background image

28

www.desatech.com

116238-01C

SERVICE HINTS

When Gas Pressure Is Too Low

•  pilot will not stay lit
•  burners will have delayed ignition
•  fireplace will not produce specified heat
•  propane/LP gas supply might be low (propane/LP units only)
You may feel your gas pressure is too low. If so, contact your local 

gas supplier.

TECHNICAL SERVICE

You may have further questions about installation, operation or 

troubleshooting. If so, contact DESAʼs Customer Service Depart-

ment at 1-866-672-6040. When calling, please have your model 

and serial numbers of your heater ready.
You  can  also  visit  DESAʼs  technical  service  web  site  at 

www.desatech.com

.

REPLACEMENT PARTS

Note:

 Use only original replacement parts. This will protect your 

warranty coverage for parts replaced under warranty. 

PARTS UNDER WARRANTY

Contact authorized retailers of this product. If they can not supply 

original replacement part(s), call DESAʼs Customer Service Depart-

ment at 1-866-672-6040.
When calling DESA, have ready
•  your name

•  your address

•  model and serial numbers of your fireplace 

•  how fireplace was malfunctioning

•  type of gas used (propane/LP or natural gas)

•  purchase date
Usually, we will ask you to return the part to the factory.

PARTS NOT UNDER WARRANTY

Contact authorized retailers of this product. If they can not supply 

original  replacement  part(s),  call  DESA  at  1-866-672-6040  for 

referral information.
When calling DESA, have ready
•  model number of your fireplace 

•  the replacement part number

REPLACEMENT PARTS
SERVICE HINTS
TECHNICAL SERVICE

Содержание KC36NE Series

Страница 1: ...a quali ed installer service agency or the gas supplier This appliance may be installed in an aftermarket permanently located manufactured mo bile home where not prohibited by state or local codes Thi...

Страница 2: ...nual carefully and completely before trying to assemble operateor service this replace Improper use of this replace can cause serious injury or death from burns re explosions electrical shock and carb...

Страница 3: ...per or other objects 13 Do not use any solid fuels wood coal paper cardboard etc in this replace Use only the gas type indicated on replace nameplate 14 This appliance when installed must be electrica...

Страница 4: ...pliance Due to high temperatures do not locate this replace in high traf c areas windy or drafty areas or near furniture or draperies Proper clearances must be maintained If your replace is to be inst...

Страница 5: ...replace as a heat source FRAMING AND FINISHING Figure4showstypicalframingofthis replace Figure5showsfram ing for corner installation All minimum clearances must be met For available accessories for th...

Страница 6: ...earance above paved side walk or a paved driveway located on public property 84 inches 213 3cm minimum M clearance under veranda porch deck 12 inches 30 5cm minimum N clearance above a roof shall exte...

Страница 7: ...wall restops when penetrating walls and restops when penetrating ceilings or attic spaces Install horizontal venting with a 1 4 rise for every 12 of run toward the termination WARNING Read all instru...

Страница 8: ...cking lugs indentations These lugs will slide straight into matching slots on the male ends of adjacent pipes Push pipe sections together and twist one section clockwise approxi mately one quarter tur...

Страница 9: ...the center of the 10 3 4 square hole and attach to exterior wall with wood screws provided see Figure 11 The siding standoff must sit ush against the exterior fascia material 7 Combustible Exterior W...

Страница 10: ...al minimum and maximum dimensions which MUST be met IMPORTANT Rememberthatahorizontalrunofventingmust have a 1 4 rise for every 12 of run toward the termination Figure 13 Typical Horizontal Terminatio...

Страница 11: ...sement installation where one foot clearance from ground to termination is possible SNORKEL TERMINATION INSTALLATION Recommended Applications Installations requiring a vertical rise on building exteri...

Страница 12: ...tion Planning Cont HORIZONTAL SYSTEM INSTALLATION USING TWO 90 ELBOWS The following con gurations show the minimum vertical rise re quirements for a horizontal system using two 90 elbows Venting with...

Страница 13: ...ove framed hole 2 Assemble the desired lengths of pipe and elbows necessary to reach from the replace ue up through the restop Be sure all pipe and elbow connections are fully twist locked see Figure...

Страница 14: ...Shown Venting with Two 90 Elbows Vertical V1 Horizontal H 5 min 6 max 6 min 12 max 7 min 18 max 8 min 20 max Note Vertical V1 Vertical V2 40 max Figure23 VerticalVentingCon gurationUsingTwo90 Elbows V...

Страница 15: ...with your local gas company for proper ori ce size identi cation When installing this replace at an elevation above 4500 feet in Canada check with local authorities Consult your localgas companyto hel...

Страница 16: ...Components FIREPLACE INSTALLATION Check Gas Type Installing Optional Blower Accessory PARTS LIST FOR VENTING KITS AND COMPONENTS DESA 5 8 Pipe Vent Kits Number Description P58 6 6 Section Double Wall...

Страница 17: ...LACE INSTALLATION Continued Speed Control Control Shaft Locknut Control Knob Switch Bracket Blower Plug In Duplex Outlet Located underneath rebox oor against lower right outside wall Thermodisc Figure...

Страница 18: ...lator with Vent Pointing Down Propane LP Only Propane LP Supply Tank External Regulator Vent Pointing Down 5 Mount the speed control box against the mounting plate provided in the lower replace cavity...

Страница 19: ...s for turning on or shutting off the gas to the appliance Checkyourbuildingcodesforanyspecialrequirementsforlocating equipment shutoff valve to replaces Apply pipe joint sealant lightly to male NPT th...

Страница 20: ...d on or near gas meter for natural gas replace 3 Make sure control knob of replace is in the OFF position 4 Check all joints from equipment shutoff valve to gas valve see Figure 34 for propane LP or F...

Страница 21: ...leaning Glass Door See Cleaning and Maintenance on page 25 Lock Unlock Glass Frame Assembly Screw Hinge Latch INSTALLING LAVA ROCK AND GLOWING EMBERS It is very important to keep logs exactly as insta...

Страница 22: ...39 Installing Rear Brick Panel Rear Brick Panel Left Side Brick Panel INSTALLING BRICK LINER MODELS BL36DA SA AND BL36DHA SA WARNING If replace has been running turn off and unplug replace Let cool b...

Страница 23: ...he wall switch to the ON position 11 Visuallylocatethepilot Theignitorshouldbegintosparkand the main burner should ignite once ame appears at pilot If lighting the appliance for the rst time each seas...

Страница 24: ...te control for the replace your replace and blower will not turn on and off at the same time The replacemayrunforseveralminutesbeforetheblower turns on After the heater modulates to the pilot position...

Страница 25: ...rom glass If glass has been broken carefully remove glass door see Remov ing Replacing Glass Door page 20 Vacuum all glass pieces with a shop vac CAUTION Do not vacuum if pieces are hot Use only the t...

Страница 26: ...all air out of lines If after re peated attempts appliance does not light call for quali ed service and repair 3 Remove debris and dirt inspect and clean any other possible obstructions 4 Contact your...

Страница 27: ...just after burner is lit or shut off Slight smoke or odor during initial operation Gas odor even when control knob is in OFF position Gas odor during combustion Glass soots Dark residue on logs or ins...

Страница 28: ...TS Note Use only original replacement parts This will protect your warranty coverage for parts replaced under warranty PARTS UNDER WARRANTY Contact authorized retailers of this product If they can not...

Страница 29: ...let Supply Pressure 5 5 w c 11 0 w c Dimension Inches mm HxWxD Fireplace Actual size of rebox Measurements do not 36 x 41 x 21 1 8 36 x 41 x 21 1 8 include nailing anges or 914 x 1041 x 537 mm 914 x 1...

Страница 30: ...h com 116238 01C ILLUSTRATED PARTS BREAKDOWN Models KC36NE VKC36NE KC36PE VKC36PE ILLUSTRATED PARTS BREAKDOWN MODELS KC36NE VKC36NE KC36PE AND VKC36PE 6 7 20 17 18 13 2 12 19 8 1 4 11 9 14 3 16 5 15 1...

Страница 31: ...ctory Brick Panel 1 12 see below see below Rear Refractory Brick Panel 1 13 see below see below Right Refractory Brick Panel 1 14 108719 01 108719 01 Screen Rod 1 15 12105 12105 Screen 2 16 11418 1141...

Страница 32: ...2 2 3 13 9 11 6 12 14 18 17 17 18 19 20 16 14 8 4 5 22 23 24 21 31 33 32 30 29 28 25 27 26 ILLUSTRATED PARTS BREAKDOWN Models KC36NE VKC36NE KC36PE VKC36PE ILLUSTRATED PARTS BREAKDOWN BURNER ASSEMBLY...

Страница 33: ...l 1 108866 02 Elec Pilot Assembly Propane LP 1 11 14569 Elec Valve Assembly Natural 1 14570 Elec Valve Assembly Propane LP 1 12 11165 Screw 10 x 5 8 Zinc 1 13 111913 01 Burner Base Gasket 1 14 14396 B...

Страница 34: ...L36DSA Standard Refractory Brick Liner Kit BL36DHA Textured Refractory Herringbone Brick Liner Kit BL36DHSA Standard Refractory Herringbone Brick Liner Kit Thisbricklineraddsatouchofstyletoyourdirect...

Страница 35: ...te School 13 Age of Purchaser Under 20 20 29 30 39 40 49 50 59 60 or Over 14 Buyer s total annual household income Under 15 000 15 000 to 19 999 20 000 to 34 999 35 000 to 49 999 50 000 to 74 999 75 0...

Страница 36: ...36 www desatech com 116238 01C 2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004 Postage Required TAPE TAPE...

Страница 37: ...______________________ ________________________________________________________________________________________________ ________________________________________________________________________________...

Страница 38: ...and all such other costs related to repairing a defective heater will be the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT...

Отзывы: