21
105647
OWNER’S MANUAL
For more information, visit www.desatech.com
CLEANING AND
MAINTENANCE
WARNING: Turn off heater
and let cool before cleaning.
CAUTION: You must keep con-
trol areas, burner, and circulating
air passageways of heater clean.
Inspect these areas of heater be-
fore each use. Have heater in-
spected yearly by a qualified ser-
vice person. Heater may need
more frequent cleaning due to
excessive lint from carpeting, pet
hair, bedding material, etc.
LOGS
• If you remove logs for cleaning, refer to
Installing Logs, page 12, to properly re-
place logs.
• Replace log(s) if broken or chipped
(dime-sized or larger).
BURNER PRIMARY AIR
HOLES
Air is drawn into the burner through the
holes in the fitting at the burner entrance.
These holes may become blocked with dust
or lint. Periodically inspect these holes for
any blockage and clean if needed. Blocked
air holes will create soot.
MAIN BURNER
Periodically inspect all burner flame holes
with the heater running. All slotted burner
flame holes should be open with yellow
flame present. All round burner flame holes
should be open with a small blue flame
present. Some burner flame holes may be-
come blocked by debris or rust, with no
flame present. If so, turn off heater and let
cool. Either remove blockage or replace
burner. Blocked burner flame holes will
create soot.
CLEANING BURNER
INJECTOR HOLDER AND
PILOT AIR INLET HOLE
The primary air inlet holes allow the proper
amount of air to mix with the gas. This pro-
vides a clean burning flame. Keep these holes
clear of dust, dirt, lint, and pet hair. Clean
these air inlet holes prior to each heating
season. Blocked air holes will create soot. We
recommend that you clean the unit every three
months during operation and have heater in-
spected yearly by a qualified service person.
We also recommend that you keep the burner
tube and pilot assembly clean and free of
dust and dirt. To clean these parts we recom-
mend using compressed air no greater than
30 PSI. Your local computer store, hard-
ware store, or home center may carry com-
pressed air in a can. You can use a vacuum
cleaner in the blow position. If using com-
pressed air in a can, please follow the direc-
tions on the can. If you don't follow direc-
tions on the can, you could damage the pilot
assembly.
1.
Shut off the unit, including the pilot.
Allow the unit to cool for at least thirty
minutes.
2.
Inspect burner, pilot, and primary air
inlet holes on injector holder for dust
and dirt (see Figure 41).
3.
Blow air through the ports/slots and
holes in the burner.
Figure 41 - Injector Holder On Outlet
Burner Tube
4.
Check the injector holder located at the
end of the burner tube again. Remove
any large particles of dust, dirt, lint, or
pet hair with a soft cloth or vacuum
cleaner nozzle.
5.
Blow air into the primary air holes on
the injector holder.
6.
In case any large clumps of dust have
now been pushed into the burner repeat
steps 3 and 4.
Clean the pilot assembly also. A yellow tip
on the pilot flame indicates dust and dirt in
the pilot assembly. There is a small pilot air
inlet hole about two inches from where the
pilot flame comes out of the pilot assembly
(see Figure 42). With the unit off, lightly
blow air through the air inlet hole. You may
blow through a drinking straw if compressed
air is not available.
Burner
Tube
Injector Holder
(May Be Brass
or Aluminum
Depending on
Model)
Primary Air Inlet
Holes (Shape of
Holes May Vary
by Model)
Figure 42 - Pilot Inlet Air Hole
Burner
Tube
Pilot
Assembly
Pilot Air
Inlet
Hole