Desa (V)T32EN-A Series, (V)T32EP-A Скачать руководство пользователя страница 40

116647 01

116647-01
Rev. B
11/05

NOT A UPC

lIMITED WaRRaNTy

DIRECT-VENT FIREplaCE

DESA warrants this product to be free from defects in materials and components for two (2) years from the date 

of first purchase, provided that the product has been properly installed, operated and maintained in accordance 

with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must 

be presented.
This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to 

restore this heater to proper operating condition and an allowance for labor when provided by a DESA Authorized 

Service Center. Warranty part(s) MUST be obtained through authorized retailers of this product and/or DESA 

who will provide original factory replacement parts. Failure to use original factory replacement parts voids this 

warranty. The heater MUST be installed by a qualified installer in accordance with all local codes and instructions 

furnished with the unit.
This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts 

that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by 

improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to 

repairing a defective heater will be the responsibility of the owner.
TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE 

OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED 

WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING 

WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO TWO (2) 

YEARS ON ALL COMPONENTS FROM THE DATE OF FIRST PURCHASE; AND DESA’S LIABILITY 

IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA SHALL NOT BE 

LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR 

CONSEQUENTIAL DAMAGES.
Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of 

incidental or consequential damages, so the above limitation on implied warranties or exclusion or limitation on 

damages may not apply to you.
This warranty gives you specific legal rights and you may also have other rights that vary from state to state.
For information about this warranty write:

Model

Serial No.

Date Purchased

Always specify model and serial numbers when communicating with the factory.
We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our 

standard written warranty. We make no other warranty, expressed or implied.

WaRRaNTy INFORMaTION

kEEp ThIS WaRRaNTy

701 Industrial Drive
P.O. Box 90004
Bowling Green, KY 410-9004
www.desatech.com

Содержание (V)T32EN-A Series, (V)T32EP-A

Страница 1: ...damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to ligh...

Страница 2: ...fety Information Table of Contents Safety Information 2 Product Identification 4 Local Codes 4 Product Features 4 Pre Installation Preparation 5 Location of Termination Cap 7 Venting Installation Inst...

Страница 3: ...lid fuels wood coal paper cardboard etc in this fireplace Use only the gas type indicated on fire place name plate Carefully supervise young chil dren when they are in the room with fireplace SAFETY I...

Страница 4: ...rner Assembly Local Codes Install and use fireplace with care Follow all local codes In the absence to local codes use the cur rent National Fuel Gas Code ANSI Z223 1 NFPA 54 USA or the current CSA B1...

Страница 5: ...fireplace except where standoff spacers are integrally attached If standoff spacers are attached to your fireplace these spacers can be placed directly against wall or framing material See framing det...

Страница 6: ...ll minimum clearances must be met For available accessories for this fireplace see Accessories on page 33 If you are using a separate combustible mantel piece refer to Figure 6 for proper installation...

Страница 7: ...minimum L clearance above paved side walk or a paved driveway located on public property 84 inches 213 3cm minimum M clearance under veranda porch deck 12 inches 30 5cm minimum N clearance above a ro...

Страница 8: ...asurements when elbowing or offsetting Always use wall firestops when penetrating walls and firestops when penetrating ceilings or attic spaces Install horizontal venting with a 1 4 rise for every 12...

Страница 9: ...t one section clockwise approximately one quar ter turn until the sections are fully locked see Figure 8 Note Horizontal runs of vent must be supported every three feet Use wall straps for this purpos...

Страница 10: ...against the exterior fascia material 7 Combustible Exterior Wall Only Slidethewall firestop over the vent pipe before connecting horizontal run to vent cap see Figure 12 8 Carefully move fireplace wit...

Страница 11: ...UST be met IMPORTANT Remember that a horizontal run of venting must have a 1 4 rise for every 12 of run toward the termination WARNING Never run vent downward as this may cause excessive temperatures...

Страница 12: ...oor installation where pipe vents horizontally through wall over 12 horizontal pipe Basement installation where one foot clearance from ground to termination is possible SNORKEL TERMINATION INSTALLATI...

Страница 13: ...guration for Venting Using Two 90 Elbows Venting with Two 90 Elbows Horizontal H1 Vertical V Horizontal H1 Horizontal H2 5 min 2 max 6 max 6 min 4 max 12 max 7 min 6 max 18 max 8 min 8 max 20 max 20 m...

Страница 14: ...alling into the required clearance space Otherwise install firestop below the framed hole The firestop should be installed with no less than three nails per side see Figure 20 2 Assemble the desired l...

Страница 15: ...res 21 through 24 show four different con figurations for vertical termination Venting Installation instructions Continued Figure 21 Vertical Venting Configuration Using Two 90 Elbows with Two Horizon...

Страница 16: ...Department at 1 866 672 6040 parts list for venting kits and components DESA 5 8 Pipe Vent Kits Number Description P58 6 6 Section Double Wall Pipe Galvanized P58 12 12 Section Double Wall Pipe Galvan...

Страница 17: ...Installation CHECK GAS TYPE Use proper gas type for the fireplace unit you are installing If your gas supply is not correct do not install fireplace See retailer where you purchased the fireplace for...

Страница 18: ...n blower wheel Turn blower on and check for operation Turn blower off by turning knob fully counterclock wise before continuing 10 Peel off the backing paper and stick the sup plied wiring diagram dec...

Страница 19: ...ordingly 8 Turn on power to duplex outlet if previ ously turned off per the warning in column 2 page 17 9 Plug in blower power cord to duplex outlet 10 Theblowerwillonlyrunwhenthespeedcontrol knobisin...

Страница 20: ...gas pressure to between 11 and 14 inches of water If you do not reduce incoming gas pressure fireplace regulator damage could occur Install external regulator with the vent pointing down as shown in...

Страница 21: ...access holes on side of fireplace 3 Attach flexible gas line from gas supply to control valve see Figure 32 4 Check all gas connections for leaks See Checking Gas Connections Fireplace Installation C...

Страница 22: ...ive leak detection fluid to all joints Bubbles forming show a leak Correct all leaks at once 5 Light fireplace see Operating Fireplace page 23 Check all other internal joints for leaks 6 Turnofffirepl...

Страница 23: ...e 37 Removing Replacing Glass Door Lock Unlock Glass Frame Assembly Screw Hinge Latch 6 Replace screen rod assembly by reversing step 1 7 Replace louvers by reversing procedure under Removing Louver P...

Страница 24: ...r latches and open glass door See steps 1 and 2 of Remov ing Glass Door page 23 Install logs according to instructions for fireplace model numbers 1 Place log 1 rear log on top of grate Make sure the...

Страница 25: ...andset Battery Cover 12 Volt Battery Back of Handset Pull to Remove Insulation Tab WALL SWITCH INSTALLATION The installation of a wall switch allows you to ac tivate the gas control valve and turn the...

Страница 26: ...your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department C Do not use this appliance if any part has been under...

Страница 27: ...t be purchased separately see Accessories page 33 Follow installation instructions on page 25 1 Turn equipment shutoff valve to ON position You can now turn the burner on and off with the hand held re...

Страница 28: ...e 30 Figure 51 Typical Flame Pattern Cleaning and Maintenance WARNING Turn off fireplace and let cool before cleaning CAUTION You must keep control areas burners and circulating air passageways of fir...

Страница 29: ...ntrols should be cleaned with compressed air to remove dust dirt or lint Use a vacuum cleaner or small soft bristled brush to remove excess dust dirt or lint logs If you remove logs for cleaning refer...

Страница 30: ...on mod ule 2 Pilot flame too low to sense REMEDY 1 Check to see if you have gas supply and that equipment shutoff valve is opened 2 Repeat lighting procedure sev eral times to purge all air out of lin...

Страница 31: ...Gas Connections page 21 2 Replace control valve 1 Take apart gas tubing and remove foreign matter 2 Locate and correct all leaks see Checking Gas Connec tions page 21 1 Adjust the log set so that the...

Страница 32: ...ll DESA s Technical Service Department at 1 866 672 6040 When calling DESA have ready your name your address model and serial numbers of your fireplace how fireplace was malfunctioning type of gas use...

Страница 33: ...s Black Louver trim kit Rolled Louvers Only Not Shown LT32B Rolled Louver Trim Kit Brushed Brass LT32P Rolled Louver Trim Kit Platinum LT32PB Rolled Louver Trim Kit Polished Brass Deflection hoods Not...

Страница 34: ...647 01B 34 illustrated Parts Breakdown Models V T32EN A V T32ENB A V T32ENR A V T32ENRB A V T32EP A V T32EPB A V T32EPR A V T32EPRB A 6 7 21 18 19 10 13 2 12 20 8 11 1 14 9 17 3 15 4 16 5 16 22 2 22 6...

Страница 35: ...108890 01 108890 01 Burner Base Gasket 1 11 109082 03 109082 03 Heat Shield 1 12 108897 01 108897 01 Rear Refractory Brick Panel B Models Only 1 13 108901 01 108901 01 Right Refractory Brick Panel B...

Страница 36: ...GN D P V M V T R TH M V 21 23 24 26 25 27 17 22 16 14 20 12 9 8 10 13 15 19 18 28 29 11 2 1 7 3 5 4 6 illustrated parts breakdown BurnER Assembly Models V T32EN A V T32ENB A V T32ENR A V T32ENRB A V T...

Страница 37: ...25 Orifice 47 Natural 1 14514 Orifice 55 Propane LP 1 16 14528 Brass Elbow Fitting 1 17 108863 01 Supply Connect Plug 1 18 23416 Electronic Components Board 1 19 14129 Transformer 1 20 11147 Screw 10...

Страница 38: ...____ _____________________________________________________ _____________________________________________________ _____________________________________________________ _________________________________...

Страница 39: ...____ _____________________________________________________ _____________________________________________________ _____________________________________________________ _________________________________...

Страница 40: ...tation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner TO THE FULL EXTENTALLOWED BYTHE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF...

Отзывы: