ELECTRIC FIREPLACE
INSTALLATION INSTRUCTIONS
Models: (V)E32L, (V)E32LB, (V)E32LH, (V)E32LBH
V)E36L, (V)E36LB, (V)E36LH and (V)E36LBH
PRODUCT SPECIFICATIONS
HEARTH DIMENSIONS
Although not mandatory, a hearth extension is suggested for
aesthetic purposes. The appliance may be raised on a wood or
non-combustible platform supporting its entire width and depth
and extending in front of the appliance as long as the louvers are
not obstructed.
NOTE:
In cold climates, when installing the appliance against a
non-insulated exterior wall, outer wall must be fully insulated in
accordance with local building code.
FRAMING DIMENSIONS
Built-in installations require a framed-in enclosure constructed of
2 x 4 or heavier lumber and sized in accordance with Figure 5.
This allows the unit to slide into the opening and be nailed to the
stud space at the sides and top nailing flanges. These flanges
accept 5/8” drywall or plywood board to finish the unit flush to
the face. Optional trim accessories are available that will extend
½” over rough edge of the wall opening (see
Accessories
, page
21).
IMPORTANT:
If installing a perimeter trim kit, you must install
shoulder screws before inserting firebox into opening. See
instructions included with the trim kit. If installing a mantel above
the firebox, you must follow clearance instructions (see
Installation Clearances,
page 3).
4
7.0"
E32 = 7.0"
E36 = 8.0"
E32 = 18 3/8"
E36 = 21"
E32 = 35 3/8"
E36 = 42"
TO NAIL LOCATION
E32 = 34 5/8"
E36 = 41 1/4"
5/8"
E32 = 28 3/8"
E36 = 31 3/4"
E32 = 6 1/2"
E36 = 5 1/4"
E32 = 16 1/4"
E36 = 17 5/8"
E32 = 22 1/4"
E36 = 24 1/4"
E32 = 28 3/8"
E36 = 31 3/4"
E32 = 32 5/8"
E36 = 36 1/4"
Location
Electrical
Conduit
E32 = 32 7/8"
E36 = 36 1/2"
TO NAIL
LOCATION
E32 = 32 1/8"
E36 = 36 1/8"
E32 = 15 5/8"
E36 = 17"
1 7/8"
TOP
LEFT SIDE
RIGHT SIDE
FRONT
Location
Electrical
Conduit
E32 = 8"
E36 = 5 1/4"
E32 = 36 3/8"
E36 = 43"
E32 = 33 3/8"
E36 = 37"
E32 = 29 3/8"
E36 = 35"
ELECTRICAL
SPECIFICATIONS
Voltage:
Total Amps:
Total Watts:
Heater Rating:
Max. Bulb Rating:
Use only on 15 ampere branch circuit
120VAC, 60Hz
12.5 Amps
1500 Watts
1100 Watts
100 Watts
Figure 4 – Unit Dimensions
F
F
o
o
r
r
m
m
o
o
r
r
e
e
i
i
n
n
f
f
o
o
r
r
m
m
a
a
t
t
i
i
o
o
n
n
,
,
v
v
i
i
s
s
i
i
t
t
w
w
w
w
w
w
.
.
d
d
e
e
s
s
a
a
t
t
e
e
c
c
h
h
.
.
c
c
o
o
m
m
E32 = 34 5/8"
E36 = 41 1/4"
E32 = 32 5/8"
E36 = 36 1/4"
PLATEFORM/SUBFLOORING
Figure 5 - Framing Dimensions
E32 = 52 3/4"
E36 = 58 1/4"
E32 = 26 5/8"
E36 = 29 3/8"
E32 = 37 5/8"
E36 = 41 3/8"
11 5/8"
FOR 11 - 5/8" OF CLEARANCE
TO THE SIDE WALL
OF THE FIREPLACE
IS ALSO PERMITTED TO
HOWEVER, 10" CLEARANCE
PERPENDICULAR SIDE WALLS
THESE DIMENSIONS ALLOW
Figure 6 - Corner Dimensions
111076-01C