HIGH ALTITUDE INSTALLATION
Your DESA direct-vent fireplace has been CSA tested and approved
for elevations from 0-2000 feet (USA) and elevations from 0-4500
feet (Canada).
When installing this fireplace at an elevation above 2000 feet (in the
USA), you may need to decrease the input rating by changing the
existing burner orifice to a smaller size. Reduce input 4% for each
1000 feet above sea level. Check with your local gas company for
proper orifice size identification.
When installing this fireplace at an elevation above 4500 feet (in
Canada), check with local authorities.
Consult your local gas company to help determine the proper orifice
for your location.
For assistance with any high altitude installation contact DESA
Customer Service Department at 1-866-672-6040.
PARTS LISTS FOR VENTING KITS AND
COMPONENtS
DESA (5/8") Pipe & Vent Kits
Number Description
01492
Horizontal Square Termination Kit
Includes: 45° Elbow (Through 5" Wall), Wall Fire-
stop, Horizontal Square Termination
01493
Basic Vertical Termination Kit
Includes: Vertical Termination, Adjustable Flash-
ing, Storm Collar
01491
Horizontal Round Termination Kit
Includes: Round Termination, Wall Firestop, and
45° Elbow (Through 5" Wall)
01497
12" Section Coaxial Pipe - Galvanized (4)
01498
18" Section Coaxial Pipe - Galvanized (4)
01499
24" Section Coaxial Pipe - Galvanized (4)
01500
36" Section Coaxial Pipe - Galvanized (4)
01501
48" Section Coaxial Pipe - Galvanized (4)
01513
6" Section Coaxial Pipe - Galvanized (4)
01606
Adjustable 17"-24" Section Coaxial Pipe -
Galvanized (4)
F8030
Adjustable 7"-12" Section Coaxial Pipe
Galvanized (6)
D1032
Adjustable 7"-12" Section Coaxial Pipe
Galvanized (1)
DESA Elbows
Number Description
01502
45° Elbow - Galvanized (4)
01503
90° Elbow - Galvanized (4)
DESA Terminations
Number Description
01494
Vertical Round Termination - Galvanized (1)
01495
Horizontal Round Termination - Galvanized (1)
01496
Horizontal Square Termination - Galvanized (1)
01798
Vertical Round High Wind Termination (1)
01800
Horizontal Square High Wind Termination (1)
01801
14" Snorkel Termination - Galvanized (1)
01802
36" Snorkel Termination - Galvanized (1)
DESA Venting Accessories
Number Description
01504
Firestop Plate (4)
01505
Adjustable Roof Flashing 0 to 8/12 - Galvanized (6)
01506
Steep Pitch Flashing 9/12 to 12/12 - Galvanized (6)
01507
Storm Collar - Galvanized (4)
01508
Wall Strap (4)
01514
Combustible Siding Standoff - Galvanized (1)
01607
Wall Firestop - Galvanized (4)
VR-58
Vertical Restrictor - Galvanized
FiREPLAcE iNSTALLATioN
CHECK GAS tYPE
Use proper gas type for the fireplace unit you are installing. If you
have conflicting gas types, do not install fireplace. See retailer
where you purchased the fireplace for proper fireplace according
to your gas type.
INSTALLING OPTIONAL bLOWER
ACCESSORIES
NOtICE: If installing blower in an existing fireplace with
gas connections, shut off gas supply and disconnect
heater from gas supply. Contact a qualified service
person to do this.
WARNING: If there is a duplex electrical outlet in-
stalled in the right side of the bottom of the fireplace
base area, be sure that the electrical power to the outlet
is turned off before proceeding with blower installation.
Failure to do this may result in serious injury.
Model bK Installation
Follow all instructions provided in the blower accessory kit.
1. Attach the power cord to the blower motor by firmly pushing
the two female terminals at the end of the power cord onto the two
spade terminals on the blower motor (see Figure 25, page 15).
2. Attach green ground wire from power cord to blower housing
using screw provided (see Figure 25, page 15). Tighten screws
securely.