4
trouBlesHootING
Continued
OBSERVED PROBLEM
Dark residue on logs or inside
of fireplace
POSSIBLE CAUSE
1..Improper.log.placement
2. Air holes at burner inlet
blocked
3. B u r n e r f l a m e h o l e s
blocked
4. Improper venting or exces
-
sive blockage
5. Excessive amounts of
embers and pan material
REMEDY
1. Properly locate logs
2. Clean out air holes at burn
-
er inlets. Periodically repeat
as needed
3..Remove. blockage. or. re-
place.burner
4. Have the vent system in
-
spected, including the ter
-
mination.cap..Remove.any.
restrictions or obstruction
5. Clear excess embers until
a. minimum. gap. of. 1/".
remains under the grate