www.desatech.com
111826-04C
16
Changing The Code
The control is radio frequency operated. A code
(chosen from among 4,000 available codes)
is preset for all valves, but can be changed
if required (15 additional codes available).
Change DIP switch position. (The DIP switch
is located inside the hand held control at the
top of the battery compartment.) Then press the
receiver's reset button until you hear a second
(longer) signal. When pressing the
button
on the remote handset in the following 20 sec.,
the receiver learns the new code.
Shut-off Procedure
To save battery power; press
to turn main
gas to pilot gas. Press OFF button to shut off
the device including pilot flame. The device can
be shut off with ON/OFF switch, thus disabling
the remote hand set.
Setting The Display ( °C/24h and °F /12h)
Press and hold OFF and
until display
changes from °F (and 12 hour clock) to °C (and
24 hour clock) or vice versa.
Setting The Time
• After connecting the battery or by simulta-
neously pressing and the display will
start to flash. You are in the set mode.
• From SET mode press to set the hour and
to set the minute.
• Wait or press OFF to return to the manual
mode.
Battery Replacement
Remote handset battery needs to be changed
when LED is dim. Battery life expectancy is 2
to 3 years. Replacement is recommended at the
beginning of heating season. Battery needs to be
changed when acoustic error message appears
during ignition (see
Identifying Error Signals
from Receiver
on page 23).
Changing Mode of Operation
• Press the SET button quickly to change the
mode of operation in the following order:
MAN,
TEMP,
TEMP, TIMER.
• Manual flame height adjustment (
MAN
ap-
pears on display): Press to turn on the fire
(main burner) or to increase flame height.
Press
to decrease flame or to go down
to pilot only. The receiver acknowledges the
transmission with an acoustic signal.
• The day time temperature mode
(
TEMP
ap-
pears on display): The sensor in the transmitter
measures room temperature. The controller
compares the room temperature with set tem-
perature and sends a signal to the receiver to
turn the gas valve motor up or down, to adjust
the flame height accordingly.
• The nighttime setback temperature (
TEMP
appears on display): The sensor in the
transmitter measures the temperature and
adjusts it according to the nighttime setback
temperature. There is a bigger temperature
differential during this cycle.
• Timer: The timer mode (
TIMER
) operates
much like the temperature mode above. The
timer setting allows you to set specific times
for on and off. (There are 2 burner on and
2 burner off cycles every 24 hours.) If the
reading for the nighttime temp. is "– – –",
the motor will turn off the valve to standby
pilot position and wait for the next burner
on cycle. This display shows the setting tem-
perature every 30 seconds.
Setting the Temperature
• Select the desired mode of operation (day or
night) by pressing the
SET
button briefly.
• Hold the
SET
button until the display
flashes.
• Set the temperature with the or
(40°F
is the minimum temperature).
• Wait or press
OFF
to go to temperature
control mode.
• If temperature control in moon times should
be off (lower battery consumption), decrease
the night temperature until "– – –" appears
on display.
OPERATING HEATER
Continued
SET
OFF
STAND
BY
Figure 16 - Control Panel for Hand-Held
Remote