background image

15

104324

OWNER’S MANUAL

OPERATING
FIREPLACE

Continued

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Fireplace

1.

Turn control knob clockwise  
to the OFF position.

2.

Set remote selector switch in the OFF
position to prevent draining battery.

Shutting Off Burner Only (pilot
stays lit)

You may shut off the burners and keep
the pilot lit by doing one of the following:

1.

Turn control knob clockwise  
to the PILOT position.

2.

Use remote control manual OFF button.

3.

Set remote selector switch in the OFF
position.

THERMOSTAT

CONTROL

OPERATION

1.

Follow steps 1 through 6 under Light-
ing Instructions
, page 14.

2.

Depress control knob and light pilot
with match.

3.

Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob. Now
follow step 9, on page 14.

MANUAL LIGHTING

PROCEDURE

The thermostat control setting on the
remote control unit can be set to any
comfort level between HI and LO. The
burners will turn on and off automati-
cally to maintain the comfort level you
select. The ideal comfort setting will vary
by household depending upon the amount
of space to be heated, the output of the
central heating system, etc.

HAND HELD REMOTE

OPERATION

NOTICE: You must light the pilot
before using the hand-held re-
mote control unit. See 

Lighting

Instructions on page 14.

1.

After lighting, let pilot flame burn for
about one minute. Turn control knob
to ON position. Adjust flame adjust-
ment knob anywhere between HI
and LO. Slide the remote selector
switch to the REMOTE position. The
burners will come on. You can now
turn the burners on and off with the
hand-held remote control unit.

IMPORTANT:

  Do not leave the re-

mote selector switch in the REMOTE
position when the pilot is not lit. This
will drain the battery.

2.

Select the MANUAL or AUTO but-
ton on the hand-held remote control
unit.
• In MANUAL mode, turn burners

on or off by pressing the ON or
OFF buttons on the hand-held re-
mote control unit.

• In AUTO mode, the room tempera-

ture is controlled by the thermo-
stat in the hand-held remote con-
trol unit. To increase the room tem-

O

FF

PIL

O

T

O

N

LO

IH

REMOTE
OFF
ON

Figure 26 - Setting the Remote Selector Switch, Control Knob, and Flame Adjustment
Knob for Remote Operation

Remote Selector Switch in Remote Position

Control Knob in
On Position

Flame Adjustment Knob

perature, press the top arrow of the
TEMP button. To lower room the
temperature, press the bottom ar-
row to the TEMP button. At higher
settings the heater will run more.

IMPORTANT:

  The hand-held re-

mote control unit must be near the
heater. Do not keep the hand-held
remote control unit too close the
heater. The thermostat on the
hand-held remote control unit will
heat up too quickly and turn the
heater off.

3.

Use the STATUS button on the hand-
held remote control unit to see the
operation mode being used and the
temperature setting selected. A red
light will come on beside the opera-
tion mode being used when the sta-
tus button is pressed.

4.

To turn the burners off when oper-
ating in the MANUAL mode, press
the OFF button. If operating in the
auto mode, press the manual button,
then press the OFF button The pilot
will remain lit.

IMPORTANT:

  To turn the pilot off,

manually turn the control knob on the
heater to the OFF position or set re-
mote selector switch to OFF position.

TEMP

STATUS

HI

LO

MAN

ON

AUTO

OFF

Increases Room
Temperature

Decreases Room
Temperature

Turns Burners
On and Off

Shows Current
Operation Mode

The log heater will
automatically cycle
between pilot and the
heat setting that has
been selected.

Shows Temperature
Setting

Allows Burners to be
Turned On and Off
with the Hand-Held
Remote Unit.

Figure 27 - Thermostat Hand-Held Remote Control Unit Selections

Содержание Comfort Glow GCF26PR

Страница 1: ...tstoreorusegasolineorotherflammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch d...

Страница 2: ...oting Do not add lava rock around base Rock and debris could fall into the control area of fireplace 8 You must operate this fireplace with the fireplace screen in place Make sure fireplace screen is...

Страница 3: ...2 Remove all protective packaging ap plied to fireplace for shipment 3 Make sure your fireplace includes one hardware packet and one remote con trol packet which includes batteries 4 Checkfireplacefor...

Страница 4: ...sup port see Figure 2 The log should fit flat against top of burner support Place two 10 one inch long screws through burner support into the log and tighten Place branches on branch support see Figu...

Страница 5: ...ntila tion grills between them WARNING This heater shall notbeinstalledinaconfinedspace or unusually tight construction unless provisions are provided foradequatecombustionandven tilation air Read the...

Страница 6: ...vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used ___________ B...

Страница 7: ...igure 4 Ventilation Air from Inside Building Shown with Optional Mantel VENTILATION AIR Ventilation Air From Inside Building Thisfreshairwouldcomefromanadjoining unconfined space When ventilating to a...

Страница 8: ...6 inches from the front top or sides of the fireplace as a fireplace insert in high traffic areas in windy or drafty areas IMPORTANT Vent freefireplacesaddmois ture to the air Although this is benefic...

Страница 9: ...connect blower to electrical source Option one Route blower electrical cord through side or rear access door of fireplace Plug electrical cord into electrical outlet 1 Frame in rough opening Use dime...

Страница 10: ...irebox assembly Blower accessory should be installed if it is being used see Accesso ries page 21 1 Unscrew four brass screws that attach top louver to fireplace Remove louvre from fireplace and set a...

Страница 11: ...male threads This will prevent excess sealant from going into pipe Excess sealant in pipe could result in clogged fireplace valves Installsedimenttrapinsupplylineasshown in Figure 17 Locate sediment t...

Страница 12: ...ovided to allow accessibility fromthefireplace seeFigure19 The flexible gas supply line con nection to the manual shutoff valve should be accessible Branch Support Screen Screen Shipping Screw Shoulde...

Страница 13: ...ect all leaks at once 6 Light fireplace see Operating Fire place pages 14 and 15 Check all other internal joints for leaks 7 Turn off fireplace see To Turn Off Gas to Appliance page 15 8 Replace front...

Страница 14: ...itor button This will light pilot The pilot is attached to the front burner If needed keep press ing ignitor button until pilot lights Note If pilot does not stay lit con tact a qualified service pers...

Страница 15: ...2 Select the MANUAL or AUTO but ton on the hand held remote control unit In MANUAL mode turn burners on or off by pressing the ON or OFF buttons on the hand held re mote control unit InAUTO mode the r...

Страница 16: ...nal replacement part s callDESAInternational sTechnical Service Department at 1 800 323 5190 for referral information When calling DESA International have ready your name your address model number of...

Страница 17: ...ODS pilot 5 Thermocouple connection loose at con trol valve 6 Thermocouple damaged 7 Control valve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep...

Страница 18: ...r a few hours of operation 1 Refer to Air for Combustion and Venti lation requirements page 5 1 Turn control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from...

Страница 19: ...st after burner is lit or shut off Heater produces unwanted odors Heater shuts off in use ODS operates Gas odor even when control knob is in OFF position Gas odor during combustion REMEDY 1 This is co...

Страница 20: ...1348 Dixwell Avenue Hamden CT 06514 0322 1 800 397 7553 203 248 7553 Parts Department Portable Heater Parts 342 N County Rd 400 East Valparaiso IN 46383 9704 All States 219 462 7441 1 800 362 6951 Par...

Страница 21: ...mantel andhearthbasecornerdesignfeaturesclean classic lines Available in a walnut finish or an unfinished hardwood ready to stain or paint Complete assembly instructions in cluded Three sided brass tr...

Страница 22: ...GCF26PR ILLUSTRATED PARTS BREAKDOWN CGCF26PR 11 11 AU TO MA N OF F ST AT US ON LO HI TE MP 29 30 38 38 7 35 26 36 10 40 40 7 24 1 2 8 15 6 21 31 32 13 18 22 5 27 20 19 16 28 1 28 2 23 39 14 25 33 34 1...

Страница 23: ...Base 1 16 102649 02CJ Branch Support 1 17 097159 04 Piezo 1 18 099387 13 Pilot Tube 1 19 098271 07 Ignitor Cable 1 20 098251 03 Injector 1 21 098250 01 Injector Holder 1 22 098249 01 Nut M5 6 23 1037...

Страница 24: ...caused by improper installation Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective fireplace will be the responsibility of the owner TO THE F...