manualshive.com logo in svg
background image

Save this manual for future reference.

For more information, visit www.desatech.com

WARNING: If the information in this manual is not fol-
lowed exactly, a fire or explosion may result causing 
property damage, personal injury or loss of life.

—  Do  not  store  or  use  gasoline  or  other  flammable 

vapors and liquids in the vicinity of this or any other 

appliance.

—  WHAT TO DO IF YOU SMELL GAS

•  Do not try to light any appliance.
•  Do not touch any electrical switch; do not use any 

phone in your building.

•  Immediately call your gas supplier from a neighbor’s 

phone. Follow the gas supplier’s instructions.

•  If you cannot reach your gas supplier, call the fire 

department.

—  Installation and service must be performed by a quali-

fied installer, service agency or the gas supplier.

UNVENTED (VENT-FREE) SOLAR FUSION GAS HEATER

SAFETY INFORMATION AND INSTALLATION MANUAL

RESIDENTIAL MODELS

SF20NT, SF20PT, 

LSF20NT, LSF20PT, 

VSF20NT, VSF20PT, 

SF30NT, SF30PT, 

LSF30NT, LSF30PT, 
VSF30NT, VSF30PT

GARAGE MODELS

LSFG20NT, LSFG20PT, 

REM20NT, REM20PT, 

SFG20NT, SFG20PT, 
SPC20NT, SPC20PT, 

VSFG20NT, VSFG20PT

Содержание VSF20NT

Страница 1: ...touch any electrical switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call...

Страница 2: ...late This appliance is not convert ible for use with other gases Aftermarket Completion of sale not for purpose of resale from the manufacturer State of Massachusetts The installation must be made by...

Страница 3: ...s heater WARNING Any change to this heater or its controls can be dangerous WARNING Do not use a blower insert heat exchanger insertorotheraccessorynotap proved for use with this heater Due to high te...

Страница 4: ...white powder residue within burner box or on adjacent walls or furniture 14 Provide adequate clearances around air openings LOCAL CODES Installanduseheaterwithcare Followalllocalcodes In the absence...

Страница 5: ...must provide additional fresh air Unusually tight construction is de ned as construction where a walls and ceilings exposed to the out side atmosphere have a continuous water vapor retarder with a rat...

Страница 6: ...axi mum Btu Hr the space can support You must provide additional fresh air Your options are as follows A Rework worksheet adding the space of an adjoin ingroom Iftheextraspaceprovidesanuncon ned space...

Страница 7: ...pri mary heat source If you have a centralheatingsystem youmay run system s circulating blower whileusingheater Thiswillhelp circulatetheheatthroughoutthe house In the event of a power outage you can...

Страница 8: ...s experienced a dehumidi er may be used to help lower the water vapor content in the air INSTALLATION Continued For convenience and ef ciency install heater where there is easy access for operation in...

Страница 9: ...l Attaching To Wall Anchor Method For attaching heater to hollow walls wall areas be tween studs or solid walls concrete or masonry 1 Drill holes at marked locations using 5 16 drill bit For solid wal...

Страница 10: ...d in certain areas Check your local codes Use pipe of large enough diameter to allow proper gas volume to heater If pipe is too small undue loss of volume will occur Typical Inlet Pipe Diameters 20 00...

Страница 11: ...ct ing to Gas Supply page 10 PRESSURE TESTING GAS SUPPLY PIPING SYSTEM Test Pressures In Excess Of 1 2 PSIG 3 5 kPa 1 Disconnect appliance with its appliance main gas valve control valve and equipment...

Страница 12: ...nt Shutoff Valve OPERATING HEATER FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not fol low these instructions exactly a re or explosion may result causing property damage per sonal injury or...

Страница 13: ...because some gas is heavier than air and will settle on the oor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electric switch do not use any phone in your building Imm...

Страница 14: ...PROCEDURE 1 Remove front panel see Figure 10 page 9 2 Follow steps 1 through 7 under Lighting Instructions page 13 3 With control knob pressed in strike match Hold match to pilot until pilot lights 4...

Страница 15: ...we recommend using compressed air no greater than 30 PSI Your local computer store hardware store or home center may carry compressed air in a can You can use a vacuum cleaner in the blow position If...

Страница 16: ...ropane LP gas 5 ODS pilot is clogged 6 Gas regulator setting is not correct 7 Thermostat control knob is not in pilot position REMEDY 1 Replace pilot assembly 2 Replace pilot assembly 3 Reconnect igni...

Страница 17: ...AfterODS pilotlights keepcon trol knob pressed in 30 seconds 3 Fully open equipment shutoff valve 4 Hand tighten until snug then tighten 1 4 turn more 5 A Contact local natural or propane LP gas compa...

Страница 18: ...ller inspect burner 1 Problem will stop after a few hours of operation 1 Thisiscommonwithmostheat ers Ifnoiseisexcessive contact quali ed service person 1 Turn control knob to the low est position and...

Страница 19: ...l supply tank 3 Locate and correct all leaks see Checking Gas Connec tions page 11 1 Locate and correct all leaks see Checking Gas Connec tions page 11 2 Replace control valve 1 Take apart gas tubing...

Страница 20: ...tronic Ignition Pressure Regulator Setting 3 W C Inlet Gas Pressure in of water Maximum 10 5 Minimum 4 REM20PT SF20PT SFG20PT SPC20PT AND VSFG20PT Propane LP Gas 10 500 20 000 Btu Hr Variable Piezo Ig...

Страница 21: ...ginal replacement part s either contact your nearest Parts Central or call DESA Heating Products at 1 866 672 6040 for referral information When calling DESA Heating Products have ready model number o...

Страница 22: ...S SF20NT SF20PT LSF20NT LSF20PT VSF20NT VSF20PT SF30NT SF30PT LSF30NT LSF30PT VSF30NT VSF30PT GARAGE MODELS LSFG20NT LSFG20PT REM20NT REM20PT SFG20NT SFG20PT SPC20NT SPC20PT VSFG20NT VSFG20PT AA Batte...

Страница 23: ...103446 03 Burner 1 103447 07 Burner 1 15 110803 01 ODS Pilot 1 110803 02 ODS Pilot 1 16 098271 11 Ignitor Cable 1 098271 09 Ignitor Cable 1 17 103845 05 Injector 1 103845 06 Injector 1 103845 07 Inje...

Страница 24: ...ough authorized dealers of this product and or DESAHeating Products who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty The heater...

Страница 25: ...uptor el ctrico no use nin g n tel fono en el edi cio Llame inmediatamente a su proveedor de gas desde el tel fono de alg n vecino Siga las instrucciones del proveedor de gas Si no puede localizar al...

Страница 26: ...cadeclasi caci n Esteaparato no se puede convertir para que utilice otro tipo de gas Mercado de posventa venta completada por parte del fabricante sin nes de reventa TABLA DE CONTENIDO Informaci n de...

Страница 27: ...ambio a este calentador o a los controles puede ser peligroso ADVERTENCIA no utilice un aditamento de ventilador o de in tercambio de calor ni ning n otro accesorio que no est aprobado para usarse con...

Страница 28: ...s paredes o los muebles adyacentes 14 Procure que se cumplan las distancias m nimas alrededor de las aberturas de aire C DIGOS LOCALES Instale y use el calentador cuidadosamente Siga todos los c digos...

Страница 29: ...e aire fresco para la combusti n y la ventilaci n Sin embargo en losedi ciosquetienenunaconstrucci ninusualmente sellada tiene que proporcionar aire fresco adicional Una construcci n inusualmente sell...

Страница 30: ...pacio con nado por que la cantidad real de BTU h que se utiliza es mayor AIRE PARA COMBUSTI N Y VENTILACI N Continuaci n que la cantidad m xima de BTU h que el espacio puede admitir Se tiene que propo...

Страница 31: ...iones en el sitio no est n permitidas ART CULOS DE INSTALACI N Antes de instalar el calentador aseg rese de tener los art culos que se indican a continuaci n Para propano o gas LP un regulador externo...

Страница 32: ...aden humedad al aire Aunque esto es ben co la instalaci ndelcalentadorenhabitacionessinsu ciente aire de ventilaci n puede ocasionar la formaci n de mohodebidoalexcesodehumedad ConsulteAirepara combus...

Страница 33: ...or en los tornillos de montaje 1 Localice las dos ranuras verticales superiores en los paneles del extremo posterior del calentador 2 Coloque el calentador en los tornillos de montaje Figura 7 C mo do...

Страница 34: ...acceso a ella para limpieza Sit e la trampa de sedimentos donde sea poco probable que los materiales atrapa dos en ella se congelen La trampa de sedimentos atrapa humedad y contaminantes Esto evita qu...

Страница 35: ...ER A DE SUMINISTRO DE GAS Pruebas de presiones mayores a 1 2 PSI 3 5 kPa 1 Desconecte el aparato junto con la v lvula principal de gas del aparato v lvula de control y la v lvula de cierre del equipo...

Страница 36: ...ermostato V lvula de cierre del equipo V lvula de gas del termostato V lvula de cierre del equipo FUNCIONAMIENTO DEL CALENTADOR PARA SU SEGURIDAD LEA ESTO ANTES DE ENCENDERLO ADVERTENCIA si no sigue e...

Страница 37: ...de gas desde el tel fono de alg n vecino Siga las instrucciones del proveedor de gas Si no puede localizar al proveedor de gas llame al departamento de bomberos C Utilice nicamente la mano para presio...

Страница 38: ...DIDO MANUAL 1 Desmonte el panel anterior consulte la gura 10 en la p gina 9 2 Realice los pasos 1 a 7 de las Instrucciones de encendido p gina 13 3 Con la perilla de control presionada encienda un f s...

Страница 39: ...del quemador 4 Nunca inserte objetos en el tubo del piloto Limpietambi nelconjuntodelpiloto Unapuntaama rilla en la llama del piloto indica la presencia de polvo y suciedad en el conjunto del mismo Ha...

Страница 40: ...tapado 6 La posici n del regulador de gas no es la correcta 7 Laperilladecontroldeltermostato no est en la posici n de piloto REMEDIO 1 Reemplace el conjunto del piloto 2 Reemplace el conjunto del pil...

Страница 41: ...durante 30 segundos 3 Abra la v lvula de cierre del equipo totalmente 4 Apriete con la mano hasta que sienta que topa luego apriete 1 4 de vuelta m s 5 A Comun quese con la com pa a local de gas natur...

Страница 42: ...blema desaparecer despu s de algunas horas de funcionamiento 1 Estoescom nenlamayor ade los calentadores Si el ruido es excesivo comun queseconuna persona de servicio capacitada 1 Girelaperilladecontr...

Страница 43: ...tro 3 Localice y repare todas las fugas consulteRevisi ndelasconexio nes de gas en la p gina 11 1 Localice y repare todas las fugas consulteRevisi ndelasconexio nes de gas en la p gina 11 2 Reemplace...

Страница 44: ...n del regulador de presi n 3 de c a Presi n del gas de entrada pulg de agua M ximo 10 5 M nimo 4 REM20PT SF20PT SFG20PT SPC20PT Y VSFG20PT Propano o gas LP 10 500 20 000 Btu h variable Encendido piezo...

Страница 45: ...za dos de este producto Si ellos no pueden suministrar piezas de repuesto originales comun quese con la central de piezas m s cercana o llame a DESA Heating Products al 1 866 672 6040 para obtener inf...

Страница 46: ...SF20PT VSF20NT VSF20PT SF30NT SF30PT LSF30NT LSF30PT VSF30NT VSF30PT MODELOS PARA COCHERA LSFG20NT LSFG20PT REM20NT REM20PT SFG20NT SFG20PT SPC20NT SPC20PT VSFG20NT VSFG20PT AA Battery Positive UP AAA...

Страница 47: ...Quemador 1 15 110803 01 Piloto con ODS 1 110803 02 Piloto con ODS 1 16 098271 11 Cable del encendedor 1 098271 09 Cable del encendedor 1 17 103845 05 Inyector 1 103845 06 Inyector 1 103845 07 Inyector...

Страница 48: ...res autorizados de este producto y de DESAHeating Products quienes proporcionar n las piezas de repuesto originales de f brica Si no se utilizan piezas de repuesto originales de f brica esta garant a...

Отзывы: