background image

3

107050

OWNER’S MANUAL

Model EVGL850N is a radiant heat decora-
tive gas appliance that use an electronic gas
control valve with electronic ignition sys-
tem. A 5” B-Type venting system and a
listed type vent cap are not supplied but are
required for proper operation. See venting
instructions on pages 6 and 7.

This appliance, when installed, must be
electrically grounded in accordance with
local codes or, in the absence of local codes,
with the National Electrical Code, ANS/
NFPA 70
 or the Canadian Electrical Code,
CSA C22.1
.

The installation must conform with local
codes or, in the absence of local codes, with
the current National Fuel Gas Code, ANS
Z223.1
 or with the current CAN/CGA B149
Installation Codes
.

This appliance complies with ANS Z21.50-
1998
 and CSA 2.22-M98 as Vented Gas
Fireplaces 
and is listed and tested by the
Canadian Standards Association to the
above test standards.

INTRODUCTION

 WARNING: This gas appli-

ance must not be connected to a
chimney flue servicing a solid
fuel burning appliance.

• Model EVGL850N uses NATURAL

GAS ONLY.

If you have any doubts as to which gas your
particular unit is approved and tested for use
with, please check the rating plate located
behind the control access door (Figure 1,
page 2).

BEFORE YOU BEGIN

Before beginning the installation of your
appliance, read these instructions through
completely.

This DESA appliance and its approved com-
ponents are safe when installed according to
this installation manual and are operated as
recommended by DESA. Unless you use
DESA approved components tested for this
appliance, 

YOU MAY CAUSE A FIRE

HAZARD!

The DESA warranty will be voided by, and
DESA disclaims any responsibility for the
following actions :

A) Modification of the appliance or any of

the components.

B) Use of any component part not ap-

proved by DESA in combination with
this appliance.

C) Installation and/or operation in a man-

ner other than instructed in this manual.

D) The burning of anything other than the

type of gas approved for use in this gas
appliance.

 WARNING: Installation of this

appliance must be done by a quali-
fied service person well trained
in the installation of such appli-
ances. You will also need a build-
ing permit from your local Build-
ing and Safety Commissioner
before installing this appliance;
otherwise your insurance co. may
not cover this appliance.

 This appliance is not intended to
be used as a primary source of
heat.

 CAUTION: Do not connect

appliance before pressure test-
ing gas piping. Damage to gas
valve may result and an unsafe
condition may be caused.

The appliance and it’s individual equipment
shutoff valve must be disconnected from the
gas supply piping system during any pres-
sure testing of that system at test pressures
in excess of 1/2 psig (3.5 kPa).

The appliance must be isolated from the gas
supply piping system by closing its indi-
vidual equipment shutoff valve during any
pressure testing of the gas supply piping
system at test pressures equal to or less than
1/2 psig (3.5 kPa).

For the purpose of input adjustment two
pressure taps (for 

IN

 and 

OUT

 pressures)

are provided on the gas control valve for test
gauge connections to the appliance.

GAS RATING

Type of Gas

Natural

Max. Input Rating:

21,000 Btu/hr

Manifold Pressure:

3.5 in. WC (.87 kPa)

Minimum Supply Pressure:

4.5 in. WC (1.12 kPa)

Maximum Supply Pressure:

10.5 in. WC (2.66 kPa)

Orifice Size:

# 45

Содержание Vanguard EVGL850N

Страница 1: ...ediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed...

Страница 2: ...572mm 9 5 8 244mm 27 686mm 10 3 4 273mm Left Side 9 3 4 248mm Right Side 13 330mm 2 3 8 60mm 32 813mm 33 13 16 859mm HEARTH AREA DIMENSIONS TOP VIEW FRONT VIEW RIGHT SIDE VIEW FRONT INSIDE VIEW Figur...

Страница 3: ...MAY CAUSE A FIRE HAZARD The DESA warranty will be voided by and DESA disclaims any responsibility for the following actions A Modification of the appliance or any of the components B Use of any compo...

Страница 4: ...e yondanoutsidewall thiswouldalsoreduce the cutting of joists roof rafters and such Check local codes for any restrictions Projected installations can extend any distance into the room A projection ma...

Страница 5: ...iance see Figure 15 page 9 Figure 7 Rough Opening for Installing in Wall Figure 8 Rough Opening for Corner Installation 41 7 8 1061mm 15 381mm 36 1 4 921mm 59 1 4 1505mm 29 5 8 752mm 21 3 16 538mm COR...

Страница 6: ...l vertical system height Codes also allows only one offset in the total system when at 60 de grees or greater The total vertical height in thisexamplerepresentstheminimumheight of 8 feet and therefore...

Страница 7: ...struc tion see Figure 10 VENTING INSTALLATION Continued If venting horizontally through a side wall becomes necessary a listed thimble ap proved for use with B type vent must be used Check with your l...

Страница 8: ...e 12 2 Activate the remote handset battery by removing the insulating tab on the back of the handset see Figure 13 The bat tery is included pre installed 3 Once the battery is activated the unit is re...

Страница 9: ...lack iron gas line be routed from the gas source through a sediment trap shown in Figure 16 and into the appliance Once connected through the appliance a flexible gas line may be used for ease of inst...

Страница 10: ...log piece into the notches on the right side of the front and rear logs see Figure 23 NOTICE Do not put lava rock on burner or under burner Placing lava rock on burner could cause performance problems...

Страница 11: ...dividuals Ifthisisthecase pleaserequest help from someone else CAUTION For use with glass doorscertifiedwiththeappliance only CAUTION Do not operate theappliancewiththeglassdoor removed WARNING Childr...

Страница 12: ...call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas sup plier call the fire department C Do not use this appliance if any part has been...

Страница 13: ...l not require such purging 1 When lit for the first time the appli ance will emit a slight odor for an hour or two This is due to the curing of the logs and burn in of internal paints and lubricants u...

Страница 14: ...ne LP gas supply may be low When Gas Quality Is Bad pilot will not stay lit burner will produce flames and soot fireplace will backfire when lit Youmayfeelyourgaspressureistoolowor gas quality is bad...

Страница 15: ...imes to purge all air out of lines If after re peated attempts appliance does not light call for qualified service and repair 3 Remove debris and dirt inspect and clean any other possible obstructions...

Страница 16: ...page 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak SeeWarning statement at top of page 1 Improper log placement 2 Air holes at burner inlet blocked 3 Burner f...

Страница 17: ...inal replacement parts This will protect your warranty coverage for parts replaced under warranty PARTS UNDER WARRANTY Contactauthorizeddealersofthisproduct If theycan tsupplyoriginalreplacementpart s...

Страница 18: ...FIXED GLASS DOORS 01605 105863 01 IGNITION MODULE 14301 107221 01 TRANSFORMER 14129 107222 01 PILOT ASSEMBLY Natural Electronic 27197 107220 01 If in need of replacing have a qualified technician repl...

Страница 19: ...___________________ _______________________________________________________________________________________________ ____________________________________________________________________________________...

Страница 20: ...e the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES A...

Отзывы: