6
THEORY CUTAWAY 125 EURO
THEORY OF
OPERATION
WARNING
!
FUELS
Use only kerosene or No. 1 fuel oil to avoid risk of fire or
explosion. Never use gasoline, naphtha, paint thinners,
alcohol, or other highly flammable fuels.
Clean
Heated
Air Out
Cool
Air
In
Output
Air
Filter
Figure 3 - Cross Section Operational View
Spark
Plug
Burner
Head
Fan
Motor
Air Pump
Intake
Air Filter
Nozzle
Heat Exchanger
Outer Shell
Exhaust Gases
Outlet
Exhaust gases cross over
from combustion chamber
to heat exchanger
Fuel
Tank
Air line
To Burner
Electronic
Ignitor
Exhaust
Gases
Air For Fuel
System
Air For Combustion
And Heating
Fuel
The Fuel System:
The air pump forces air through the air line. The air is then
pushed through the burner head nozzle. This air causes fuel to lift from the tank.
A fine mist of fuel is sprayed into the combustion chamber.
The Air System:
The motor turns the fan. The fan pushes air into and around
the combustion chamber. This air is heated and provides a stream of clean, hot air.
Exhaust gases are ducted out of the heater through a vent pipe. The user must
supply the vent pipe.
The Ignition System:
The electronic ignitor sends voltage to the spark plug.
The spark plug ignites the fuel and air mixture.
The Safety Control System:
This system causes the heater to shut down if
the flame goes out.
Do not use heavy fuels such as No. 2 fuel oil or No. 2 Diesel. Using heavy fuels
will result in:
• clogged fuel filter and nozzle
• carbon build up on spark plug
• the need of non-toxic anti-icer in fuel during very cold weather
IMPORTANT:
Use a KEROSENE ONLY storage container. Be sure storage
container is clean. Foreign matter such as rust, dirt or water will cause the safety
control to shut down heater. Foreign matter may also require you to clean fuel
system often.
Содержание PRV125EDI
Страница 19: ...19 NOTES ...
Страница 20: ...099665 01 REV C 8 92 ...