105683

OWNER’S MANUAL

For more information, visit www.desatech.com

INSTALLATION

Continued

OPERATING HEATER

FOR YOUR SAFETY

READ BEFORE

LIGHTING

 WARNING: If you do not fol-

low these instructions exactly, a
fire or explosion may result caus-
ing property damage, personal
injury or loss of life.

A. This appliance has a pilot which must

be lighted by hand. When lighting the
pilot, follow these instructions exactly.

B. BEFORE LIGHTING smell all

around the appliance area for gas. Be
sure to smell next to the floor because
some gas is heavier than air and will
settle on the floor.

WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do

not use any phone in your building.

• Immediately call your gas supplier

from a neighbor’s phone. Follow
the gas supplier’s instructions.

• If you cannot reach your gas sup-

plier, call the fire department.

C. Use only your hand to push in or turn

the gas control knob. Never use tools.
If the knob will not push in or turn
by hand, don’t try to repair it, call a
qualified service technician or gas
supplier. Force or attempted repair
may result in a fire or explosion.

D. Do not use this appliance if any part

has been under water. Immediately call
a qualified service technician to inspect
the appliance and to replace any part
of the control system and any gas con-
trol which has been under water.

Continued

13. Install plastic control knob onto output

shaft of speed control housing (see Fig-
ure 15). Place speed control housing
just inside control compartment door
in front of stove (see Figure 16).

14. Using two screws provided in blower

kit, mount blower speed control hous-
ing to mounting tab in left side of lower
control compartment (see Figure 16).

15. Check to make sure that the power cord is

completely clear of blower wheel and there
are no foreign objects in blower wheel.

16. Carefully replace stove top panel. Align

holes and replace six screws removed
in step 1.

17. Peel off the backing paper and stick

the supplied wiring diagram decal on
the stove floor bottom as shown in
Figure 15.

18. Plug power cord into a convenient 3-prong

grounded wall receptacle near the stove.

Figure 16 - Installing Blower Control Housing

Blower Speed
Control Housing

Power
Cord

Speed Control
Housing

Control
Knob

Figure 15 - Routing Power Cord

101584-05

120 Vac.   60 Hz. .  78 Amps
DESA International, Bowling Green, KY

Variable

Fan Switch 

White

White

Black

Green

On

110/115 

V.A.C.

Blower

Motor

Black

Black

Black

Off

 

WARNING: Never attempt to service heater while it

is plugged in, operating, or hot. Burns and electrical
shock could result. Only a qualified service person
should service or repair heater.

If any of the original wire as supplied with the appliance must be
replaced, it must be replaced with 105

°

C wire or it’s equivalent.

 WARNING: Label all wires prior to disconnection

when servicing controls. Wiring errors can cause im-
proper and dangerous operation. Verify proper opera-
tion after servicing.

Wiring
Diagram
Decal

19. Using speed control knob, turn blower

on and check for operation.

20. All remaining parts from blower kit

may be discarded.

 WARNING: ELECTRICAL

GROUNDING INSTRUCTIONS
This appliance is equipped with a
three-prong (grounding) plug for
your protection against shock
hazard and should be plugged
directly into a properly grounded
three-prong receptacle.

Содержание Comfort Glow S26NT

Страница 1: ...ce must be performed by a qualified installer service agency or the gas supplier WARNING Improper installa tion adjustment alteration ser vice ormaintenancecancause injury or property damage Re fer to...

Страница 2: ...tion of soot follow the instructions in Cleaning and Main tenance page 13 8 Before using furniture polish wax car pet cleaners or similar products turn heater off If heated the vapors from these produ...

Страница 3: ...1 Remove top inner pack 2 Tilt carton so that stove is upright 3 Remove protective side packaging 4 Slide stove out of carton 5 Remove protective plastic wrap 6 Remove screen by lifting and then pull...

Страница 4: ...herearedoorlesspassagewaysorventila tion grills between them WARNING This heater shall notbeinstalledinaconfinedspace or unusually tight construction unless provisions are provided foradequatecombusti...

Страница 5: ...iances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used _________________ Btu Hr ma...

Страница 6: ...igure 2 Ventilation Air from Inside Building VENTILATION AIR Ventilation Air From Inside Building Thisfreshairwouldcomefromanadjoining unconfined space When ventilating to an adjoining unconfined spac...

Страница 7: ...reater clearances from floor ceiling and adjoining side and back walls Carefullyfollowtheinstructionsbelow This stove is a freestanding unit designed to set directly on the floor IMPORTANT You must ma...

Страница 8: ...r cleaning Install in piping system betweenfuelsupplyandheater Locatesedi ment trap where trapped matter is not likely to freeze A sediment trap traps moisture and contaminants This keeps them from go...

Страница 9: ...connect heater and equipment shutoff valve to gas supply Check re connected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1 Close equipment shutoff valve see Fig ure 7 2 Pre...

Страница 10: ...onnectpowercordwiresfromblower motor if connected see Figure 12 4 Disconnect green ground wire from blower housing if connected by re moving screw holding wire terminal see Figure 12 5 Install one pla...

Страница 11: ...igure 16 14 Using two screws provided in blower kit mount blower speed control hous ing to mounting tab in left side of lower control compartment see Figure 16 15 Checktomakesurethatthepowercordis com...

Страница 12: ...pat tern Figure 20 shows an incorrect pilot flame pattern Note Appearance of pilot assembly may vary by model The incor rect pilot flame is not touching the thermo couple This will cause the thermoco...

Страница 13: ...cleanandfreeofdust and dirt To clean these parts we recommend using compressed air no greater than 30 PSI Yourlocalcomputerstore hardwarestore or home center may carry compressed air in a can You can...

Страница 14: ...ged 7 Control valve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor to base panel of log set...

Страница 15: ...ute 2 Operate burner until air is removed from line Have gas line checked by local natu ral gas company 3 Observe minimum installation clearances see pages 7 through 9 4 Clean burner see Cleaning and...

Страница 16: ...ater produces unwanted odors Heater shuts off in use ODS operates Gas odor even when control knob is in OFF position Gas odor during combustion Burner flame is excessively large and is very near or to...

Страница 17: ...4 x 27 1 4 x 17 1 4 Carton 22 x 31 x 31 1 2 Weight pounds Stove 66 lbs Shipping 80 lbs For purposes of input adjustment Baltimore Electric 1348 Dixwell Avenue Hamden CT 06514 0322 1 800 397 7553 203 2...

Страница 18: ...18 105683 VENT FREE NATURAL GAS PEDESTAL STOVE For more information visit www desatech com ILLUSTRATED PARTS BREAKDOWN S26NT 5 7 6 9 13 4 10 3 2 1 14 15 12 11 10 8...

Страница 19: ...t 1 2 14285 01 ODS Pilot NG 1 3 098249 01 ODS Nut 2 4 105973 01 Burner Outlet Tube 1 5 105737 01 Injector Holder 1 6 102843 01 Burner Clip 1 7 099056 27 Burner Orifice Injector 1 8 101329 25 Gas Contr...

Страница 20: ...20 105683 VENT FREE NATURAL GAS PEDESTAL STOVE For more information visit www desatech com ILLUSTRATED PARTS BREAKDOWN S26NT 1 4 13 3 2 14 7 16 15 11 18 10 5 6 9 8 17 12...

Страница 21: ...5661 01 Firebox Top Assembly 1 11 105970 01 Screen Assembly 1 12 101382 01 Valve Bracket 1 13 105672 01 Brass Trim Bottom 1 14 105673 01 Brass Trim Firebox 1 15 106754 01 Knob 1 16 105971 01 Door Hing...

Страница 22: ...Parts Central see page 17 If they can t supply original replacement part s call DESA International s Parts Department at 1 800 972 7879 for referral information WhencallingDESAInternational haveready...

Страница 23: ..._________________________________________ _______________________________________________________________________________________________ ______________________________________________________________...

Страница 24: ...sedbyimproperinstallation Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner TO THE FULL EXTEN...

Отзывы: