4. Open propane supply valve on propane tank(s) slowly. 

Note:

 If not opened

slowly, excess-flow check valve on propane tank will stop gas flow. If this
happens, close propane supply valve and open again slowly.

INSTALLATION

Continued

Figure 3 - Hose and Inlet Connector

LP-PFA/OV 008

Hose and Inlet Connector-LP275

Figure 2 - Regulator With Vent Pointing Down

Propane
Tank

1. Provide propane supply system (see Propane Supply, page 5).
2. Connect POL fitting on hose/regulator assembly to propane tank(s). Turn

POL fitting counterclockwise into threads on tank. Tighten firmly using
7/8" wrench. 

IMPORTANT:

 Tighten regulator with vent pointing down.

Pointing vent down protects regulator from weather damage.

Supply Valve

POL Fitting

Hose

Regulator

Vent
(pointing down)

3. Connect hose to the inlet connector. Tighten firmly using 9/16" wrench.

IMPORTANT:

 Use extra hose or piping if needed. Install extra hose or

piping between hose/regulator assembly and propane tank. You must use the
regulator supplied with heater even if propane tank has one.

Hose

Inlet Connector

WARNING ICON

G 001

 WARNING

Test all gas piping and connections for leaks after installation
or servicing. Never use an open flame to check for a leak.
Apply a mixture of liquid soap and water to all joints. Bubbles
forming show a leak. Correct all leaks at once.

WARNING ICON

G 001

 WARNING

Review and understand the warnings in the Safety Informa-
tion Section. They are needed to safely operate this heater.
Follow all local codes when using this heater.

Содержание RCP2000

Страница 1: ...01 GENERAL HAZARD WARNING FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PRO VIDED WITH THIS HEATER CAN RESULT IN DEATH SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE...

Страница 2: ...WARNING NOT FOR HOME OR RECREATIONAL VEHICLE USE The heater is designed for use as a construction heater The primary purpose of construction heaters is to provide temporary heating of buildings under...

Страница 3: ...heater Keep heater away from strong drafts water spray rain or dripping water Never attach duct work to heater Neverblockairinlet bottomofshell orairoutlet aroundtopofshell ofheater Keep children and...

Страница 4: ...g items applied to heater for shipment Keep plastic cover caps attached to inlet connector and hose regulator assembly for storage 2 Remove all items from carton 3 Check all items for shipping damage...

Страница 5: ...or one larger tank may be needed in colder weather Your local propane gas dealer will help you select the proper supply system Average Temperature F At Tank Location 60 40 32 20 10 0 Number Of Tanks...

Страница 6: ...nt down protects regulator from weather damage Supply Valve POL Fitting Hose Regulator Vent pointing down 3 Connect hose to the inlet connector Tighten firmly using 9 16 wrench IMPORTANT Use extra hos...

Страница 7: ...installation ventilation and safety information 2 Locate heater on stable and level surface Make sure strong drafts do not blow on heater WARNING ICON G 001 WARNING Fully close main burner valve befor...

Страница 8: ...towards the OFF position until it stops Note Arrows on main burner valve handle show direction for ON and OFF To Restart Heater 1 Wait five minutes after stopping heater 2 Restart heater by following...

Страница 9: ...rge air with automatic control valve button depressed 4 Replace pilot orifice 5 Adjust ignitor electrode gap to 120 Check wire lead for damage Replace piezo ignitor and or ignitor electrode as necessa...

Страница 10: ...ly original replacement part s either contact your nearest Parts Central or call DESA International s Technical Service Department at 1 800 323 5190 When calling DESA International have ready your nam...

Страница 11: ...Piezo Ignitor 1 18 098838 01 Sheet Metal Nut 1 19 LPA4010 Debris Shield 1 20 097155 01 Safety Control Valve 1 21 097157 01 Female Connector 1 22 098828 01 Female Compression Elbow 1 23 098835 01 Nut...

Страница 12: ...LUDING WARRANTIES OR MERCHANTABILITY AND FITNESS FOR A PARTICULAR PUR POSE DESA International assumes no responsibility for indirect incidental or consequential damages Some states do not allow the ex...