines confined space as having an air volume of less than 50 cubic feet 127 cubic cm for each 1000 Btu Hr input rating of all appliances in the space cubic feet equals length x width x height of space Include adjoining rooms only if there are doorless passageways or ventilation grills between the rooms PROVIDING ADEQUATE VENTILATION The following is exerpts from National Fuel Gas ...

Страница 7: ...ter ___________________ Btu Hr Gas fireplace logs ___________________ Btu Hr Other gas appliances ___________________ Btu Hr Total ___________________ Btu Hr Example Gas water heater 40 000 Btu Hr Vent free fireplace 28 000 Btu Hr Total 68 000 Btu Hr Do not include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr t...

Страница 8: ... G 001 WARNING Rework worksheet adding the space of the adjoining unconfined space The combined spaces must have enough fresh air to supply all appliances in both spaces Figure 4 Ventilation Air from Outdoors Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts You must provide two perma nent openings one within 12 of the ceiling and one within 12 of the floor...

Страница 9: ...lace Installing fireplace next to vinyl or cloth wall coverings or operating fireplace where impurities in the air such as tobacco smoke exist may discolor walls IMPORTANT Vent free heaters add moisture to the air Although this is beneficial installing fireplace in rooms without enough ventilation air may cause mildew to form from too much moisture See Air for Combustion and Ventilation pages 6 th...

Страница 10: ...ide other end of adjusting plate shim in slot on mitered edge of side brass trim see Figure 5 6 While firmly holding edges of brass trim together tighten both set screws on the adjusting plate with slotted screwdriver 7 Repeat steps 1 through 6 for other side Side Brass Trim Top Brass Trim Slot Mitered Edge Slot Shim Set Screws Adjusting Plate Figure 5 Assembling Brass Trim Trim Hanging Screws Ass...

Страница 11: ...earth bases CONVENTIONAL FIREPLACE INSTALLATION Conventional installation of this fireplace involves installing fireplace along with the corner face or cabinet mantel with hearth base accessories against a wall in your home Follow the instructions below to install the fireplace in this manner Figure 7 Minimum Clearance to Wall and Ceiling QQQQQ QQQQQ QQQQQ QQQQQ QQQQQ 42 16 Face or Cabinet Mantel ...

Страница 12: ...lexible gas line to fireplace see Figure 8 Make sure to locate access hole so cabinet mantel will cover it when installed Note You can secure base to floor using wood screws Countersink screw heads and putty over Figure 8 Placing Hearth Base Accessory Against Wall 5 Route flexible gas line through access hole in hearth base 6 Center cabinet mantel on hearth base see Figure 9 Make sure mantel is fl...

Страница 13: ...ugh these holes and into hearth or floor 12 Check all gas connections for leaks See Checking Gas Connections page 18 Continued Figure 11 Inserting Fireplace Into Cabinet Mantel QQQQQ QQQQQ QQQ QQQ QQQ QQQ QQQ 1 Frame in rough opening Use dimensions shown in Figure 12 for the rough opening 35 1 2 17 3 4 33 Figure 12 Rough Opening for Installing in Wall BUILT IN FIREPLACE INSTALLATION Built in insta...

Страница 14: ...after the manual shutoff valve The flexible gas line must be the last item installed on the gas piping See Installing Gas Piping to Fireplace Location page 16 4 Carefully set fireplace in front of rough opening with back of fireplace inside wall opening 5 Attach flexible gas line to fireplace gas regulator See Connecting Fireplace to Gas Supply page 17 6 Route blower electrical cord through side o...

Страница 15: ...Needed Before installing fireplace make sure you have the items listed below piping check local codes sealant resistant to LP propane gas manual shutoff valve test gauge connection sediment trap tee joint pipe wrench approved flexible gas line with gas connector if allowed by local codes not provided NOTICE A qualified service person must connect fireplace to gas supply Follow all local codes An A...

Страница 16: ...G ICON G 001 CAUTION Use pipe joint sealant that is resistant to liquid petroleum LP gas Install sediment trap in supply line as shown in Figure 17 page 17 Locate sedi ment trap where it is within reach for cleaning Locate sediment trap where trapped matter is not likely to freeze A sediment trap traps moisture and contaminants This keeps them from going into fireplace gas controls If sediment tra...

Страница 17: ...pane LP gas not provided 1 Remove fireplace screen Remove two screws that hold fireplace screen in place for shipping These screws are located near top of screen Discard screws Lift fireplace screen up and pull out to remove 2 Remove access door from rear or side of fireplace See Product Identification page 4 for access door locations 3 Remove screws that attach log base assembly to fireplace see ...

Страница 18: ...orrect all leaks at once WARNING ICON G 001 WARNING Never use an open flame to check for a leak Apply a mixture of liquid soap and water to all joints Bubbles forming show a leak Correct all leaks at once Figure 19 Attaching Flexible Gas Lines Together 5 Apply pipe joint sealant lightly to male threads of gas connector attached to flexible gas line see Figure 18 Connect flexible gas line to flexib...

Страница 19: ...osition 4 Check all joints from manual shutoff valve to thermostat gas valve see Figure 21 Apply mixture of liquid soap and water to gas joints Bubbles forming show a leak 5 Correct all leaks at once 6 Light fireplace see Operating Fireplace pages 22 and 23 Thermostat con trolled models or pages 24 and 25 Manually controlled models Check all other internal joints for leaks 7 Turn off fireplace see...

Страница 20: ...te bar Note 18 model has only one front log 2 Rest bottom middle log 2 behind metal posts on front burner Make sure the grooves in the bottom of the log fit over the grate Bring the log forward next to the metal posts The pegs on the log must be on top see Figure 23 3 Slide the grooves in the back of the rear log 3 against the rear grate prongs Make sure the peg on the log is on top see Figure 24 ...

Страница 21: ...iddle log see Figure 26 Figure 26 Installing Crossover Log 5 Crossover Log 4 Hole Peg Cutout 5 Install fireplace screen by slipping notches of fireplace screen over screws on front of fireplace see Figure 27 Notches Screws for Mounting Screen Figure 27 Installing Fireplace Screen WARNING ICON G 001 WARNING You must operate this fireplace with the fireplace screen in place Make sure fireplace scree...

Страница 22: ...hone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service technician or gas supplier Force or attempted repair may result in a fire or explosion D Do not use this appliance if any p...

Страница 23: ... level The burners should light Set control knob to any heat level between HI and LO CAUTION Do not try to adjust heating levels by using the manual shutoff valve TO TURN OFF GAS TO APPLIANCE Shutting Off Fireplace Turn control knob clockwise Clockwise to the OFF position Shutting Off Burners Only pilot stays lit Turn control knob clockwise Clockwise to the PILOT position THERMOSTAT CONTROL OPERAT...

Страница 24: ...l your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service technician or gas supplier Force or attempted repair may result in a fire or explosi...

Страница 25: ...G Do not operate heater between locked positions WARNING ICON G 001 CAUTION Do not try to adjust heating levels by using the manual shutoff valve VARIABLE CONTROL OPERATION The variable control valve can be set to any heat setting and flame height desired by simply turning the control knob until that setting is attained Even the lowest setting provides realistic flames and glowing embers from two ...

Страница 26: ...rolled blowers have three settings ON OFF and AUTO In the ON position the blower will operate constantly In the OFF position the blower will not operate In the AUTO position the blower will start when the thermostat senses a sufficient increase in firebox temperature Note Your gas logs and thermostat blower will not turn on and off at the same time The fireplace may run for several minutes before ...

Страница 27: ...rner is normal NOTICE Do not mistake orange flames with yellow tipping Dirt or other fine particles are burned by fireplace causing brief patches of orange flame INSPECTING BURNERS Continued If front burner flame pattern is incorrect as shown in Figure 34 turn fireplace off see To Turn Off Gas to Appliance page 23 Thermostat controlled models or page 25 Manually controlled models see Troubleshooti...

Страница 28: ...ot WARNING ICON G 001 CAUTION You must keep control areas burners and circulating air pas sageways of fireplace clean Inspect these areas of fireplace before each use Have fireplace inspected yearly by a qualified service person Fireplace may need more frequent cleaning due to excessive lint from carpeting bedding material etc ODS PILOT AND BURNERS Use a vacuum cleaner or small soft bristled brush...

Страница 29: ...k system to reset Repeat ignition operation POSSIBLE CAUSE 1 Gas supply turned off or manual shutoff valve closed 2 Control knob not in PILOT position 3 Control knob not pressed in while in PILOT position 4 Air in gas lines when installed 5 ODS pilot is clogged 6 Gas regulator setting is not correct 1 Control knob not fully pressed in 2 Control knob not pressed in long enough 3 Manual shutoff valv...

Страница 30: ...clean burner s seeCleaningand Maintenance page 28 2 Replace gas regulator 1 Problem will stop after a few hours of operation 1 Turn control knob to LO position and let warm up for a minute 2 Operate burners until air is removed from line Have gas line checked by local propane gas company 3 Observe minimum installation clearances see page 11 4 Clean burners see Cleaning and Mainte nance page 28 or ...

Страница 31: ...ogged 1 Gas leak See Warn ing statement above 2 Control valve defective 1 Foreign matter be tween control valve and burner 2 Gas leak See Warn ing statement above 1 Not enough combus tion ventilation air OBSERVED PROBLEM Fireplace produces a clicking ticking noise just after burners are lit or shut off Fireplace produces unwanted odors Fireplace shuts off in use ODS operates Gas odor even when con...

Страница 32: ... your warranty cover age for parts replaced under warranty Parts Under Warranty Contact authorized dealers of this product If they can t supply original replace ment part s call DESA International s Technical Service Department at 1 800 DESA LOG 1 800 337 2564 When calling DESA International have ready your name your address model number of your fireplace how fireplace was malfunctioning type of g...

Страница 33: ...ack Green White On 110 115 V A C Blower Motor Blower Motor Black Off 1 2 3 Auto Red Fan Switch Off On Black Black Black Black Green White On 110 115 V A C Blower Motor Blower Motor Black Off 1 2 WIRING DIAGRAMS Figure 36 Blower Wiring Diagram for Manually Controlled Models Figure 37 Blower Wiring Diagram for Thermostat Controlled Models CAUTION Label all wires prior to disconnection when servicing...

Страница 34: ...2 for information You can also write to the address listed on the back page of this manual CABINET MANTEL GM100F Walnut Finished GM101U Unfinished Shown with optional base and laminate hearth and mantel trim accessories Dimensions WxHxD 56 3 4 x 48 3 4 x 20 5 8 FACE MANTEL GM400F Walnut Finished GM401U Unfinished Shown with optional slim base Dimensions WxHxD 56 3 4 x 48 3 4 x 7 HARDWOOD HEARTH BA...

Страница 35: ...Trim G3003J Jade Marble Laminate Hearth Base Trim G3002S Sandstone Marble Laminate Mantel Trim G3003S Sandstone Marble Laminate Hearth Base Trim G3002B Black Onyx Marble Laminate Trim G3003B Black Onyx Marble Laminate Hearth Base Trim Mantel trim for cabinet face or corner mantel Hearth base trim for hardwood hearth bases Hearth Base Trim Mantel Trim FIREBOX BRICK LINER G8000 Ceramic fiber firebox...

Страница 36: ...LUSTRATED PARTS BREAKDOWN Log Base Assembly Variable Manually Controlled Models VSGF28PV CSGF28PV 27 8 9 8 8 19 13 12 8 6 7 7 1 7 2 10 18 23 16 11 26 14 6 6 6 6 21 15 19 32 29 24 30 20 28 31 25 17 22 4 5 3 2 1L 1R ...

Страница 37: ...02 Rear Burner Assembly 1 12 102256 04BR Base Assembly 1 13 098271 06 Ignitor Cable 1 14 101924 01CB Firebox Bottom 1 15 098867 10 Gas Regulator 1 16 101004 01 Front Burner Injector 1 17 102445 01 Piezo Ignitor 1 18 101007 01 Crossover Tube 1 19 099387 05 Pilot Tube 1 20 101972 01 Valve and Piezo Bracket 1 21 M11084 38 Regulator Hex Screw 2 22 102668 01 Front Burner Tube 1 23 101008 01 Gasket 1 24...

Страница 38: ...80 ILLUSTRATED PARTS BREAKDOWN Log Base Assembly Thermostat Controlled Models VSGF28PTA CSGF28PTA 18 6 27 8 9 8 8 19 13 12 7 7 1 7 2 10 16 11 26 14 29 6 6 6 6 22 25 23 19 24 13 7 2 20 15 28 21 17 4 5 3 2 1L 1R ...

Страница 39: ... Pilot Bracket 1 10 101330 02 Front Burner Assembly 1 11 100999 02 Rear Burner Assembly 1 12 101392 02BR Base Assembly 1 13 098271 06 Ignitor Cable 1 14 101924 01CB Firebox Bottom 1 15 098867 10 Gas Regulator 1 16 101004 04 Front Burner Injector 1 17 102845 01 Inlet Tube 1 18 101382 01 Thermovalve Bracket 1 19 099387 03 Pilot Tube 1 20 102846 01 Burner Tube 1 21 097809 02 Adapter 1 22 099211 01 Sc...

Страница 40: ...40 103280 ILLUSTRATED PARTS BREAKDOWN Fireplace 1 2 3 4 5 6 12 13 6 18 29 19 21 26 23 7 24 27 20 28 16 16 16 16 7 17 10 11 14 30 16 16 15 8 9 16 16 22 25 25 25 VSGF28PV CSGF28PV VSGF28PTA CSGF28PTA ...

Страница 41: ...Firebox Wrapper Manual Models 1 15 101614 01 Limit Switch thermal disk Assy 1 16 M11084 26 Hex Screw 10 76 17 098304 03 Phillips Pan Head Screw 8 4 18 101727 01 Screen Assembly 1 19 101575 01 Motor Housing Assembly 1 20 099998 01 Fan Switch Thermostat Models 1 101886 01 Fan Switch Manual Models 1 21 101379 01 Fan 2 22 101408 01 Motor 2 23 101348 01 Firebox Support 2 24 101347 01CB Outer Base 1 25 ...

Страница 42: ...42 103280 NOTES ...

Страница 43: ...43 103280 NOTES ...

Страница 44: ...nd all such other costs related to repairing a defective heater will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHE PRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO THREE 3 Y...

Отзывы: