Desa VS36 Series Скачать руководство пользователя страница 2

                                                                                                   - 1 

-                                                             For more information, visit www.desatech.com

 

     

CONTENTS 

 
 
 
1. 

INTRODUCTION    ------------------------------------------------------------- 

 PG. 

 
 
2. 

SELECTING 

LOCATION   ------------------------------------------------------------- 

 PG. 

 
 
3. 

MINIMUM 

CLEARANCES 

  ------------------------------------------------------------- 

 PG. 

 
 
4. 

FRAMING 

AND 

INSTALLING 

  ------------------------------------------------------------- 

 PG. 

 
 
5. 

 

HEARTH 

EXTENTION 

   ------------------------------------------------------------- 

 PG. 

 
 
6. 

OUTSIDE AIR KIT INSTALLATION 

 

-------------------------------------------------------------   

PG. 3 

 
 
7. 

CHIMNEY PIPE AND OFFSET INSTALLATION -------------------------------------------------------------   

PG. 4-5 

 
 
8. 

FIRESTOP SPACERS           

 

 

-------------------------------------------------------------   

PG. 5 

 
 
9. 

FLASHING AND TERMINATION 

 

-------------------------------------------------------------   

PG. 6-7 

 
 
10. 

FINISHING 

YOUR 

FIREPLACE 

  ------------------------------------------------------------- 

 PG. 

 
 
11. 

MANTELS 

    ------------------------------------------------------------- 

 PG. 

 
 
12. 

GLASS 

DOORS 

    ------------------------------------------------------------- 

 PG. 

 
 
13. 

GAS 

LINE 

INSTALLATIONS 

  ------------------------------------------------------------- 

 PG. 

 
 
14. 

DAMPER 

OPERATION 

   ------------------------------------------------------------- 

 PG. 

10 

 

 
 
15.  

TECHNICAL SERVICE 

   ------------------------------------------------------------- 

 PG. 

10 

 
 
16. 

ILLUSTRATED PARTS                                

-------------------------------------------------------------             PG.11-11a 

 
 
17. 

REPLACEMENT AND TECHNICAL PARTS 

-------------------------------------------------------------                PG.12 

 

Содержание VS36 Series

Страница 1: ...RGA 2 72 standards or for use with a vent free gas log heater approved to ANS Z21 11 2 standard A DESA hood must be installed when using a vent free gas log heater see Accessories p 12 WARNING Always...

Страница 2: ...ION PG 3 6 OUTSIDE AIR KIT INSTALLATION PG 3 7 CHIMNEY PIPE AND OFFSET INSTALLATION PG 4 5 8 FIRESTOP SPACERS PG 5 9 FLASHING AND TERMINATION PG 6 7 10 FINISHING YOUR FIREPLACE PG 7 11 MANTELS PG 8 12...

Страница 3: ...AL INSTALLATION The minimum height of the chimney measured from the base of the fireplace to the flue gas outlet of the termination is 14 5 feet for straight flue or a flue with one elbow set The maxi...

Страница 4: ...raming through flanges located on the sides of the fireplace HEARTH EXTENSION A hearth extension projecting a minimum of 16 in front of and a minimum of 8 beyond each side of the fireplace opening is...

Страница 5: ...ependently as the chimney is installed For Canada use chimney parts designated HT When connecting chimney directly to the fireplace the inner flue pipe section must be installed first with the lanced...

Страница 6: ...gure 9 They also provide complete separation from one floor space to another or attic space as required by most codes When the double wall pipe passes through a framed opening into an attic space the...

Страница 7: ...ASHING INSTALLATION V6F 8DM or V12F 8DM Determine the flashing to be used with the roof opening chart Slide flashing over pipe until base is flat against roof Replace as many shingles as needed to cov...

Страница 8: ...prevent smoke spillage from one termination to another We suggest that terminations be separated at least 24 inches center to center and stacked at vertical height difference of 18 inches see figure 1...

Страница 9: ...combustion air gate is not completely open The following tips should be followed to assure that both the fireplace and the glass door retain their beauty and function properly Both the flue damper an...

Страница 10: ...raming to provide rigidity for threaded end STEP 4 Repack insulation around gas line and into sleeve opening Seal any gaps between gas line and refractory knockout hole with refractory cement or comme...

Страница 11: ...ure 21 Pulling the handle out will free the outside air door to open Pushing the handle in will lock the door close FOR FURTHER OPERATING GUIDELINES INSTRUCTIONS AND WARRANTY INFORMATION PLEASE REFER...

Страница 12: ...691 01 106691 01 106691 01 18 FIREBOX TOP ASSEMBLY 1 106694 01 106694 01 106694 01 106694 01 106694 01 106694 01 19 AIR KIT DOOR ASSEMBLY 1 106703 01 106703 01 106703 01 106703 01 106703 01 106703 01...

Страница 13: ...11a For more information visit www desatech com ILLUSTRATED PARTS...

Страница 14: ...12 For more information visit www desatech com REPLACEMENT PARTS ACCESSORY PARTS SEE PARTS LIST ON PAGE 11 FOR PART NUMBERS...

Отзывы: