background image

13

103449

OWNER’S MANUAL

Top Middle Log (#4)

Figure 20 - Installing Crossover Log (#5)

Crossover
Log (#4)

Hole

Peg

Cutout

INSTALLATION

Continued

Figure 19 - Installing Top Log (#4)

Hole

Peg

Peg

Bottom
Middle Log

Hole

INSTALLING LOGS

Figure 16- Installing Front Logs
(#1L and #1R)

Figure 17 - Installing Bottom Middle
Log (#2)

Figure 18 - Installing Rear Log (#3)

 WARNING: Failure to position

the parts in accordance with these
diagrams or failure to use only
parts specifically approved with
this heater may result in property
damage or personal injury.

Each log is marked with a number. These
numbers will help you identify the log when
installing. It is very important to install these
logs exactly as instructed. Do not modify
logs. Only use logs supplied with heater.

1.

Place front logs (#1L and #1R) on top
of the grate. Make sure the notches in
the bottom of the logs fit over the grate
prongs (see Figure 16). Push back of
logs flush with metal grate bar. 

Note:

18" model has only one front log.

2.

Rest bottom middle log (#2) behind
metal posts on front burner. Make sure
the grooves in the bottom of the log fit
over the grate. Bring the log forward
next to the metal posts. The pegs on
the log must be on top (see Figure 17).

3.

Slide the grooves in the back of the rear
log (#3) against the rear grate prongs.
Make sure the peg on the log is on top
(see Figure 18).

4.

Place the top middle log (#4) on the
bottom middle log (#2). Make sure the
pegs of the bottom middle log fit se-
curely in the holes of the top middle
log (see Figure 19).

5.

Place the crossover log (#5) on the back
log and the top middle log. Make sure
the peg on the rear log is in the hole in
the bottom of the crossover log. The
crossover log should fit in the cutout
of the top middle log (see Figure 20).

Bottom Middle
Log (#2)

Metal Post

Metal Post

Peg

Groove

Groove

Grate

Grate
Prongs

Metal Grate Bar

Front Log (#1L)

Notch

Front Log
(#1R)

Rear
Log (#3)

Peg

Grate
Prong

Grate
Prong

Rear
Burner

Groove
in Back
of Log

Groove
in Back
of Log

Содержание VS18NR

Страница 1: ...roperty damage Refer to this manual for cor rect installation and operational proce dures For assistance or additional in formation consult a qualified installer service agency or the gas supplier WAR...

Страница 2: ...with a fire placescreeninplace Makesurefireplace screen is closed before running heater 8 This log heater is designed to be smoke less If logs ever appear to smoke turn offheaterandcallaqualifiedservi...

Страница 3: ...ed to ANS Z21 11 2 standard for unvented heaters State and local codes in some areas prohibit the use of vent free heaters This heater may also be operated as a vented decorative ANS Z21 60 product by...

Страница 4: ...rating of one perm 6x10 11 kg per pa sec m2 or less with open ings gasketed or sealed and b weather stripping has been added on openable windows and doors and c caulking or sealants are applied to ar...

Страница 5: ...ances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used _________________ Btu Hr max...

Страница 6: ...d Crawl Space To Crawl Space To Attic Or Remove Door into Adjoining Room Option 3 Ventilation Grills Into Adjoining Room Option 2 Ventilation Grills Into Adjoining Room Option 1 12 12 Figure 2 Ventila...

Страница 7: ...l codes INSTALLATION CHECK GAS TYPE Use only natural gas If your gas supply is not natural gas do not install heater Call dealer where you bought heater for proper type heater INSTALLATION AND CLEARAN...

Страница 8: ...ntel If not using a mantel follow the information below You must have noncombustible material s above the fireplace opening Noncombus tible materials such as slate marble tile etc must be at least 1 2...

Страница 9: ...pening Underside of Mantel Shelf Mantel Shelf 12 A 20 241 2 271 2 30 All minimum distances are in inches 2 1 2 6 8 10 Minimum Noncombustible Material 8 Min 12 15 18 All minimum distances are in inches...

Страница 10: ...rsarelevel Ifheaterisnotlevel heaterwill not work properly Area of Various Standard Round Flues Diameter ins Area sq ins 5 20 sq inches 6 29 sq inches 7 39 sq inches 8 51 sq inches INSTALLING DAMPER C...

Страница 11: ...ed Purchase the optional A G A design certified manual shutoff valve from your dealer See Accessories page 23 Minimum inlet pressure for purpose of input adjustment Figure 13 Gas Connection Tee Joint...

Страница 12: ...ts individual manual shutoff valve from gas supply piping system Pressures in excess of 1 2 psig will damage heater regulator 2 Cap off open end of gas pipe where manual shutoff valve was connected 3...

Страница 13: ...ure 16 Push back of logs flush with metal grate bar Note 18 model has only one front log 2 Rest bottom middle log 2 behind metal posts on front burner Make sure the grooves in the bottom of the log fi...

Страница 14: ...re to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electric switch do not us...

Страница 15: ...em etc For wall thermostat operation follow in struction supplied with thermostat acces sory GWMT1 For wall switch operation followinstructionssuppliedwithGWMS2 OPTIONAL REMOTE OPERATION NOTICE You mu...

Страница 16: ...Off with the Hand Held Remote Unit Figure 24 Thermostat Hand Held Remote Control Unit Selections GHRCT only The log heater will automatically cycle between pilot and the heat setting that has been se...

Страница 17: ...e pattern Theincorrectpilotflameisnottouch ing the thermocouple This will cause the thermocouple to cool When the thermo couple cools the heater will shut down If pilot flame pattern is incorrect as s...

Страница 18: ...ware store or home center may carry com pressed air in a can You can use a vacuum cleaner in the blow position If using com pressed air in a can please follow the direc tions on the can If you don t f...

Страница 19: ...D PROBLEM When ignitor button is pressed there is no spark at ODS pilot When ignitor button is pressed there is spark at ODS pilot but no ignition ODS pilot lights but flame goes out when control knob...

Страница 20: ...en using furniture polish wax carpet cleaners or similar products 1 Replace 9 volt batteries in receiver and remote control OBSERVED PROBLEM One or both burners do not light after ODS pilot is lit Del...

Страница 21: ...SIBLE CAUSE 1 Metal expanding while heating or con tracting while cooling 1 Heater burning vapors from paint hair spray glues cleaners chemicals new carpet etc See IMPORTANT state ment above 2 Low fue...

Страница 22: ...r TECHNICAL SERVICE You may have further questions about in stallation operation or troubleshooting If so contact DESA International s Technical Service Department at 1 800 DESA LOG 1 800 337 2564 You...

Страница 23: ...LL MOUNT ON OFF SWITCH GWMS2 Not Shown For all models Allows the gas log heater to be turned on and off with a wall switch WALL MOUNT THERMOSTAT SWITCH GWMS1 Not Shown For all models The desired comfo...

Страница 24: ...URAL GAS LOG HEATER DESA INTERNATIONAL ILLUSTRATED PARTS BREAKDOWN VARIABLE CONTROL CFS18NR VS18NR VS24NR VS30NR 8 9 10 11 8 8 12 13 23 14 26 27 6 6 16 19 31 21 22 29 30 17 24 20 15 28 18 10 1 10 2 6...

Страница 25: ...271 03 Ignitor Cable 1 14 102445 01 102445 01 102445 01 Piezo Ignitor 1 15 103588 01 103588 01 103588 01 Heat Shield 1 16 103782 01 103782 01 103782 01 Valve Bracket 1 17 M12461 26 M12461 26 M12461 26...

Страница 26: ...such other costs related to repairing a defective heater will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EX...