background image

www.desatech.com

121353-01F

25

OBSERVED PROBLEM

ODS/pilot  lights  but  flame 

goes  out  when  control  knob 

is released

Burner  does  not  light  after 
ODS/pilot is lit

Delayed ignition burner

Burner backfiring during com

-

bustion

POSSIBLE CAUSE

1. Control  knob  not  fully 

pressed in

2. Control knob not pressed in 

long enough

3. Equipment shutoff valve not 

fully open

4. Pilot  flame  not  touching 

thermocouple, which allows 
thermocouple to cool, caus

-

ing pilot flame to go out. This 

problem could be caused by 

one or both of the following:

  A) Low gas pressure

  B) Dirty or partially clogged 

ODS/pilot

5. Thermocouple  connection 

loose at control valve 

6. Thermocouple damaged
7. Control valve damaged

1. Burner orifice clogged

2. Inlet  gas  pressure  is  too 

low

3. Thermopile  leads  discon-

nected  or  improperly  con-
nected

4. Burners will not come on in 

remote position

1. Manifold  pressure  is  too 

low

2. Burner orifice clogged

1. Burner orifice is clogged or 

damaged

2. Damaged burner
3. Gas regulator defective

REMEDY

1. Press in control knob fully

2. After ODS/pilot lights, keep 

control knob pressed in 30 
seconds

3. Fully open equipment shut

-

off valve

4. A) Contact local natural or 

propane/LP gas company

  B)  Clean  ODS/pilot  (see 

Cleaning and Maintenance

page 23) or replace ODS/
pilot assembly

5. Hand  tighten  until  snug, 

then tighten 1/4 turn more

6. Replace pilot assembly
7. Replace control valve

1. Clean burner (see 

Cleaning 

and Maintenance

, page 23) 

or replace burner orifice

2. Contact  local  natural  or 

propane/LP gas company

3. Reconnect leads (see 

Wir-

ing Diagram

, page 24)

4. Replace battery in transmit-

ter and receiver

1. Contact  local  natural  or 

propane/LP gas company

2. Clean burner (see 

Cleaning 

and Maintenance

, page 23) 

or replace burner orifice

1. Clean burner (see 

Cleaning 

and Maintenance

, page 23) 

or replace burner orifice

2. Replace damaged burner
3. Replace gas control

TROUbLESHOOTING

Continued

Содержание FLAME-MAX VYM27NR

Страница 1: ...you cannot reach your gas supplier call the fire department Installation and service must be performed by a quali fied installer service agency or the gas supplier UNVENTED VENT FREE GAS LOG HEATER O...

Страница 2: ...t prohib ited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases Aftermarket Completion of sale...

Страница 3: ...g fans can create drafts that alter burner flame patterns Altered burner patterns can cause sooting Due to high temperatures the appliance should be located out oftrafficandawayfromfurniture and drape...

Страница 4: ...touch any electrical switch do not use any phone in your building immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions if you cannot reach your gas supplie...

Страница 5: ...Application These multisided logs are designed to be equally beautiful when viewed from any angle They are designed specifically for use in see through peninsula and island fireboxes with multiple op...

Страница 6: ...sidered a part of the unconfined space Adjoining rooms are communicating only if there are doorless passageways or ventilation grills between them There are 4 optional controls that can be pur chased...

Страница 7: ...pace can support _______ Btu Hr actual amount of Btu Hr used 40 000 33 000 73 000 Example 51 200 Btu Hr maximum the space can support 73 000 Btu Hr actual amount of Btu Hr used The space in this examp...

Страница 8: ...attic will activate the power vent NOTICE Thisheater isintended for use as supplemental heat Use this heater along with your primary heating system Do not install this heater as your pri mary heat so...

Страница 9: ...tural gas or propane LP gas but not both Gas type is indicated on the rat ingplate Fieldconversionisnot permitted INSTALLATION Continued INSTALLATION AND CLEARANCES Vent Free Operation Only WARNING Ma...

Страница 10: ...for minimum clearances IMPORTANT If you cannot meet these mini mum clearances you must operate heater with chimney flue damper open Go to Install ing Damper Clamp Accessory for Vented Operation page 1...

Страница 11: ...op of Fireplace Opening Underside of Mantel Shelf Mantel Shelf 12 A 18 20 22 24 All minimum distances are in inches 2 1 2 6 8 10 Figure 7 Minimum Mantel Clearances When Using Hood Minimum Noncombustib...

Страница 12: ...nce on the floor level you must maintain the minimum distance of 14 to combustibles see Figure 8 B If combustible materials are less than 14 to the fireplace you must install appliance at least 5 abov...

Страница 13: ...ble material Make sure material is secure CAUTION Do not pick up heater base assembly by the burner This could damage heater Only handle base as sembly by grates IMPORTANT Make sure the heater burner...

Страница 14: ...pplied Install the exter nalregulatorbetweentheheater and propane LP supply Figure 13 External Regulator With Vent Pointing Down Propane LP gas only Propane LP Supply Tank External Regulator with Vent...

Страница 15: ...uipment Shutoff Valve With 1 8 NPT Tap Approved Flexible Gas Hose if allowed by local codes Pipe Tee Nipple Cap Joint Sediment Trap Natural Gas From Gas Meter 5 W C to 10 5 W C Pressure Propane LP Gas...

Страница 16: ...iance main gas valve control valve and equip ment shutoff valve from gas supply piping system Pressures in excess of 1 2 psig will damage heater regulator 2 Cap off open end of gas pipe where equip me...

Страница 17: ...ylog If so reposition logs according to the log installation instructions in this manual Flames contact ing logs will create soot It is very important to install the logs exactly as instructed Do not...

Страница 18: ...whentheselectorswitch is in the ON position after the pilot is lit 4 Press in and turn control knob clockwise to the OFF position FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not fol low the...

Страница 19: ...release control knob If control knob does not pop out when released contact a qualified service person or gas supplier for repairs Note If pilot goes out repeat steps 4 through 8 9 Slightly push in an...

Страница 20: ...ctor switch to the REMOTE position see Figure 25 Note The burner may light if hand held re mote was on when selector switch was last turned off You can now turn the burner on and off with the hand hel...

Страница 21: ...held remote in the AUTO mode close to the fireplace The radiant heat from the fireplace will turn off the fireplace Ideally place the hand held remote in the center of the room facing towards the fir...

Страница 22: ...rn off heater and let cool Remove blockage blocked burner flame holes will create soot Burner FLAME PATTERN Figure 30 shows a correct burner flame pat tern Figure 31 shows an incorrect burner flame pa...

Страница 23: ...ollow the directions on the can If you don t follow directions on the can you could dam age the pilot assembly 1 Shut off unit including pilot Allow unit to cool for at least thirty minutes 2 Inspect...

Страница 24: ...OT position 3 Control knob not pressed in while in PILOT position 4 Air in gas lines when in stalled 5 Depleted gas supply pro pane LP gas 6 ODS pilot is clogged 7 Gas regulator setting is not correct...

Страница 25: ...position 1 Manifold pressure is too low 2 Burner orifice clogged 1 Burner orifice is clogged or damaged 2 Damaged burner 3 Gas regulator defective REMEDY 1 Press in control knob fully 2 After ODS pilo...

Страница 26: ...et cleaners etc may turn into white powder residue 1 Battery is not installed Bat tery power is low 1 Metal expanding while heating or contracting while cooling REMEDY 1 Check burner for dirt and debr...

Страница 27: ...ee Checking Gas Con nections page 15 1 Open window and or door for ventilation 2 Contact local natural or propane LP gas company 3 Clean ODS pilot see Cleaning and Maintenance page 23 1 Locate and cor...

Страница 28: ...ter how heater was malfunctioning purchase date Usually we will ask you to return the part to the factory Parts Not Under Warranty Contact authorized dealers of this product If they can t supply origi...

Страница 29: ...OL KIT HRC200 Allows the fireplace to be operated in a manu ally or thermostatically controlled mode You can turn the fireplace on and off without ever leaving the comfort of your easy chair A wall mo...

Страница 30: ...w desatech com 121353 01F 30 Parts Models VYM27NR and VYM27PR 5 1a 1b 1c 9 3 2 13 12 15 14 18 17 12 12 16 21 12 19 6 8 7 4 11 12 20 10 9 23 22 Note Part numbers 22 and 23 are for natural gas model onl...

Страница 31: ...ator to Pilot 1 099387 13 Pilot Tube Regulator to Pilot 1 10 103781 01 Gas Control Valve 1 103781 02 Gas Control Valve 1 11 104611 01 Lower Bracket 1 12 098304 01 Screw 8 x 0 38 7 13 Painted Base Asse...

Страница 32: ...proved by DESA Heating LLC Warranty parts must be obtained through authorized dealers of this prod uct and or DESA Heating LLC who will provide original factory replacement parts Failure to use origin...

Отзывы: