TERMINATION CAP

AIR SUPPLY INLET

GAS METER

RESTRICTED AREA
(TERMINATION PROHIBITED)

A  =  clearance above grade, veranda, porch, deck, or
    balcony [*12" (30.5 cm) minimum]
B  =  clearance to window or door that may be opened 
    [6" (15 cm) min. for 10,000 Btu or less; 9" (23 cm) in US
    if between 10,000 and 50,000, 12" (30 cm) in Canada 
    if between 10,000 and 100,000; 12" (30 cm) in US if 
    greater than 50,000, 36" (91 cm) in Canada if greater 
    than 100,000]
C  =  clearance to permanently closed window
    [minimum 12" (30.5 cm) recommended to prevent
    condensation on window]
D  =  vertical clearance to ventilated soffit located above the
    terminal within a horizontal distance of 24" (61 cm) from
    the center-line of the terminal [18" (45.7 cm) minimum]
E  =  clearance to unventilated soffit [12" (30.5 cm) minimum]
F  =  clearance to outside corner (see below)
G  =  clearance to inside corner (see below)
H  =  *not to be installed above a meter/regulator assembly
    within 36" (91.4 cm) horizontally from the center line
    of the regulator

I  =  clearance to service regulator vent outlet [*72" (182.9 cm)
    minimum]
J  =  clearance to non-mechanical air supply inlet to building
    or the combustion air inlet to any other fireplace
    [6" (15 cm) min. for 10,000 Btu or less; 9" (23 cm) in US
    if between 10,000 and 50,000, 12" (30 cm) in Canada 
    if between 10,000 and 100,000; 12" (30 cm) in US if 
    greater than 50,000, 36" (91 cm) in Canada if greater 
    than 100,000]
K  =  clearance to a mechanical air supply inlet [*In Canada, 
    6 ft. (1.83m) minimum; In US 3 ft. (91 cm) above if within
    10 ft. (3 m) horizontally]
L  =  † clearance above paved side-walk or a paved driveway
    located on public property [*84" (213.3 cm) minimum]
M  =  clearance under veranda, porch, deck
    [*12" (30.5 cm) minimum ‡]
N  =  clearance above a roof shall extend a minimum of
    24" (61 cm) above the highest point when it passes
    through the roof surface and any other obstruction within
    a horizontal distance of 18" (45.7 cm) 

†  vent shall not terminate directly above a side-walk or paved driveway which is located between two
 

single family dwellings and serves both dwellings*

‡  only permitted if veranda, porch, deck or balconey is fully open on a minimum of 2 sides beneath the floor*
*  as specified in CAN/CSA B149 (.1 or .2) Installation Codes (1991) for Canada and U.S.A. 

Note: Local codes or regulations may require different clearances

A = 6" (15.2 cm)

Inside Corner

V

B

E

V

B = 6" (15.2 cm)

C = Maximum depth of 48" (121.9 cm)

 

for recessed location

D = Minimum width for back wall of 

 

recessed location -

 

Combustible - 38" (965 mm)

 

Noncombustible - 24" (61 cm)

E =  Clearance from corner in 

 

recessed location-

 

Combustible - 6" (15.2 cm)

 

Noncombustible - 2" (5.1 cm)

Outside Corner

Recessed Location

G

H

G = 12" (30.5 cm) minimum clearance

Balcony with No Side Wall

V

J

Combustible & 

Noncombustible

H = 24" (61 cm)

J = 20" (50.8 cm)

Balcony with Perpendicular Side Wall

C

D

C

Termination Clearances for Buildings with Combustible and Noncombustible Exteriors

Openable

Figure 7 - Minimum Clearances for Termination Cap

LOCATION OF TERMINATION CAP

Содержание VKC36N Series

Страница 1: ...or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any ph...

Страница 2: ...tive harm IMPORTANT Read this owner s manualcarefullyandcompletely before trying to assemble op erate or service this log set Improper use of this log set can cause serious injury or death from burns...

Страница 3: ...cessory not approved for use with this fire place WARNING This appliance is only for use with the type of gasindicatedontheratingplate Thisapplianceisnotconvertible for use with other gases unless a c...

Страница 4: ...and pilot light before cleaning fireplace 6 Have venting system inspected annually by a qualified service person If needed have venting system cleaned or repaired See Cleaning and Maintenance page 31...

Страница 5: ...nstructions very carefully for either vertical or horizontal applications This fireplace may be installed in any room of your house provided all local codes and these installation instructions are fol...

Страница 6: ...ntal blockage of venting system When using snow blowers do not direct snow towards vent termination area For horizontal installations above 2 000 feet it is recommended that a 12 extension pipe be add...

Страница 7: ...tel from Top of Louver Opening 1 14 35 6 cm A 16 40 6 cm 2 12 30 5 cm B 14 35 6 cm 3 10 25 4 cm C 12 30 5 cm 4 8 20 3 cm D 10 25 4 cm 5 6 15 2 cm E 8 20 3 cm 6 4 10 1 cm F 6 15 2 cm 7 2 5 1 cm G 4 10...

Страница 8: ...US if greater than 50 000 36 91 cm in Canada if greater than 100 000 K clearance to a mechanical air supply inlet In Canada 6 ft 1 83m minimum In US 3 ft 91 cm above if within 10 ft 3 m horizontally L...

Страница 9: ...ate on the out side of the structure and can not be attached to a chimney or flue system serving a separate solid fuel or gas burning appliance Adirect vent appliance must have its own venting system...

Страница 10: ...adjacent pipes Push pipe sections together and twist one section clockwise approximately one quarter turn until sections are fully locked see Figure 8 Note Horizontal runs of vent must be supported e...

Страница 11: ...d screws provided see Figure 11 Siding standoff must sit flush against exterior fascia material 7 Connecting Vent Cap with Horizontal Vent Pipe Slide wall firestop over vent pipe before connecting hor...

Страница 12: ...ired NOTICE Donotsealtermination cap to vent pipe Cap must be removable for vent inspection and maintenance WARNING Never run vent downward as this may cause excessive temperatures which could cause a...

Страница 13: ...commended Applications Installations requiring a vertical rise on building exterior Any installation using snorkel termination to achieve one foot above ground Snorkel terminations are available for i...

Страница 14: ...or a horizontal system using two 90 elbows Figure 18 Horizontal Termination Configuration for Venting Using Two 90 Elbows with Termination at 90 with Fireplace 45 Elbow Venting with Two 90 Elbows Vert...

Страница 15: ...f area above ceiling is an insulated ceiling or an attic nail firestop from top side This prevents loose insulation from falling into required clear ance space If area above ceiling is a living space...

Страница 16: ...ertical Venting Configuration Using One 90 Elbow Vertical Round High Wind Termination Shown 45 Elbow Note Install restrictor into inner collar of fireplace as shown similar factors may cause poor draf...

Страница 17: ...ested and approved for elevations from 0 2000 feet USA and elevations from 0 4500 feet Canada Fireplaces for High Altitude models ending in HA are for installation above 4000 feet only These fireplace...

Страница 18: ...r Roof Flashing 0 12 6 12 26 Screws VKC 58 Corner Vent Kit Galvanized Includes 45 Elbow 7 12 Adjustable Pipe Wall Firestop Horizontal Termination 6 Pipe 90 Elbow 18 Screws HHTK 58 High Wind Round Hori...

Страница 19: ...upward Blower will fit inside back opening and be held in position against back wall by magnets see Figure 26 4 Be certain that all wire terminals are securely attached to terminals on blower motor a...

Страница 20: ...wer cord outer insulation sleeve may have to be stripped slightly to allow enough wire length to reach and make all connec tions DO NOT trim excessive length away Enable just enough to make all connec...

Страница 21: ...Fan Switch N O Green White On 110 115 V A C Blower Motor Black Off 1 2 Black Installing Gas Piping to Fireplace Location WARNING A qualified service person must connect fireplace to gas supply Follow...

Страница 22: ...igure 32 Locate sediment trap drip leg where it is within reach for cleaning Install in piping sys tem between fuel supply and fireplace Locate sediment trap drip leg where trapped matter is not likel...

Страница 23: ...opening main gas valve located on or near gas meter for natural gas fireplace or using compressed air 4 Check all joints of gas supply piping sys tem Apply noncorrosive leak detection fluid to all joi...

Страница 24: ...not connected as shown switch will not work 2 Route 25 ft wire through openings pro vided on sides of burner system to a con venient location to mount your switch 3 Connect one bare wire end to each t...

Страница 25: ...moving glass door or louvers Removing Louver Panels Remove top and bottom louver panels by simultaneously pulling both top end spring latches towards center of appliance until they are disengaged from...

Страница 26: ...ilot ports with embers It is not necessary to use all of the ember material provided 2 Pour lava rock onto plenum but not onto flat burner It is not necessary to use all of the lava rock provided NOTI...

Страница 27: ...nal injury or loss of life A This appliance is equipped with an igni tion device which automatically lights the pilot Do not light pilot by hand B BEFORE LIGHTING smell all around the appliance area f...

Страница 28: ...be performed 4 Push in gas control knob slightly and turn clockwise to OFF 5 Close lower louver panel MANUAL LIGHTING PROCEDURE 1 Remove glass door see Removing Re placing Glass Door page 25 2 Follow...

Страница 29: ...center of the room facing towards the fireplace Note Do not hold the hand held remote for a long time Body temperature will affect its operation in the AUTO mode Safety Features When away from home f...

Страница 30: ...not operate Note for BKT Only If you are using BKT blower with optional thermostat wall mounted or remote control for fireplace your fireplace and blower will not turn on and off at the same time Fire...

Страница 31: ...a qualified service person Fireplace may need more frequent cleaning due to excessive lint from carpeting bedding material pet hair etc GLASS DOOR WARNING Handle glass door panel with care Do not stri...

Страница 32: ...th compressed air to remove dust dirt or lint Use a vacuum cleaner or small soft bristled brush to remove excess dust dirt or lint Logs If you remove logs for cleaning refer to Installing Lava Rock an...

Страница 33: ...hen in stalled 5 Depleted gas supply pro pane LP models only 6 Pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or...

Страница 34: ...y 2 Clean burner see Cleaning and Maintenance page 31 or replace burner orifice 1 Clean burner see Cleaning and Maintenance page 31 or replace burner orifice 2 Replace damaged burner 3 Replace gas con...

Страница 35: ...ck vent configuration specifications see Venting Installation page 9 1 This is normal If noise is excessive contact qualified service person 1 Replace 9 volt batteries in receiver and hand held remote...

Страница 36: ...ak See Warning statement above 2 Control valve defective 1 Gas leak See Warning statement above OBSERVED PROBLEM Fireplace produces un wanted odors Fireplace shuts off in use Gas odor even when contro...

Страница 37: ...f they can t supply original replacement part s call DESA Heating LLC at 1 866 672 6040 When calling DESA Heating LLC have ready your name your address model and serial numbers of your heater how heat...

Страница 38: ...www desatech com 116226 01K 38 Parts Models Kc36N VKc36N Kc36P and VKc36P Series 6 7 20 17 18 13 2 12 19 8 1 4 11 9 14 3 16 5 15 10 24 21 23 22 25 26...

Страница 39: ...1 02 Bottom Louver Assembly 1 6 Fireplace Top 1 7 Fireplace Top Insulation 1 8 Fireplace Surround 1 9 109082 01 Heat Shield 1 10 116541 01 Burner Assembly NG see page 40 1 116541 02 Burner Assembly LP...

Страница 40: ...www desatech com 116226 01K 40 PARTS Burner assembly models KC36N VKC36N KC36P AND VKc36P Series 7 15 10 12 1 12 2 3 13 9 11 21 22 TPTH TP TH 6 12 14 18 17 17 18 19 20 16 14 8 4 5...

Страница 41: ...1 9 111288 02 Flex Gas Line 1 10 108084 02 Pilot Assembly NG 1 108084 03 Pilot Assembly LP 1 108084 05 Pilot Assembly HA Models 1 11 14389 Natural Gas Valve 1 14390 Propane LP Gas Valve 1 117370 01 Na...

Страница 42: ...er If they can not supply these accessories call DESAHeating LLC at 1 866 672 6040 for information You can also write to the address listed on the back page of this manual Brick Liner KIT BL36DA Textu...

Страница 43: ...the comfort of your easy chair A wall mounted docking station is included Accessories Continued Receiver and Hand Held on off Remote Control Kit HRC100 Series Allows the fireplace to be turned on and...

Страница 44: ...ns furnished with this product This warranty covers the cost of part s required to restore this product to proper operating condition and an allowance for labor when provided by a DESA Heating LLC Aut...

Отзывы: