SELECTING LOCATION

To determine the safest and most efficient location for your fire-
place, you must take into consideration the following guidelines:

1.

The location must allow for all the proper clearances (see Fig-
ure 2).

2.

Consider a location where the heat output would not be af-
fected by drafts, air conditioning ducts, windows or doors.

3.

A location that avoids the cutting of joists or roof rafters will
make installation easier.

4.

If an outside air kit is to be installed, accessibility to outside
combustion air must be considered. This can also be achieved
through a vented crawl space in some cases, for more details
refer to the section on outside air kit installation.

The typical installation for a V3610ST is a projected installation, which
allows you to extend the fireplace any distance into the room. A
projection may be ideal for a new addition on an existing, finished wall.

Figure 2 - Plan View of Common Location

CLEARANCES

MINIMUM CLEARANCES TO COMBUSTIBLES

Back ............................................. 1" Min.
Adjacent Wall ............................. 12" Min.
Chimney Outer Pipe Surfaces ...... 2" Min.
Bottom Of Fireplaces To Floor ..... 0" Min.

 CAUTION: Do not block required air spaces with

insulation or any other material. Do not obstruct
effective opening of fireplace with any type of facing
material. Combustible material must not be in con-
tact with the black front face of the fireplace.

Figure 3 - Fireplace Clearances

MANTLE CLEARANCES

Woodwork, such as wood trims, mantles, and other combustible
materials, should not be placed within 9 inches of the effective
opening of this fireplace.

Combustible material above and projecting more than 1 

1

/

2

 inches

from the fireplace’s front face (see Figure 4, page 5), should not be
placed less than 12 inches from the effective opening of the fireplace
(Ref: NFPA std.7-3.3.3.).

Mantles or any other combustible material may also come up to the
side edge of the black metal face of the fireplace, but only if the
projection from the front face falls within the limits shown in Figure
5, page 5.

FIREPLACE INSTALLATION

Selecting Location
Clearances
Mantle Clearances

FIREPLACE INSTALLATION

Содержание THE SAVANNAH V3610ST

Страница 1: ...is or any other appliance WARNING Improper installation adjust ment alteration service or maintenance cancauseinjuryorpropertydamage orloss of life Refer to this manual for correct instal lation and o...

Страница 2: ...Dia 38 7cm O D 10 Dia I D 25 4cm 24 60 9cm 6 15 2cm 52 3 4 134cm 17 40 6cm 10 1 4 26cm 11 1 4 28 5cm 7 177mm Outside Air Left Side View Front View Top View Gas Line Conduit 17 3 16 43 6cm 12 30 4cm 1...

Страница 3: ...rea providing ventilation and adequate combustion air IMPORTANT Read this owner s manual carefully and completelybeforetryingtoassemble operate orservice this fireplace Improper use of this fireplace...

Страница 4: ...all Figure 2 Plan View of Common Location CLEARANCES MINIMUM CLEARANCES TO COMBUSTIBLES Back 1 Min Adjacent Wall 12 Min Chimney Outer Pipe Surfaces 2 Min Bottom Of Fireplaces To Floor 0 Min CAUTION Do...

Страница 5: ...dtofityourrequiredplatformheight see Figure 8 The ember protector should be made of 28 gauge minimum galvanized sheet metal to prevent corrosion Figure 4 Mantel Clearances Figure 5 Mantel Clearances F...

Страница 6: ...e manufacturer or supplier or the noncombustible material Theminimumrequiredthicknessforanymaterialcouldbeobtained by the following formula K factor x 1 0 inch Thickness required 0 84 If the hearth ex...

Страница 7: ...vide rigidity for threaded end 4 Repack insulation around gas line and into sleeves openings Seal any gaps between gas line and refractory knockout hole with refractory cement or commercial furnace ce...

Страница 8: ...essary to add screws to keep vertical or angled chimney runs together Figure 16 Pipe Connection WARNING Theopeningaroundthestartercollaron topofthefireplacemustneverbeobstructed Neveruse blown insulat...

Страница 9: ...pace ELBOW OFFSET INSTALLATION Chimney weight above offset rests on return elbow Straps must be secured with nails to rafters or joists see Figure 19 Figure 19 Elbow Offset Figure 20 Chimney Supports...

Страница 10: ...run with 1 elbow set and 25 feet minimum for a run with 2 elbow sets A set consists of one starter elbow and one return elbow Uncommon circumstances such as neighboring hills tall trees or strong win...

Страница 11: ...ed for the pitch of your particular roof Figure 25 Roof Opening FINISHING YOUR CHIMNEY SYSTEM Maximum Chimney Height Cont Chimney Maintenance MINIMUM HEIGHT 15 FT 4 5m MAXIMUM HEIGHT CHASE TERMINATION...

Страница 12: ...many shingles as needed to cover exposed area and flashing base Secure in position by nailing through shingles DO NOT NAIL THROUGH FLASHING CONE Figure 26 Flashing Installation Storm Collar Installati...

Страница 13: ...proper clearances are adhered to and the fireplaceopeningsarenotobstructedinanyway RefertoClearances page 5 and Figure 30 Use only heat resistant noncombustible mortar or adhesive when securing facing...

Страница 14: ...ir and maintain safe temperatures in the firebox If operating with glass doors closed do so at this time Do not operate with doors par tially open Doors must be fully open or fully closed The glass mu...

Страница 15: ...load the grate or obstruct the required air space beneath it Always keep ashes from building up under the grate WARNING RISK OF FIRE Replace grate with DESA model 3610ST GR grate only Never obstruct t...

Страница 16: ...tedwiththisfireplacemayconstituteafirehazardandwillvoidtheDESAwarranty Storm Collar Storm Collar Comes With Wire Spacer Starter Elbow Return Elbow Vent Hood Vent Plaster Collar HEARTH EXTENSION KIT HE...

Страница 17: ...ompleted College Completed Graduate School 13 Age of Purchaser Under 20 20 29 30 39 40 49 50 59 60 or Over 14 Buyer s total annual household income Under 15 000 15 000 to 19 999 20 000 to 34 999 35 00...

Страница 18: ...55253C 18 For more information visit www desatech com For more information visit www desatech com 2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004 Postage Required TAPE TAPE...

Страница 19: ..._________________________________________________________ _______________________________________________________________________________________________ ______________________________________________...

Страница 20: ...55253C 20 For more information visit www desatech com For more information visit www desatech com 55253 Rev C 03 03 NOT A UPC 2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004 55253...

Отзывы: