Страница 1: ...ectrical switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire dep...

Страница 2: ...pe of gas indicated on the rating plate This appliance is not convertible for use with other gases Aftermarket Completion of sale not for purpose of resale from the manufacturer WARNING This product c...

Страница 3: ...se with this fire place Due to high temperatures the appliance should be located out oftrafficandawayfromfurniture and draperies SAFETY Continued Do not place clothing or other flammable material on o...

Страница 4: ...oke less If logs ever appear to smoke turn off fireplace and call a qualified service person Note During initial operation slight smoking could occur due to log cur ing and fireplace burning manufactu...

Страница 5: ...e assembly The data plates contain important warranty and safety information 1 Remove fireplace from carton 2 Remove all protective packaging applied to fireplace for shipment 3 Make sure your firepla...

Страница 6: ...Figure 4 Assembling Trim Top Trim Mitered Edge Side Trim Slot Shim Adjusting Plate Set Screws Slot Figure 5 Attaching Trim to Compact Fireplace Assembled Trim Shoulder Screw Figure 2 Assembling Firep...

Страница 7: ...ilation Unusually Tight Construction The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation However in buildings of un usually tight construction you m...

Страница 8: ...__ Btu Hr maximum the space can support ________ Btu Hr actual amount used Air For Combustion and Ventilation Continued Example 51 200 Btu Hr maximum the space can support 56 000 Btu Hr actual amount...

Страница 9: ...NOTICE Thisheater isintended for use as supplemental heat Use this heater along with your primary heating system Do not install this heater as your pri mary heat source If you have a centralheatingsys...

Страница 10: ...RTANT Only use optional cabinet or corner mantels speci fied in this manual Purchase the optional mantel from your dealer see Accessories page 30 WARNING Never install the fireplace in a bedroom or a...

Страница 11: ...ies page 30 Brass trim will extend past sides of fireplace ap proximately 1 2 This will cover the rough edges of the wall opening If installing a built in mantel above the fireplace you must follow th...

Страница 12: ...leaks See Checking Gas Connections page 17 10 If using optional brass trim kit install the trim after final finishing and or painting of wall See instructions included with brass trim accessory for a...

Страница 13: ...shield off of the shoulder screw see Fig ure 15 Note If you do not have a short Phil lips screwdriver the screen log set and branch support must be removed so a longer screwdriver may be used See Con...

Страница 14: ...through the hole in left side of baffle Pull wire harness through lower opening above where valve shield was removed see Figure 16 7 Insert the 4 wire harness into one of the round holes in rear of v...

Страница 15: ...rd and tie it up with the plastic wire strap see Figure 19 Set the cable bundle between the burner bracket and outer casing away from the burner 6 Reinstall valve cover shield Figure 18 Wiring Diagram...

Страница 16: ...Figure 21 IMPORTANT Install an equipment shutoff valve in an access ble location The equip ment shutoff valve is for turning on and shut ting off the gas to the appliance Check your building codes fo...

Страница 17: ...o gas piping and or fittings 4 Apply pipe joint sealant lightly to male threads of gas connector attached to flexible gas line equipment shutoff valve see Figure 23 5 Check all gas connections for lea...

Страница 18: ...ly piping system by either opening propane LP supply tank valve for propane LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air 3 Check all joints fro...

Страница 19: ...l repairs are made light pilot with match To light pilot with match see Manual Lighting Procedure page 20 Ignitor Button Figure 27 Control Knob In the OFF Position Control Knob FOR YOUR SAFETY READ BE...

Страница 20: ...OL OPERATION The thermostatic control used on this fireplace differs from standard thermostats Standard thermostats simply turn on and off the burner The thermostat used on this fireplace senses the r...

Страница 21: ...orange for approximately one hour until the log cures If burner flame pattern is incorrect as shown in Figure 32 turn fireplace off see To Turn Off Gas to Appliance page 20 see Troubleshooting page 23...

Страница 22: ...ntrol areas burner and cir culating air passageways of fireplace clean Inspect these areas of fireplace before each use Have fireplace inspected yearly by a qualified service person Fireplace may need...

Страница 23: ...in PILOT position 4 Air in gas lines when in stalled 5 Depleted gas supply pro pane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Free ignitor cable if pinched by any...

Страница 24: ...low 2 Burner orifice is clogged 1 Burner orifice is clogged or damaged 2 Burner damaged 3 Low inlet gas pressure 4 Gas regulator defective REMEDY 1 Press in control knob fully 2 After ODS pilot light...

Страница 25: ...When heated vapors from furniture polish wax carpet cleaners etc may turn into white powder residue 1 Metal expanding while heat ing or contracting while cooling REMEDY 1 Check burner for dirt and de...

Страница 26: ...d 1 Gas leak See Warning statement at top of page 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak See Warning statement at top of page 1 Not enough combustion ve...

Страница 27: ...of your heater how heater was malfunctioning purchase date Usually we will ask you to return the part to the factory Parts Not Under Warranty Contact authorized dealers of this product If they can t s...

Страница 28: ...tech com 119508 01B 28 Parts Models LGCFTP AND LGCFTN 23 29 32 8 14 36 38 37 13 7 8 17 33 11 4 10 4 7 8 30 3 1 2 9 19 6 22 31 21 40 16 15 18 24 28 5 41 34 25 20 4 35 12 24 12 1 25 14 8 3 42 27 26 39 3...

Страница 29: ...649 02 Branch Support 1 21 099415 09 Gas Regulator 1 099415 10 Gas Regulator 1 22 102875 01 Regulator Bracket 1 23 101381 01 Valve Cover and Piezo 1 24 099387 11 Pilot Tube 1 25 098271 06 Ignitor Cabl...

Страница 30: ...corner design features clean classic lines Available in a stained oak 2 tone finish or an unfinished hardwood ready to stain or paint Complete assembly instruc tions included CABINET MANTEL with full...

Страница 31: ...D 1349 Adams Street Bowling Green KY 42103 270 846 1199 1 800 654 8534 Fax 1 800 846 0090 franktalk aol com Master Parts Dist 1251 Mound Ave NW Grand Rapids MI 49504 616 791 0505 1 800 446 1446 Fax 61...

Страница 32: ...proved by DESA Heating LLC Warranty parts must be obtained through authorized dealers of this prod uct and or DESA Heating LLC who will provide original factory replacement parts Failure to use origin...