background image

www.desatech.com

118620-01E

3

Natural and Propane/LP Gas: 

Natural and pro-

pane/LP gases are fuel gases. Fuel gases are 
odorless. An odor-making agent is added to 
fuel gases. The odor helps you detect a fuel 
gas  leak.  However,  the  odor  added  to  fuel 
gas can fade. Fuel gas may be present even 
though no odor exists.
Make  certain  you  read  and  understand  all 
warnings. Keep this manual for reference. It 

is your guide to safe and proper operation of 

this heater.

  WARNING:  Any  change  to 

this  heater  or  its  controls  can 

be dangerous.

  WARNING:  Do  not  use  a 

blower  insert,  heat  exchanger 

insert or other accessory not ap

-

proved for use with this heater.

Due  to  high  temperatures,  the 

appliance should be located out 

of traffic and away from furniture 

and draperies.

Do not place clothing or other 

flammable  material  on  or  near 

the appliance. Never place any 

objects on the heater.

Surface of heater becomes very 

hot when running heater. Keep 

children and adults away from 

hot  surface  to  avoid  burns  or 

clothing  ignition.  Heater  will 

remain hot for a time after shut-

down.  Allow  surface  to  cool 

before touching.

Carefully supervise young chil

-

dren when they are in the same 

room with heater.

Make sure grill guard is in place 

before running heater.

Keep  the  appliance  area  clear 

and free from combustible ma

-

terials, gasoline and other flam

-

mable vapors and liquids.

1.  This appliance is only for use with the type 

of gas indicated on the rating plate. This 
appliance is not convertible for use with 
other gases. 

2.  Do not place propane/LP supply tank(s) 

inside any structure. Locate propane/LP 
supply tank(s) outdoors.

3.  This  heater  shall  not  be  installed  in  a 

bedroom or bathroom.

4.  If you smell gas

• shut off gas supply
• do not try to light any appliance

• do not touch any electrical switch; do not 

use any phone in your building

• immediately call your gas supplier from 

a  neighbor’s  phone.  Follow  the  gas 

supplier’s instructions

• if  you  cannot  reach  your  gas  supplier, 

call the fire department

5.  This heater needs fresh, outside air ven

-

tilation to run properly. This heater has an 
Oxygen Depletion Sensing (ODS) safety 
shutoff system. The ODS shuts down the 
heater if not enough fresh air is available. 
See 

Air for Combustion and Ventilation,

 

page 5.

6.  Keep all air openings in front and bottom 

of heater clear and free of debris. This will 
insure enough air for proper combustion.

7.  If heater shuts off, do not relight until you 

provide fresh, outside air. If heater keeps 
shutting off, have it serviced.

8.  Do not run heater

• where flammable liquids or vapors are 

used or stored

• under dusty conditions

9.  Before using furniture polish, wax, carpet 

cleaner or similar products, turn heater 
off. If heated, the vapors from these prod

-

ucts may create a white powder residue 
within burner box or on adjacent walls or 
furniture.

10. Do not use heater if any part has been 

under water. Immediately call a qualified 

service  technician  to  inspect  the  room 
heater  and  to  replace  any  part  of  the 

control system and any gas control which 
has been under water.

SAFETY INFORMATION

Continued

Содержание NY100

Страница 1: ...WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the g...

Страница 2: ...irth defects or other reproductive harm IMPORTANT Read this owner s manual carefully and completely beforetryingtoassemble operate or service this heater Improper use of this heater can cause seri ous...

Страница 3: ...plate This appliance is not convertible for use with other gases 2 Do not place propane LP supply tank s inside any structure Locate propane LP supply tank s outdoors 3 This heater shall not be insta...

Страница 4: ...each purchaser a copy of 527 CMR 30 upon sale of the unit Vent free gas products are prohibited for bedroom and bathroom installation in the Commonwealth of Massachusetts Unpacking 1 Remove heater fr...

Страница 5: ...air that leaks around doors and windows may provide enough fresh air for combustion and ventilation However in buildings of un usually tight construction you must provide additional fresh air Unusuall...

Страница 6: ...l Gas Code ANSIZ223 1 NFPA54Section5 3 or applicable local codes DETERMINING FRESH AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this work sheet to determine...

Страница 7: ...mary heat source If you have a centralheatingsystem youmay run system s circulating blower whileusingheater Thiswillhelp circulatetheheatthroughoutthe house In the event of a power outage you can use...

Страница 8: ...ects arelessthan36 fromthefront top or sides of the heater as a fireplace insert in high traffic areas in windy or drafty areas Figure 4 Mounting Clearances As Viewed From Front of Heater INSTALLATION...

Страница 9: ...areas between studs or to solid walls concrete or masonry Decide which method better suits your needs Either method will provide a secure hold for the mounting bracket Marking Screw Locations 1 Tape m...

Страница 10: ...red key into wall anchor Push red key to pop open anchor wings see Figure 9 IMPORTANT Do not hammer key For thick walls over 1 2 thick or solid walls do not pop open wings 5 Place mounting bracket on...

Страница 11: ...n Sheet Metal Screw Wood Screw Base Foot Mounting Base Feet to Floor 1 Remove front panel see Removing Front Panel of Heater page 9 2 Position heater with base feet in desired location Mark holes for...

Страница 12: ...r CAUTION For propane LP gas never connect heater di rectly to the propane LP supply This heater requires an external regulator not supplied Install theexternalregulatorbetweenthe heater and propane L...

Страница 13: ...pplyanoncorrosiveleakdetec tion fluid to all joints Bubbles forming show a leak Correct all leaks at once CAUTION For propane LP gas make sure external regula tor has been installed between propane LP...

Страница 14: ...Correct all leaks at once Pressure Testing Heater Gas Connections 1 Open equipment shutoff valve see Figure 18 2 For natural gas open main gas valve located on or near gas meter For pro pane LP gas o...

Страница 15: ...TING INSTRUCTIONS 1 STOP Read the safety information column 1 2 Make sure equipment shutoff valve is fully open 3 Turn off any electric power to the appli ance if service is to be performed 4 Turn pil...

Страница 16: ...ter 30 seconds release control knob Now follow step 9 under Lighting Instructions page 15 5 Replace front panel UP DOWN SET TIME PROGRAM OFF SET PM ROOM Figure 24 Remote Control LCD Display Mode Butto...

Страница 17: ...button again and minute digits will begin flashing 4 Press UP or DOWN button until desired minutes are displayed 5 Press and release SET button on remote control to stop time digits from flashing and...

Страница 18: ...l or thermo mode If current time is not within program on time unit will stay off until pre programmed turn on time is reached Pre programmed time P 1 and P 2 icons will continue to display on screen...

Страница 19: ...on slide switch for selecting the mode of operation REMOTE OFF With slide switch in REMOTE position system will only operate if remote receiver receives commands from remote control With slide switch...

Страница 20: ...witch Code Switches Receiver Back of Remote Control Operating Blower This heater has a thermostatic blower that will automatically turn ON or OFF Note Your heater and thermostat blower will not turn o...

Страница 21: ...yearly by a qualified service person We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt To clean these parts we recommend using compressed air no great...

Страница 22: ...position 4 Air in gas lines when in stalled 5 Depleted gas supply pro pane LP gas only 6 ODS pilot is clogged 7 Gas regulator setting is not correct OBSERVED PROBLEM Whenignitorbuttonispressed there...

Страница 23: ...ane LP gas company 1 Contact local natural or propane LP gas company 2 Clean burner see Cleaning and Maintenance page 21 or replace burner orifice 1 Clean burner see Cleaning and Maintenance page 21 o...

Страница 24: ...ies not in stalled Battery power is low 3 Code settings on receiver and remote control do not match 4 Receiver and remote con trol too far apart REMEDY 1 Check burner for dirt and debris If found clea...

Страница 25: ...artially clogged 1 Gas leak See Warning statement above 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak See Warning statement above 1 Not enough combustion venti...

Страница 26: ...nder warranty Parts Under Warranty Contact authorized dealers of this product If they can t supply original replacement part s call DESA Heating Products Technical Ser vice Department at 1 866 672 604...

Страница 27: ...se Kit GA4550 For all models For locating heater on the floor away from a wall Complete installation and operating instructions included Electronic ignitor Kit GA435 Not Shown For all models Provides...

Страница 28: ...118620 01E 28 OFF PILOT ON 20 4 21 24 17 18 19 2 3 5 6 8 16 9 10 11 12 13 14 22 7 1 15 26 25 23 28 27 9 29 Illustrated Parts Breakdown Models nY100 nY101 nY102 nY103 nY104 nY105 nY106 nY107 nY114 nY11...

Страница 29: ...5 06 Injector 1 103845 07 Injector 1 103845 08 Injector 1 15 099066 02 Mounting Bracket 1 16 099415 17 Gas Regulator 1 099415 18 Gas Regulator 1 17 NJF 8C Hex Nut 1 18 118627 01 Burner Tube 1 19 11862...

Страница 30: ...1 0505 1 800 446 1446 www nbmc com Parts Centrals These Parts Centrals are privately owned businesses They have agreed to support our customer s needs by providing original replacement parts and acces...

Страница 31: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____...

Страница 32: ...roducts who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty The heater MUST be installed by a qualified installer in accordance wi...

Отзывы: