Desa EFS26NRA Скачать руководство пользователя страница 16

www.desatech.com

113110-01A

16

INSTALLATION

Continued

Propane/LP
Supply Tank

CONNECTING TO GAS SUPPLY

 WARNING: This appliance re-

quires a 45° male flare fitting 5/8"-
18 UNF (Unified National Fine
Thread) inlet connection and the
flexible gas line provided.

 WARNING: A qualified ser-

vice person must connect fire-
place to gas supply. Follow all
local codes.

 WARNING: Never connect

natural gas fireplace to private
(non-utility) gas wells. This gas
is commonly known as well-
head gas.

IMPORTANT: 

For natural gas, check gas line pres-

sure before connecting fireplace to gas line. Gas
line pressure must be no greater than 14 inches of
water. If gas line pressure is higher, heater regula-
tor damage could occur.

 CAUTION: Never connect pro-

pane/LP fireplace directly to the
propane/LP supply. This fireplace
requires an external regulator (not
supplied). Install the external
regulator between the fireplace
and propane/LP supply.

For propane/LP units, the installer must supply an
external regulator. The external regulator will re-
duce incoming gas pressure. You must reduce in-
coming gas pressure to between 11 and 14 inches
of water. If you do not reduce incoming gas pres-
sure, fireplace regulator damage could occur. In-
stall external regulator with the vent pointing down
as shown in Figure 20. Pointing the vent down
protects it from freezing rain or sleet.

Figure 20 - External Regulator With Vent

Pointing Down

 CAUTION: Use only new,

black iron or steel pipe. Inter-
nally-tinned copper tubing may
be used in certain areas. Check
your local codes. Use pipe of 1/2"
or greater diameter to allow
proper gas volume to fireplace. If
pipe is too small, undue loss of
volume will occur.

Installation must include an equipment shutoff
valve, union, and plugged 1/8" NPT tap. Locate
NPT tap within reach for test gauge hook up. NPT
tap must be upstream from heater (see Figure 21,
page 17).

IMPORTANT:

 Install equipment shutoff valve in

an accessible location. The equipment shutoff
valve is for turning on or shutting off the gas to
the appliance.

Check your building codes for any special re-
quirements for locating equipment shutoff valve
to fireplaces.

Apply pipe joint sealant lightly to male NPT
threads. This will prevent excess sealant from go-
ing into pipe. Excess sealant in pipe could result
in clogged fireplace valves.

 WARNING: Use pipe joint

sealant that is resistant to liquid
petroleum (LP) gas.

External Regulator

Vent Pointing Down

Содержание EFS26NRA

Страница 1: ...not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instruction...

Страница 2: ...n aftermarket permanently located manufactured mobile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not c...

Страница 3: ...arn ings Keep this manual for reference It is your guide to safe and proper operation of this fireplace WARNING Any change to this fireplace or its controls can be dangerous WARNING Do not use a blowe...

Страница 4: ...heated the vapors from these products may create a white powder residue within burner box or on adjacent walls or furniture 10 This fireplace needs fresh air ventilation to run properly This fireplace...

Страница 5: ...ce Do not re move at this time 2 Remove all protective packaging applied to fireplace for shipment 3 Make sure your fireplace includes one hard ware packet 4 Check fireplace for any shipping damage If...

Страница 6: ...ce heat loss in homes Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in During heating months home owners want their homes as airtight as possib...

Страница 7: ...FOR COMBUSTION AND VENTILATION Continued DETERMINING FRESH AIR FLOW FOR FIREPLACE LOCATION Determining if You Have a Confined or Unconfined Space Use this work sheet to determine if you have a confine...

Страница 8: ...an adjoining unconfined space you must provide two perma nent openings one within 12 of the ceiling and one within 12 of the floor on the wall connecting the two spaces see options 1 and 2 Figure 4 Yo...

Страница 9: ...be used in zero clearance installations Wall or framing material can be placed directly against any exterior surface on the rear sides ortopofyourfireplace exceptwherestand offspacersareintegrallyatta...

Страница 10: ...mbustible Material Side Wall and Ceiling A Clearances from the side of the fireplace cabi net to any combustible material and wall should follow diagram in Figure 6 Example The face of a mantel booksh...

Страница 11: ...p the firebox front facing WARNING Do not allow any combustible materials to over lap the firebox front facing IMPORTANT Noncombustible materials such as brick tile etc may overlap the front facing bu...

Страница 12: ...th the man tel for assembly instructions Refer to the follow ing instructions for system installation Refer to instructions on page 5 for fireplace assembly Blower accessory should be installed if it...

Страница 13: ...e as shown in Figure 13 4 Slide one end of adjusting plate shim in slot on mitered edge of top trim see Figure 13 5 Slide other end of adjusting plate shim in slot on mitered edge of side trim see Fig...

Страница 14: ...ly 3 2 1 Wire Harness Blower Bracket Assembly Screw Wire Harness Switch Baffle Wiring Routing Hole in Baffle Switch Plate Blue Red Valve Cover Shield Snap Bushing Black Blower Mounting Holes Lower Lou...

Страница 15: ...te Green White On 110 115 V A C Blower Motor Black Off 1 2 3 Auto Figure 19 Installing Blower Bracket Assembly Figure 18 Wiring Diagram For Blower Accessory Built In Installation Plastic Wire Strap Wi...

Страница 16: ...of water If you do not reduce incoming gas pres sure fireplace regulator damage could occur In stall external regulator with the vent pointing down as shown in Figure 20 Pointing the vent down protect...

Страница 17: ...hefireplace seeFigure22 The flexible gas supply line con nection to the equipment shutoff valve should be accessible 2 Route flexible gas line included from fireplace control to equipment shutoff valv...

Страница 18: ...sconnect appliance with its appliance main gas valve control valve and equipment shutoff valve from gas supply piping system Pressures in excess of 1 2 psig will damage heater regulator 2 Cap off open...

Страница 19: ...ropane LP Supply Tank Equipment Shutoff Valve Equipment Shutoff Valve Gas Meter Figure 26 Checking Gas Joints Natural Gas Only Gas Control Valve Gas Control Valve OPTIONAL WIRELESS HAND HELD REMOTE CO...

Страница 20: ...hermostat to any electrical source Electrical shock and or fire hazard will occur 1 Connect one terminal of 25 ft wire to bottom contact of switch see Figure 32 2 Connect remaining wire terminal to th...

Страница 21: ...ical source Electrical shock and or fire hazard will occur 1 Connect one terminal of 25 ft wire to bottom contact of switch see Figure 32 page 20 2 Connect remaining wire terminal to the TH terminal o...

Страница 22: ...be fore running fireplace NOTICE During initial operation ofnewfireplace burninglogswill give off a paper burning smell Open window to vent smell This will only last a few hours 1 STOP Read the safet...

Страница 23: ...Shutting Off Burners Only pilot stays lit You may shut off the burners and keep the pi lot lit by doing one of the following 1 Turn control knob clockwise to the PILOT position 2 Use remote control ma...

Страница 24: ...F mode button with the end of a paper clip or similar blunt object Manual Mode 1 Press the POWER and LOCK buttons to gether to turn on the hand held remote control 2 Press the MANU button to turn on t...

Страница 25: ...tion the blower will op erate constantly In the OFF position the blower will not operate In the AUTO position the blower will start when the thermostat senses a sufficient increase in firebox temperat...

Страница 26: ...air bedding material etc WARNING Failure to keep the primary air opening s of the burner s clean may result in sooting and property damage BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE The primary a...

Страница 27: ...e unit off lightly blow air through the air inlet hole You may blow through a drinking straw if compressed air is not available Figure 47 Injector Holder On Outlet Burner Tube Burner Tube Injector Hol...

Страница 28: ...position 4 Air in gas lines when installed 5 Depleted gas supply pro pane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable i...

Страница 29: ...d in 30 seconds 3 Wait one minute for safety in terlock system to reset Repeat ignition operation 4 Fully open equipment shutoff valve 5 A Contact local natural or propane LP gas company B Clean ODS p...

Страница 30: ...ecked by local natural gas company 3 Observe minimum installation clearances see pages 10 through 12 4 Cleanburner seeCleaningand Maintenance pages 26 and 27 or replace burner orifice 1 Turn fireplace...

Страница 31: ...If you cannot reach your gas supplier call the fire department IMPORTANT Operating fireplace where impurities in air exist may create odors Cleaning supplies paint paint remover cigarette smoke cement...

Страница 32: ...n Piezo Piezo Manifold Pressure 8 W C 3 5 W C Inlet Gas Pressure in of water Maximum 14 10 5 Minimum 11 5 Dimensions inches HxWxD Fireplace 25 7 8 x 26 13 16 x 9 3 8 25 7 8 x 26 13 16 x 9 3 8 includin...

Страница 33: ...LACEMENT PARTS Note Use only original replacement parts This will protect your warranty coverage for parts re placed under warranty PARTS UNDER WARRANTY Contact authorized dealers of this product If t...

Страница 34: ...STRATED PARTS BREAKDOWN REMOTE READY MODELS VMH26PRB VMH26NRB Shown EFS26PRA EFS26NRA 39 37 38 4 22 40 32 11 28 30 12 7 35 25 10 9 7 23 1 2 20 20 8 14 8 24 33 34 13 41 21 26 18 15 27 20 3 20 29 16 18...

Страница 35: ...86 02 Injector 1 20 M11084 26 M11084 26 Screw Hex Head 10 x 3 8 25 21 098249 01 098249 01 Nut M5 6 22 103781 02 103781 01 Gas Valve 1 23 102639 01 102639 01 Baffle 1 24 101628 01 101628 01 Flexible Co...

Страница 36: ...ing Black trim included with all mantels EXTRUDED LOUVER KIT Not Shown GA9092 Polished Brass GAP9092 Platinum For all models Optional extruded louver Kit con tains 2 louvers THERMOSTAT CONTROLLED BLO...

Страница 37: ...ed on the wall thermostat and the fire place will automatically cycle from pilot to the heat setting selected WALL MOUNT ON OFF SWITCH GWMS2 Not Shown For all models Allows the fireplace to be turned...

Страница 38: ...____________________________________ ___________________________________________________________ ___________________________________________________________ ___________________________________________...

Страница 39: ...____________________________________ ___________________________________________________________ ___________________________________________________________ ___________________________________________...

Страница 40: ...se original factory replacement parts voids this warranty The fireplace MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit This warr...

Отзывы: