background image

110373-01A

For more information, visit www.desatech.com

For more information, visit www.desatech.com

3

3

SAFETY INFORMATION

PRODUCT IDENTIFICATION

UNPACKING

1.

Install and use heater with care. Follow all local ordinances
and codes. In the absence of local ordinances and codes, refer
to the Standard for Storage and Handling of Liquefied Petro-
leum Gas, ANSI/NFPA 58
 and the Natural Gas Installation
Code, CAN/CGA B149.2.
 This instructs on the safe storage
and handling of propane/LP gases.

2.

This appliance is only for use with the type of gas indicated on
the rating plate. This appliance is not convertible for use with
other gases.

3.

This heater may be used in a recreational enclosure or temporary
construction work enclosure with a remote refillable propane/LP cyl-
inder ONLY when the cylinder is located outdoors and the heater is
used with the hose kit #LPA3090 (included with this heater). NEVER
bring a refillable propane/LP cylinder indoors. A fire or explosion
can occur causing property damage, serious injury or death.

4.

Use only the hose and factory preset regulator provided with
the heater. Use only replacement pressure regulators and hose
assemblies specified in this manual. See Accessories, page 18.

5.

Inspect the hose before each use of the heater. If it is evident there
is excessive abrasion or wear, or the hose is cut, it must be re-
placed prior to the heater being put into operation. Use replace-
ment hose assembly kit #LPA3090 (see Accessories, page 18).

6.

Use only propane gas set up for vapor withdrawal.

7.

This heater shall not be installed in a bedroom or bathroom.

8.

This heater needs fresh, outside air ventilation to run properly.
This heater has an Oxygen Depletion Sensing (ODS) safety
shutoff system. The ODS shuts down the heater if not enough
fresh air is available. You must provide a minimum 10 square
inches of ventilation air for adequate combustion.

9.

If heater shuts off, do not relight until you provide fresh, out-
side air. If heater keeps shutting off, have it serviced.

10. Keep all air openings in front and bottom of heater clear and free

of debris. This will insure enough air for proper combustion.

11. Do not use heater if any part has been under water. Immedi-

ately call a qualified service technician to inspect the room
heater and to replace any part of the control system and any
gas control which has been under water.

SAFETY INFORMATION

Continued

PRODUCT IDENTIFICATION

12. Turn off and let cool before servicing. Only a qualified service

person should service and repair heater.

13. Operating heater above elevations of 4,500 feet could cause

pilot outage.

14. Turn off propane/LP supply when not in use.

15. Check heater for damage before each use. Do not use a dam-

aged heater.

16. Do not alter heater. Keep heater in its original state.

17. Do not use heater if altered.

18. This heater can only be used in a recreational or commercial

enclosure with a window or roof vent. This heater is not for
outdoor use.

19. Before using the heater provide adequate ventilation.  An

area of 10 square inches of opening of a window or roof
vent is needed for adequate combustion and ventilation air.

Figure 1 - Vent-Free Propane/LP Gas Heater

Heater
Cabinet

Grill
Guard

Glass
Panel

Front
Panel

Control Knob

Ignitor
Button

Regulator
Hose

Any safety screen or guard removed for servicing the
appliance must be replaced prior to operating the
heater.

Keep the appliance area clear and free from combus-
tible materials, gasoline and other flammable vapors
and liquids.

UNPACKING

1.

Remove heater from carton.

2.

Remove all protective packaging applied to heater for shipment.

3.

Check heater for any shipping damage. If heater is damaged,
promptly return to dealer where you bought heater.

Содержание REM10PT

Страница 1: ...G Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to this manualforcorrectinstallationand operational procedures For as sistanceoradditionalinformation consult a qualified installer ser vice agency or the gas supplier WARNING This is an unvented gas fired heater It uses air oxy gen from the room in which it is installed Provisions for ad...

Страница 2: ... give off excessive carbon monoxide an odorless poisonous gas WARNING Early signs of carbon monoxide poi soning resemble the flu with headaches dizziness and nausea If you have these signs the heater may not be working properly Get fresh air at once Have heater serviced Some people including pregnant women people with heart or lung disease anemia those under the influence of alcohol and those at h...

Страница 3: ... not enough fresh air is available You must provide a minimum 10 square inches of ventilation air for adequate combustion 9 If heater shuts off do not relight until you provide fresh out side air If heater keeps shutting off have it serviced 10 Keep all air openings in front and bottom of heater clear and free of debris This will insure enough air for proper combustion 11 Do not use heater if any ...

Страница 4: ...e with the specifications for the propane LP gas cylin ders of the U S Department of Transportation DOT Use this heater only with a propane LP vapor withdrawal supply system See Chapter 5 of the Standard for Storage and Handling of LiquefiedPetroleumGas ANSI NFPA58and orCAN CGAB149 2 Your local library or fire department will have this booklet Theamountofpropane LPgasreadyforusefrompropane LPtanks...

Страница 5: ... solid walls concrete or masonry drill at least 1 1 4 deep 2 Fold wall anchor see Figure 4 Figure 3 Mounting Screw Locations Mounting Screw Locations 8 7 8 Minimum To Maintain 6 Clearance From Wall 7 3 4 20 1 4 Minimum To Maintain 3 Clearance From Floor FLOOR JOINING WALL INSTALLATION Continued Figure 4 Folding Anchor Figure 5 Popping Open Anchor Wings For Thin Walls Thin Walls 1 4 to 1 2 thick Fi...

Страница 6: ...ge 2 They are needed to safely operate this heater Follow all local codes when using this heater IMPORTANT Youmustuseapropane LPgassupplycylinderthat iscompatiblewiththeconnectiondeviceprovidedwiththehoseand regulator 1 Provide propane LP supply system see Propane LP Supply page 4 WARNING Test all gas piping and connections for leaks after installation or servicing Never use an open flame to check...

Страница 7: ...lling heater make sure you have the items listed below external regulator supplied by installer piping check local codes sealant resistant to propane LP gas equipment shutoff valve ground joint union test gauge connection sediment trap tee joint pipe wrench A CSA design certified equipment shutoff valve with 1 8 NPT tap is an acceptable alternative to test gauge connection The optional CSA design ...

Страница 8: ...e Cap Ground Joint Union 3 8 NPT Pipe Nipple Equipment Shutoff Valve From External Regulator 11 W C to 14 W C Pressure WARNING Test all gas piping and connections for leaks after installing or servicing Correct all leaks at once WARNING Never use an open flame to check for a leak Apply a noncorrosive leak detection fluid to all joints Bubbles forming show a leak Correct all leaks at once CAUTION M...

Страница 9: ...which has been under water WARNING If you do not follow these instructions exactly a fire or explosion may result causing prop erty damage personal injury or loss of life 3 Check all joints from supply tank to equipment shutoff valve see Figure 15 Apply a noncorrosive leak detection fluid to all joints Bubbles forming show a leak 4 Correct all leaks at once Pressure Testing Heater Gas Connections ...

Страница 10: ...ed the set temperature If so the burner willshutoff Theburnerwillcyclebackonwhenroomtemperature dropsbelowthesettemperature Thecontrolknobcanbesettoany heatlevelbetweenHIandLO SelectingtheHIsettingwillcausethe burnertoremainfullyonwithoutmodulatingdowninmostcases Note The thermostat sensing bulb measures the temperature of air near the heater cabinet This may not always agree with room temperature...

Страница 11: ...er off see To Turn Off Gas to Appliance page 10 see Troubleshooting pages 13 through 15 GRH OV 008 BAD PILOT LP GRH OV GOOD PILOT LP Thermocouple Pilot Burner Figure 18 Correct Pilot Flame Pattern Thermocouple Pilot Burner Figure 19 Incorrect Pilot Flame Pattern Figure 20 Correct Burner Flame Pattern 1 2 GLASS HEIGHT 1 2 GLASS HEIGHT Figure 21 Incorrect Burner Flame Pattern Yellow Tipping STORAGE ...

Страница 12: ...tore hardware store or home center may carry com pressed air in a can You can use a vacuum cleaner in the blow position If using compressed air in a can please follow the direc tions on the can If you don t follow directions on the can you could damage the pilot assembly 1 Shut off the unit including the pilot Allow the unit to cool for at least thirty minutes 2 Inspect burner pilot for dust and d...

Страница 13: ... clogged ODS pilot 7 Thermocouple damaged 8 Control valve damaged REMEDY 1 Replace pilot assembly 2 Replace pilot assembly 3 Reconnect ignitor cable 4 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 5 Tighten nut holding piezo ignitor to heater cabinet Nut is located inside heater cabinet at top 6 Replace ignitor cable 7 Replace piezo ignitor 1 Turn on gas supply or ope...

Страница 14: ...p for a minute 2 Operate burner until air is removed from line Have gas checked by local propane LP gas company 3 Observe minimum installation clear ances see Figure 2 page 4 4 Clean burner see Cleaning and Mainte nance page 12 or replace burner orifice POSSIBLE CAUSE 1 Burner orifice is clogged 2 Inlet gas pressure is too low 1 Manifold pressure is too low 2 Burner orifice is clogged 1 Burner ori...

Страница 15: ...qualified ser vice person 1 Ventilate room Stop using odor causing products while heater is running 2 Refill supply tank 3 Locate and correct all leaks see Check ing Gas Connections for Permanent Gas Supply page 9 1 Open window and or door for ventilation 2 Contact local propane LP gas company 3 Clean ODS pilot see Cleaning and Maintenance page 12 1 Locate and correct all leaks see Check ing Gas C...

Страница 16: ...ormation visit www desatech com For more information visit www desatech com 16 1 2 3 4 5 6 7 9 8 10 13 14 15 16 17 18 21 22 24 14 20 23 19 10 12 11 ILLUSTRATED PARTS BREAKDOWN REM10PT ILLUSTRATED PARTS BREAKDOWN REM10PT PILOT ...

Страница 17: ...s Panel 1 7 098532 06AA Top Glass Retainer 1 8 M11084 38 Screw 8 x 3 8 8 9 099317 02 Deflector Unit 1 10 098271 09 Ignitor Cable 1 11 098249 01 Nut M5 2 12 107667 02 ODS Pilot Assembly 1 13 104263 01 Burner 1 14 099387 11 Pilot Tubing 1 15 104259 06 Injector 1 Piece 1 16 NJF 8C Hex Nut 1 17 099415 13 Pressure Regulator 1 18 104261 01 Burner Tubing 1 19 104264 01 Regulator Tubing 1 20 098522 18 The...

Страница 18: ...ional SPECIFICATIONS TECHNICAL SERVICE SERVICE HINTS SERVICE PUBLICATIONS ACCESSORIES REPLACEMENT PARTS REPLACEMENT PARTS Note Use only original replacement parts This will protect your warranty coverage for parts replaced under warranty PARTS UNDER WARRANTY Contact authorized dealer from whom you purchased this product If they cannot supply original replacement part s call DESA International s Te...

Страница 19: ...al annual household income Under 15 000 15 000 to 19 999 20 000 to 34 999 35 000 to 49 999 50 000 to 74 999 75 000 to 99 999 100 000 and Over 14 Store where product was purchased Name ______________________________________ City _______________________ State __________ 15 In choosing this product how important were the following Availability Price Brand Name Overall Quality Heat Output Made in USA ...

Страница 20: ...110373 01A For more information visit www desatech com For more information visit www desatech com 20 2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004 Postage Required TM TAPE TAPE ...

Страница 21: ..._________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ ______________________________________________________...

Страница 22: ...inal factory replacement parts voids this warranty The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse accidents lack of proper maintenance or defects caused ...

Отзывы: