background image

www.desatech.com

119347-01A

3

 WARNING: This product con-

tains and/or generates chemicals 

known to the State of California 

to cause cancer or birth defects 

or other reproductive harm.

IMPORTANT: Read this owner’s 

manual carefully and completely 

before  trying  to  assemble,  op-

erate  or  service  this  fireplace. 

Improper  use  of  this  fireplace 

can  cause  serious  injury  or 

death  from  burns,  fire,  explo-

sion, electrical shock and carbon 

monoxide poisoning.

 DANGER: Carbon monoxide 

poisoning may lead to death!

Carbon  Monoxide  Poisoning:

  Early  signs  of 

carbon monoxide poisoning resemble the flu, with 

headaches, dizziness or nausea. If you have these 

signs, the fireplace may not be working properly. 

Get fresh air at once!

 Have fireplace serviced. 

Some people are more affected by carbon monoxide 

than others. These include pregnant women, people 

with heart or lung disease or anemia, those under the 

influence of alcohol and those at high altitudes.

Natural and Propane/LP Gas:

 Natural and propane/

LP gases are odorless. An odor-making agent is 

added to these gases. The odor helps you detect a gas 

leak. However, the odor added to the gas can fade. 

Gas may be present even though no odor exists.

Make certain you read and understand all warnings. 

Keep this manual for reference. It is your guide to 

safe and proper operation of this fireplace.

  WARNING:  Any  change  to 

this  heater  or  its  controls  can 

be dangerous.

  WARNING:  Do  not  use  a 

blower  insert,  heat  exchanger 

insert or other accessory not ap-

proved for use with this heater.

SAFEtY INFORMAtION

Continued

 WARNING: Do not allow fans 

to blow directly into the fireplace. 

Avoid any drafts that alter burner 

flame patterns. Ceiling fans can 

create  drafts  that  alter  burner 

flame  patterns.  Altered  burner 

patterns can cause sooting.

Due  to  high  temperatures,  the 

appliance should be located out 

of traffic and away from furniture 

and draperies.

Do not place clothing or other 

flammable  material  on  or  near 

the appliance. Never place any 

objects on the heater.

Heater base assembly becomes 

very  hot  when  running  heater. 

Keep children and adults away 

from hot surface to avoid burns 

or  clothing  ignition.  Heater 

will remain hot for a time after 

shutdown. Allow surface to cool 

before touching.

Carefully  supervise  young  chil-

dren when they are in the room 

with heater.  

You  must  operate  this  heater 

with a fireplace screen in place. 

Make  sure  fireplace  screen  is 

closed before running heater.

Keep  the  appliance  area  clear 

and free from combustible ma-

terials, gasoline and other flam-

mable vapors and liquids.

f i r e - p a r t s . c o m

Содержание CSL2718N

Страница 1: ...in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service mus...

Страница 2: ...s for installation only in a solid fuel burning mason ry or UL127 factory built fireplaceorinalistedvent lessfireboxenclosure Itis design certified for these installations in accor dance with ANSI Z21...

Страница 3: ...Make certain you read and understand all warnings Keep this manual for reference It is your guide to safe and proper operation of this fireplace WARNING Any change to this heater or its controls can b...

Страница 4: ...orsclosed heatbuildupinsidefire placewillcauseglasstoburst Makesurethereare no obstructions across openings of fireplace 9 This log heater is designed to be smokeless If logs ever appear to smoke turn...

Страница 5: ...ace or unusually tight con struction unless provisions are provided for adequate combus tionandventilationair Readthe following instructions to insure proper fresh air for this and other fuel burning...

Страница 6: ...A 54 defines a confined space as a space whose volume is less than 50 cubic feet per 1 000 Btu per hour 4 8 m3 per kw of the aggregate input rating of all appliances installed in that space and an unc...

Страница 7: ...n5 3 or applicable local codes VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining un confined space When ventilating to an adjoining unconfined space you...

Страница 8: ...the rating plate This appliance is not convertible for use with other gases WARNING This appliance is equipped for natural or pro pane LP gas Field conversion is not permitted Installation NOTICE Thi...

Страница 9: ...16 from Side Wall Example INSTALLATION Continued NOTICE Manual control heaters may be used as a vented product If so you must always run heater with chimney flue damper open If running heater with da...

Страница 10: ...ances listed below you will need a hood Determining Minimum Mantel Clearance If you meet minimum clearance between mantel shelf and top of fireplace opening a hood is not required see Figure 6 INSTALL...

Страница 11: ...nted heater appliance must be installed only in a solid fuel burning fireplace with a working flue and constructed of noncombustible material You may use this heater as a vented product There are thre...

Страница 12: ...resistant to propane LP gas not provided electric drill with 3 16 drill bit flathead screwdriver 1 Apply pipe joint sealant lightly to male threads of the fitting to be threaded into gas regulator Con...

Страница 13: ...egulator will reduce incoming gas pressure You must reduce incoming gas pressure to between 11 and 14 of water If you do not reduce incoming gas pres sure heater regulator damage could occur Install e...

Страница 14: ...stem by either opening propane LP supply tank valve for propane LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air 4 Check all joints of gas supply p...

Страница 15: ...ng Heater page 16 Check all other internal joints for leaks 7 Turn off heater see To Turn Off Gas to Appli ance page 17 INSTALLING Log WARNING Failuretoposition thepartsinaccordancewiththese diagrams...

Страница 16: ...control system and any gas control which has been under water LIGHTING INSTRUCTIONS WARNING If fireplace has glass doors never operate this heater with glass doors closed If you op erateheaterwithdoo...

Страница 17: ...olknobcoun terclockwise to desired heating level The burner should light Set control knob to any heat level between HI and LO WARNING Do not operate heaterbetweenPILOTandHIGH positions Figure 19 Contr...

Страница 18: ...lot Burner Pilot Burner Thermocouple Propane LP Natural Gas BURNER PRIMARY AIR HOLES Air is drawn into the burner through the holes in the fitting at the entrance to the burner These holes may become...

Страница 19: ...clumpsof dusthave now been pushed into the burner repeat steps 3 and 4 Clean the pilot assembly also Ayellow tip on the pilot flame indicates dust and dirt in the pilot as sembly There is a small pilo...

Страница 20: ...talled 5 Depleted gas supply propane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct OBSERVED PROBLEM When ignitor button is pressed there is no spark at ODS pilot When ignitor b...

Страница 21: ...atural or pro pane LP gas company 1 Contact local natural or pro pane LP gas company 2 Clean burner see Cleaning and Maintenance page 18 or replace burner orifice 1 Clean burner see Cleaning and Maint...

Страница 22: ...until air is removed from line Have gas line checked by local natural or propane LP gas company 3 Observe minimum installation clearances see page 8 4 Clean burner see Cleaning and Maintenance page 18...

Страница 23: ...ecking Gas Connec tions page 14 1 Open window and or door for ventilation 2 Contact local natural or pro pane LP gas company 3 Clean ODS pilot see Cleaning and Maintenance page 18 1 Locate and correct...

Страница 24: ...ll have delayed ignition heater will not produce specified heat propane LP gas supply may be low You may feel your gas pressure is too low If so con tact your local natural or propane LP gas supplier...

Страница 25: ...arts Centrals are privately owned businesses They have agreed to support our customer s needs by providing original replacement parts and accessories Tool Equipment Co 5 Manila Ave Hamden CT 06514 032...

Страница 26: ...desatech com 119347 01A 26 15 17 18 16 9 5 6 7 19 16 4 11 3 19 19 14 2 27 12 13 8 10 1 Illustrated Parts Breakdown Variable Manually Controlled Winchester Oak Models CSL2718N AND CSL2718P fire parts...

Страница 27: ...Burner Orifice Injector 1 099056 21 Burner Orifice Injector 1 9 111124 01 Burner Retainer Spring 1 10 102963 02 Burner 1 11 102568 07 Control Valve 1 102568 08 Control Valve 1 12 098508 01 Valve Retai...

Страница 28: ...ualified installer in accordance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in original condition because of normal wear and tear...